UNIVERSIDADE FEDERAL DA BAHIA FACULDADE DE ODONTOLOGIA

Tamanho: px
Começar a partir da página:

Download "UNIVERSIDADE FEDERAL DA BAHIA FACULDADE DE ODONTOLOGIA"

Transcrição

1 UNIVERSIDADE FEDERAL DA BAHIA FACULDADE DE ODONTOLOGIA CENTRO DE ORTODONTIA E ORTOPEDIA FACIAL PROF. JOSÉ ÉDIMO SOARES MARTINS AVALIAÇÃO DE ADESIVO AUTO-CONDICIONANTE E DE ADESIVO HIDROFÍLICO NA COLAGEM DE BRACKETS COM PRESENÇA OU AUSÊNCIA DE CONTAMINAÇÃO SALIVAR CRISTIANE BECHER ROSA CD SALVADOR 2006

2 AVALIAÇÃO DE ADESIVO AUTO-CONDICIONANTE E DE ADESIVO HIDROFÍLICO NA COLAGEM DE BRACKETS COM PRESENÇA OU AUSÊNCIA DE CONTAMINAÇÃO SALIVAR CRISTIANE BECHER ROSA CD Orientador: Prof. Roberto Amarante Costa Pinto Co-Orientador: Prof. Fernando Antonio Lima Habib Dissertação apresentada à Faculdade de Odontologia da Universidade Federal da Bahia como parte dos requisitos para obtenção do título de Especialista em Ortodontia. Comissão Examinadora: Profa. Myrela Galvão Prof. Gildo Coelho Profa. Lucianna Gomes SALVADOR 2006

3 Ficha Catalográfica R788 Rosa, Cristiane Becher. Avaliação de adesivo auto-condicionante e de adesivo hidrofílico na colagem de brackets com presença ou ausência de contaminação salivar. Salvador, f. Dissertação (Especialização em Ortodontia) Faculdade de Odontologia UFBA, Orientador: Prof. Roberto Amarante Costa Pinto Co-Orientador: Prof. Fernando Antonio Lima Habib 1. Colagem dentária. 2. Saliva. 3. Adesivos dentinários. 4.Esmalte dentário I. Universidade Federal da Bahia Faculdade de Odontologia. II. Título CDU:

4 Aos meus pais, Adalberto e Teresinha, e ao meu irmão, Marcelo, pelo carinho, apoio e incentivo. Dedico.

5 AGRADECIMENTOS Ao professor Dr. Roberto Amarante Costa Pinto pela atenção, dedicação e orientação na realização deste trabalho. Ao professor Dr. Fernando Antonio Lima Habib pela atuação como co-orientador e pelos ensinamentos durante todo o curso. À coordenadora e professora Dra. Telma Martins de Araújo pelo exemplo, determinação e conhecimentos transmitidos. À todos os professores do departamento de Ortodontia da Faculdade de Odontologia da UFBA pela seriedade que dedicam ao curso. Ao professor Dr. Gildo Coelho, do departamento de Odontologia Restauradora da UFBA, que gentilmente colocou à disposição a máquina de cisalhamento para o ensaio mecânico e forneceu instruções sobre seu uso. Ao professor Dr. Silvio Albergaria, do departamento de Odontologia Restauradora da UFBA, que gentilmente colocou à disposição a estufa para armazenamento da amostra. À professora Dra. Cristina Cangussu, do departamento de Pós-Graduação em Odontologia da UFBA, pela execução da análise estatística. Aos colegas de turma (Adriana Libório, Érika Guanaes, Déborah Rossetti, Mauro Henrique Nascimento e Thiago Vinhas) pelo companheirismo e espírito de união. À todos os outros alunos que compartilharam comigo os dois anos do curso de especialização. Aos funcionários do departamento de Ortodontia da Faculdade de Odontologia da UFBA pela amizade. À Morelli pela doação dos brackets usados nesta pesquisa.

6 RESUMO Neste trabalho foi verificada a resistência ao cisalhamento da colagem ortodôntica com uso de um adesivo auto-condicionante (Transbond Self-Etching Primer Transbond SEP), de um adesivo hidrofílico (Transbond Moisture-Insensitive Primer - MIP) e sem uso de adesivo, na presença ou na ausência de contaminação salivar. Foram usados dentes bovinos (80) divididos em 8 grupos: (1) controle sem contaminação salivar, (2) controle com contaminação salivar, (3) Transbond SEP (sem contaminação salivar), (4) Transbond SEP (contaminação salivar antes do adesivo), (4) Transbond SEP (reaplicado após contaminação salivar), (6) MIP (sem contaminação salivar), (7) MIP (contaminação salivar antes do adesivo) e (8) MIP (reaplicado após contaminação salivar). Brackets metálicos foram colados com compósito (Transbond XT). Os corpos de prova foram armazenados a 37º± 1º C até a realização do teste de cisalhamento. Diferença estatística foi determinada com valor de probabilidade de 0.05 ou menos (p 0.05). Em superfícies de esmalte não contaminadas foi constatado não haver a necessidade da aplicação de adesivo para se obter uma adequada resistência ao cisalhamento (média 8,98 ± 4,64 MPa). A colagem na presença de saliva sem o uso de adesivo resultou, no entanto, em uma resistência ao cisalhamento (média 3,2 ± 2,84 MPa) menor que o mínimo requerido para uma resistência satisfatória. O adesivo hidrofílico apresentou resultados similares quanto à resistência ao cisalhamento na presença ou na ausência de contaminação salivar (p>0.05). O adesivo auto-condicionante obteve maior resistência na presença de saliva (p<0.05). Na colagem em esmalte sem contaminação salivar o adesivo hidrofílico mostrou maior resistência ao cisalhamento do que o auto-condicionante (p=0.001). Nenhuma diferença quanto à resistência ao cisalhamento foi encontrada, no entanto, ao se usar esses adesivos em superfícies contaminadas por saliva (p=0.352). A contaminação salivar da primeira camada de adesivo, seguida da reaplicação do mesmo, também resultou em adequada resistência ao cisalhamento para ambos os adesivos (p=0.567).

7 SUMMARY The purpose of this study was to verify the shear bond strength of orthodontic bonding with a self-etching primer (Transbond Plus Self-etching Primer Transbond SEP), a hydrophilic primer (Transbond Moisture-Insensitive Primer - MIP) and without a primer application, in the presence or absence of saliva contamination. Bovine teeth (80) were divided into 8 groups: (1) control without primer (uncontaminated), (2) control without primer (saliva contaminated), (3) Transbond SEP (uncontaminated), (4) Transbond SEP (saliva contaminated before primer), (5) Transbond SEP (reapplied after saliva contamination), (6) MIP (uncontaminated), (7) MIP (saliva contaminated before primer) e (8) MIP (reapplied after saliva contamination). Stainless steel brackets were bonded with composite resin (Transbond XT). All samples were stored in 37º± 1º C until the shear bond strength test. Significance for statistics was predetermined at a probability value of 0.05 or less (p 0.05). Under uncontaminated enamel surfaces the application of a primer is unnecessary to obtain adequate shear bond strengths (mean 8.98 ± 4.64 MPa). The presence of saliva in bonding procedures without the use of a primer, however, resulted in shear bond strength lower than the minimal required for a satisfactory bonding (mean 3.2 ± 2.84 MPa). The hydrophilic primer presented comparable shear bond strength results in the presence or absence of saliva contamination (p>0.05). The self-etching primer obtained higher strength in the presence of saliva (p<0.05). Comparing the hydrophilic primer to the self-etching primer in uncontaminated enamel surfaces, higher shear bond strength was observed with the use of the hydrophilic primer (p=0.001). No difference was found though between these primers in salivary contaminated surfaces (p=0.352). Initial primer application contaminated by saliva, followed by reapplication of the primer, also resulted in adequate shear bond strengths for both primers (p=0.567).

8 LISTA DE FIGURAS Página Figura 1 Dispositivo usado no experimento 22 Figura 2 Corpo de prova no dispositivo 23 Figura 3 - Colagem dos brackets 27 Artigo 1 Figure 1 - Bracket Bonding 45 Artigo 2 Figure 1 - Bracket Bonding 62

9 LISTA DE QUADROS Página Quadro 1 - Grupos da Amostra 25

10 LISTA DE TABELAS Página Artigo 1 Table 1 - Descriptive statistics 41 Table 2 - Student t test comparing the shear bond strength between the Transbond SEP groups 42 Table 3 - Student t test comparing the shear bond strength between the MIP groups 43 Table 4 - Student t test comparing the shear bond strength between the Transbond SEP and MIP groups used in same enamel conditions 44 Artigo 2 Table 1 - Descriptive statistics 59 Table 2 - Student t test comparing the shear bond strength between Control, Transbond SEP and MIP groups on enamel without saliva contamination 60 Table 3 - Student t test comparing the shear bond strength between Control, Transbond SEP and MIP groups on enamel with saliva contamination 61

11 ÍNDICE Página 1. INTRODUÇÃO PROPOSIÇÃO ABORDAGEM EXPERIMENTAL DESENVOLVIMENTO SEQUENCIAL DA PESQUISA 4.1 ARTIGO ARTIGO DISCUSSÃO CONCLUSÃO REFERÊNCIAS BIBLIOGRÁFICAS 75

12 11 1. INTRODUÇÃO A substituição da cimentação de bandas de aço inoxidável e ouro pela colagem de brackets é considerada um dos maiores avanços no campo da ortodontia (SILVERMAN et al, 1995). A introdução da técnica do condicionamento ácido do esmalte por Buonocore em 1955 tornou possível a colagem direta de brackets e acessórios ortodônticos (ALJUBOURI, MILLETT & GILMOUR, 2003; VELO, CARANO & CARANO, 2002). Há relatos de que a primeira colagem de brackets ortodônticos ocorreu na década de 50 por Newman (NEWMAN, 1992), seguido por Mitchell (MITCHELL, 1992) e Cueto (CUETO, 1990) na década de 60. A colagem ortodôntica possibilita maior conforto e estética, melhor controle de placa, assim como diminui a irritação gengival e o tempo de cadeira do paciente (SCHANEVELDT & FOLEY, 2002; GRANDHI, COMBE & SPEIDEL, 2001; SOUZA, FRANCISCONI & ARAÚJO, 1999). O sucesso na técnica de colagem, porém, requer conhecimento de princípios ortodônticos e de dentística (ZACHRISSON, 2002). Os compósitos convencionais demandam um campo operatório seco e isolado para se obter uma adesão clinicamente aceitável (WEBSTER et al, 2001). Manter a superfície do esmalte completamente livre de contaminação por umidade, todavia, é difícil, principalmente na colagem de brackets e acessórios durante procedimentos cirúrgicos de dentes impactados, em superfícies dentárias linguais (ITOH et al,1999; MORAES et al, 1998), em segundos molares e em dentes parcialmente erupcionados (CACCIAFESTA et al, 2003; GRANDHI, COMBE & SPEIDEL, 2001). A contaminação por umidade, seja por saliva, sangue, água ou fluido gengival, reduz a força de adesão significativamente e é considerada a razão mais comum para falhas na colagem com compósitos (ZEPPIERI, CHUNG & MANTE, 2003). De forma semelhante, a contaminação do esmalte por óleo proveniente do compressor de ar da seringa tríplice também reduz a penetração do material adesivo durante a colagem (DIEDRICH, 1981).

13 12 No processo de adesão entre esmalte e compósito, uma etapa essencial é o condicionamento ácido do esmalte (VELO, CARANO & CARANO, 2002). O ácido mais utilizado é o fosfórico em uma concentração que varia de 30 a 50%, sendo a concentração de 37% a mais empregada (ANUSAVICE, 1998). Quanto ao tempo de condicionamento, 15 segundos são suficientes para produzir uma força de adesão satisfatória e preservar a estrutura de esmalte (ANUSAVICE, 1998). No entanto, através da microscopia eletrônica de varredura observou-se que o condicionamento com ácido fosfórico a 37% por 30 segundos produz um melhor padrão de condicionamento do que se usar apenas 15 segundos (JOHNSTON, HUSSEY & BURDEN, 1996; POWERS & MESSERSMITH, 2001). O condicionamento ácido tem como subprodutos o monofosfato de cálcio e o sulfato de cálcio, que devem ser removidos (POWERS & MESSERSMITH, 2001). Desta forma, após a aplicação do ácido a superfície dentária deve ser lavada abundantemente com água por pelo menos 20 segundos para assegurar a completa remoção dos subprodutos da reação e do mineral solubilizado na superfície (CARVALHO et al, 2004). O condicionamento ácido promove a dissolução dos centros e/ou da periferia dos prismas de esmalte (ANUSAVICE, 1998). Isto cria microporosidades e uma alta energia de superfície neste tecido, favorecendo a penetração da resina para formação dos tags que proporcionam uma retenção mecânica desta no esmalte (GRANDHI, COMBE & SPEIDEL, 2001). Resultados de estudos in vitro demonstram, no entanto, que a umidade ou contaminação salivar do esmalte após condicionamento ácido resulta em uma diminuição do número e tamanho das projeções de resina (KOMATSU, 1980). Apenas um segundo de contato da saliva com o esmalte condicionado é suficiente para a formação de uma camada aderente de material orgânico, que não é removida com lavagem e secagem do esmalte. O esmalte condicionado promove sítios reativos de íons de cálcio e fosfato, aos quais por atração eletrostática as proteínas salivares se ligariam, impedindo a penetração do adesivo em seus poros. A adesão entre o esmalte e a resina estaria então comprometida, possibilitando fraturas adesivas (SILVERSTONE, HICKS & FEATHERSTONE, 1985), ou seja, fraturas na interface dente/adesivo (POWERS, KIM & TURNER, 1997). Desta forma, seria indicado um recondicionamento ácido após a contaminação salivar (SILVERSTONE, HICKS & FEATHERSTONE, 1985).

14 13 Unidades dentárias com compósito aplicado diretamente na superfície de esmalte, previamente contaminado com saliva e recondicionado por 10 ou 60 segundos, não apresentaram diferença quanto à resistência ao cisalhamento, sugerindo que 10 segundos de recondicionamento ácido seriam suficientes para descontaminação da superfície (HORMATI, FULLER & DENEHY, 1980). Um recondicionamento de 10 segundos da superfície dentária contaminada, porém, promove a remoção de quase todos os precipitados da saliva, mas não consegue restabelecer o padrão de condicionamento encontrado em esmalte não contaminado, porque o recondicionamento remove uma certa camada de esmalte. Assim, há uma maior perda de estrutura dentária, a qual, sempre que possível, deve ser evitada, e maior possibilidade de fratura na descolagem (MENEZES, 1993). Realizado o condicionamento ácido segue-se com a lavagem e secagem da superfície dentária, que é considerada uma etapa difícil tanto para o paciente quanto para o profissional devido à necessidade de se manter o esmalte condicionado livre de contaminação (IRELAND, KNIGHT & SHERRIFF, 2003). Um campo operatório livre de contaminação salivar ou sanguínea é uma exigência da maioria dos adesivos para se obter uma adesão adequada (ZEPPIERI, CHUNG & MANTE, 2003; ITOH et al,1999). Toda colagem ortodôntica envolve no mínimo duas interfaces: esmalte/compósito e bracket/compósito. Se um adesivo é utilizado, outra interface, a do adesivo/compósito, é formada (POWERS, KIM & TURNER, 1997). Os adesivos dentais são compostos de monômeros resinosos de diferentes pesos moleculares e viscosidades. A adequada fluidez dos adesivos é obtida através da adição de diluentes resinosos, solventes orgânicos como acetona e etanol, e água. Os adesivos podem ser classificados de acordo com sua estratégia adesiva. Desta forma podem ser divididos em adesivos convencionais e adesivos auto-condicionantes (CARVALHO et al, 2004). Os adesivos convencionais podem ser divididos em duas categorias, de acordo com o número de passos operatórios envolvidos, sendo classificados como de três ou dois passos. Os adesivos de três passos apresentam a aplicação separadamente do ácido condicionante, do primer e do adesivo. Os adesivos de dois passos apresentam a aplicação do condicionamento ácido de forma isolada, seguida da aplicação de uma única solução denominada primer/adesivo, que é a mistura do primer hidrofílico com monômeros resinosos hidrofóbicos do adesivo. Os adesivos

15 14 convencionais, sendo assim, representam os sistemas que empregam o passo do condicionamento ácido do esmalte ou dentina separadamente dos outros passos (CARVALHO et al, 2004). Dentre os adesivos convencionais estão os agentes adesivos hidrofílicos para fins restauradores, com acetona ou etanol como solventes, que hipoteticamente seriam capazes de se deslocar e se difundir através do filme salivar para atingir a hidroxiapatita e promover uma adesão adequada após a polimerização. Estudos indicam que a adesão ao esmalte contaminado é significativamente afetada se a saliva for removida somente através de jato de ar, pois uma camada de proteína salivar seca se formaria sobre o esmalte, impedindo o contato entre este e o adesivo. Caso o esmalte contaminado seja lavado e seco com bolinha de algodão, porém, haveria ainda a presença de água no filme salivar, facilitando a penetração dos monômeros dissolvidos no solvente de acetona. Assim, os sistemas adesivos convencionais de dois passos seriam relativamente insensíveis à contaminação salivar, eliminando a necessidade de recondicionamento ácido (FRITZ, FINGER & STEAN, 1998). Os adesivos hidrofílicos têm sido utilizados principalmente nos procedimentos restauradores para se obter adesão dentinária. Atualmente adesivos hidrofílicos para uso em esmalte foram desenvolvidos com objetivo de produzir adesão adequada, havendo ou não a presença de umidade (WEBSTER et al, 2001). O Transbond Moisture-Insensitive primer (MIP 3M Unitek) é um adesivo hidrofílico insensível à umidade, que apresenta entre outros componentes o Bis-GMA, o 2- hidroxietilmetacrilato (HEMA), o etanol e a água, sendo estes dois últimos solventes. De acordo com o fabricante, pode ser usado em superfícies de esmalte condicionado com ou sem a presença de saliva ou água, sem comprometer a força de adesão, sendo compatível com compósitos auto ou fotopolimerizáveis. A resistência ao cisalhamento com o uso do adesivo MIP em superfícies contaminadas com água ou saliva usando compósitos auto (Concise) e fotopolimerizavéis (Transbond XT) foi testada em um estudo recente. O adesivo não foi fotopolimerizado antes da aplicação da resina auto-polimerizável, apesar das instruções do fabricante. A maior resistência em ambiente úmido foi obtida com o uso do MIP associado ao compósito Transbond XT, que ao ser polimerizado promoveu a fotopolimerização do adesivo simultaneamente. A influência da fotopolimerização do MIP na resistência ao cisalhamento antes da aplicação do compósito autopolimerizável não foi testada (GRANDHI, COMBE & SPEIDEL, 2001).

16 15 Em superfícies de esmalte sem contaminação salivar o adesivo hidrofílico MIP apresentou maior resistência ao cisalhamento que o grupo controle com o adesivo hidrofóbico Transbond XT (WEBSTER et al, 2001). Em outros estudos a resistência ao cisalhamento do adesivo MIP em relação ao adesivo XT, quando usados em superfícies secas, não diferiu estatisticamente (KULA, NASH & PURK, 2003; ZEPPIERI, CHUNG & MANTE, 2003; GRANDHI, COMBE & SPEIDEL, 2001). Resultados indicam que a contaminação salivar, no entanto, reduz significativamente a resistência do MIP quando comparada à sua resistência em ambiente seco (ZEPPIERI, CHUNG & MANTE, 2003). Em outra avaliação, nenhuma diferença foi encontrada entre a resistência do MIP usado em superfície seca ou úmida. No entanto, os resultados indicam que a resistência do MIP em ambiente úmido é estatisticamente superior à resistência do adesivo Transbond XT na mesma condição. A área da fratura do compósito associado ao adesivo MIP se apresentou na interface compósito/bracket ou no interior do compósito, indicando que o MIP foi capaz de penetrar ou deslocar a umidade e produzir uma adesão adequada. Este efeito pode estar relacionado com a presença do etanol como solvente, assim como com a presença do HEMA na composição do MIP, já que há relatos de ambos contribuírem para uma melhor adesão em superfícies úmidas. (KULA, NASH & PURK, 2003). Outra pesquisa, porém, determinou que quando a contaminação salivar ocorria antes da aplicação do adesivo MIP as falhas entre este e o esmalte eram mais freqüentes, sugerindo uma penetração incompleta do adesivo. Já nos grupos em que a contaminação salivar ocorreu após a aplicação do adesivo com reaplicação deste, as falhas foram localizadas na interface bracket/adesivo (SCHANEVELDT & FOLEY, 2002). A reaplicação do MIP após a contaminação da primeira camada do adesivo por saliva aumenta sua resistência ao cisalhamento para valores estatisticamente semelhantes ao do grupo controle com o adesivo Transbond XT sem contaminação (SCHANEVELDT & FOLEY, 2002). Outro sistema adesivo aplicado nos procedimentos de colagem ortodôntica é o adesivo auto-condicionante ou self-etching primer (SEP), que foi introduzido na dentística para ser usado em restaurações de compósito em esmalte e dentina (ZEPPIERI, CHUNG & MANTE, 2003). Os sistemas adesivos auto-condicionantes possuem monômeros resinosos ácidos em sua composição que simultaneamente desmineralizam e penetram no substrato dental sem a

17 16 necessidade da aplicação isolada de um ácido para produzir as porosidades nos tecidos dentais. Devido à presença dos monômeros, estes sistemas não devem ser lavados após a aplicação. Os adesivos auto-condicionantes também podem ser classificados de acordo com o número de passos operatórios em sistemas de um ou dois passos (CARVALHO et al, 2004). Nos sistemas de dois passos foram associados o primer e o ácido condicionante através da adição de ésteres fosfatados aos grupamentos carboxílicos de monômeros resinosos, acidificandoos para que estes promovessem a desmineralização do esmalte e da dentina. O segundo passo é a aplicação de um adesivo hidrofóbico (CARVALHO et al, 2004). Os adesivos auto-condicionantes de um passo uniram o primer ácido com a resina adesiva do sistema convencional de dois passos. Desta forma uma única solução desempenha a função de desmineralização, infiltração e posterior ligação com o material restaurador (CARVALHO et al., 2004). O SEP com finalidade ortodôntica, Transbond Plus Self-Etching Primer (Transbond SEP 3M Unitek), de acordo com o fabricante, pode ser utilizado em superfícies de esmalte seco ou úmido, sendo compatível apenas com compósitos fotopolimerizáveis. O uso do Transbond SEP com resinas auto-polimerizáveis não é recomendado pelo fabricante devido a uma redução na força de adesão. Os adesivos auto-condicionantes contêm monômeros ácidos, que ao entrarem em contato com a resina auto-polimerizável reagem com as aminas terciárias, que têm caráter alcalino, consumindo-as e impedindo que atuem como ativadoras do processo de polimerização do compósito (CARVALHO et al, 2004). O uso do Transbond SEP com diversos compósitos, foto e auto-polimerizáveis, foi testado, sendo que a melhor adesão foi obtida com o uso do compósito fotopolimerizável Transbond XT como indicado pelo fabricante (ROMANO et al, 2005). Adesivos auto-condicionantes de um passo, como o Transbond SEP, apresentam uma embalagem com três compartimentos para ser utilizado, de acordo com o fabricante, individualmente em cada paciente, evitando conseqüentemente contaminação cruzada (BUYUKYILMAZ, USUMEZ & KARAMAN, 2003). No primeiro se encontra o éster fosfórico metacrilato, fotoiniciadores e estabilizadores; no segundo compartimento está a água e o complexo fluorídrico; e no último reservatório se encontra o aplicador (ALJUBOURI, MILLETT & GILMOUR, 2003). Segundo o fabricante, cada aplicador tem quantidade suficiente de adesivo

18 17 para ser usado em todos os dentes de uma arcada. As vantagens do SEP incluem ainda um menor número de passos na técnica de adesão que resultaria em menor número de erros, economia de tempo (ALJUBOURI, MILLET & GILMOUR, 2003; ZEPPIERI, CHUNG & MANTE, 2003; BISHARA et al, 2001), maior conforto ao paciente e maior controle de umidade (IRELAND, KNIGHT & SHERRIFF, 2003). Ao se usar os sistemas de adesivos auto-condicionantes ClearFil SE Bond, Etch & Prime 3.0 e Non Rinse Conditioner + Prime & Bond NT foi observado um tempo de colagem similar entre estes sistemas e o procedimento de colagem com ácido fosfórico (LOPES et al, 2001). O tempo despendido na colagem de brackets ortodônticos com Transbond SEP, no entanto, se apresentou quase 1/3 menor que o tempo usado no procedimento de colagem com a técnica de condicionamento ácido convencional seguida da aplicação de adesivo (ALJUBOURI, MILLET & GILMOUR, 2003). Da mesma forma, outras pesquisas recentes também sugerem o uso do adesivo auto-condicionante Transbond SEP como meio para reduzir o tempo de colagem e ao mesmo tempo fornecer uma adesão adequada (BISHARA et al, 2005; ALJUBOURI, MILLET & GILMOUR, 2004). A fotopolimerização do Transbond SEP simultaneamente à do compósito resultou em força de cisalhamento semelhante à encontrada em unidades com o adesivo e compósito fotopolimerizados separadamente, indicando a possível eliminação de mais uma etapa no procedimento da colagem e reduzindo ainda mais o tempo de cadeira do paciente (AJLOUNI et al, 2004). Na técnica convencional de condicionamento do esmalte com ácido fosfórico, o cálcio é seletivamente dissolvido da estrutura de esmalte e removido na lavagem da superfície dentária. O SEP tem como composição o éster fosfórico metacrilato, formado pela combinação de um grupo metacrilato e o ácido fosfórico em uma molécula que promove o condicionamento ácido e o recobrimento da superfície dentária com adesivo simultaneamente. O grupo fosfato do éster fosfórico metacrilato dissolve e remove o cálcio da hidroxiapatita. O cálcio forma um complexo com o grupo fosfato e é incorporado na rede quando o adesivo polimeriza. O grupo ácido é neutralizado quando reage com o cálcio, não sendo necessária a lavagem do esmalte para remover a substância condicionante (ZEPPIERI, CHUNG & MANTE, 2003). O padrão de condicionamento do esmalte com o adesivo auto-condicionante também ocorre de forma diferente em relação ao condicionamento ácido convencional, sendo

19 18 aparentemente mais superficial. Isto pode estar relacionado com uma menor penetração do adesivo auto-condicionante ou ser resultado de uma interferência de precipitado de cálcio na superfície do esmalte, mascarando o padrão de condicionamento. A alta concentração de íons de cálcio e fosfato liberados do esmalte pelo condicionamento com este adesivo limita a continuação da dissolução da hidroxiapatita e conseqüentemente limita a profundidade da desmineralização do esmalte (DORMINEY, DUNN & TALOUMIS, 2003). No entanto, em outro estudo, ao comparar a desmineralização do esmalte produzido pelo Transbond SEP e a produzida pelo ácido fosfórico a 35% através da microscopia eletrônica de varredura observou-se uma similaridade entre o padrão de condicionamento dos dois grupos (LOPES et al, 2003). Resultados de um estudo demonstraram que o Transbond SEP em condições ideais apresentou resistência ao cisalhamento maior que o adesivo hidrofóbico Transbond XT com condicionamento ácido convencional (BUYUKYILMAZ, USUMEZ & KARAMAN, 2003). Ao se avaliar a atuação de adesivos auto-condicionantes aplicados em superfícies de esmalte contaminadas por saliva antes ou após a aplicação do adesivo, observou-se uma resistência ao cisalhamento satisfatória. Caso a contaminação, no entanto, ocorra duas vezes, antes e após a aplicação do adesivo, a força de cisalhamento é reduzida, indicando que quanto maior a contaminação salivar durante o procedimento de colagem, maior a redução da adesão (BISHARA et al, 2002b). Em condições ideais, sem contaminação do esmalte, estudos indicam que os adesivos Transbond XT e Transbond MIP apresentam resistência ao cisalhamento maior que o Transbond SEP (ALJUBOURI, MILLET & GILMOUR, 2003; ZEPPIERI, CHUNG & MANTE, 2003). Já em superfícies contaminadas com saliva antes ou após a aplicação do adesivo com reaplicação deste, o Transbond SEP apresentou resultados satisfatórios. Apesar da resistência ao cisalhamento do SEP ter sido menor em superfícies secas, a resistência obtida ainda foi considerada clinicamente aceitável pelo autor por estar acima de 5 MPa (ZEPPIERI, CHUNG & MANTE, 2003). O uso destes agentes adesivos, convencionais ou auto-condicionantes, formulados para serem aplicados em ambientes secos ou úmidos, eliminando até mesmo algumas etapas durante os procedimentos de colagem, possibilitaria uma economia de tempo de atendimento aos pacientes e principalmente uma maior segurança de que uma colagem ortodôntica satisfatória seria obtida.

20 19 Os adesivos podem aumentar a adesão na colagem, diminuindo o número de descolagens durante o tratamento ortodôntico. O resultado disto é um maior número de falhas na interface esmalte/compósito, com conseqüente aumento do índice de fraturas de esmalte (BISHARA et al, 2002a; MENEZES, 1991). A superfície entre o compósito e o bracket, no entanto, é o local de quebra preferível quando este é removido (PROFFIT & FIELDS, 2002). Uma menor quantidade de compósito na superfície dentária pode ser uma vantagem, por facilitar o processo de limpeza do dente (BISHARA et al, 1998), mas deve-se lembrar que a integridade do esmalte precisa ser preservada ao serem removidos os brackets e os acessórios ortodônticos (BISHARA et al, 2002a; MENEZES, 1991). O ideal seria minimizar a perda de esmalte dentário nos estágios de colagem, descolagem e remoção de compósito residual, permanecendo a superfície dentária com grau de rugosidade original do dente (HOSEIN, SHERRIF & IRELAND, 2004). A necessidade da aplicação de um adesivo na colagem ortodôntica tem sido questionada (MENEZES, 1991; FARQUHAR, 1986; JASSEM, RETIEF & JAMISON, 1981). O ortodontista, da mesma forma, ao optar pelo uso de um adesivo, muitas vezes apresenta dúvidas em relação a qual adesivo escolher, especialmente em situações onde o risco de contaminação salivar é evidente. No presente estudo foi avaliada, in vitro, a resistência ao cisalhamento de dois adesivos, tanto em ambiente seco como em ambiente contaminado por saliva, comparando-se então a efetividade de ambos com a resistência de brackets colados sem uso de adesivo.

21 20 2. PROPOSIÇÃO Avaliar: 2.1. A resistência ao cisalhamento de brackets colados em superfícies de esmalte contaminadas ou não por saliva sem uso de adesivo A resistência ao cisalhamento de brackets colados em superfícies de esmalte contaminadas ou não por saliva antes da aplicação dos adesivos Transbond Plus Self-Etching Primer e Moisture-Insensitive Primer A resistência ao cisalhamento de brackets colados em superfícies de esmalte com contaminação salivar após aplicação dos adesivos Transbond Plus Self-Etching Primer e Moisture-Insensitive Primer, seguida de uma reaplicação dos mesmos.

22 21 3. ABORDAGEM EXPERIMENTAL Foram utilizados na amostra 80 dentes bovinos. Os dentes foram extraídos, limpos e armazenados em solução aquosa de timol a 0,1% (CACCIAFESTA et al, 2003; BISHARA et al, 2001; CAMPISTA, 2001), em temperatura ambiente até a realização do experimento Seleção e limitação da área de colagem Antes dos procedimentos de colagem, a amostra foi preparada para possibilitar o ensaio de cisalhamento. Foi necessário determinar a área de colagem na coroa das unidades dentárias para que esta área fosse aplainada. A seleção da área de colagem na superfície vestibular do esmalte foi feita utilizando-se um paquímetro. A altura da coroa clínica de cada dente foi medida com referência na borda incisal e no ponto mais inferior da junção amelo-cementária. A metade desta distância determinou o ponto central da superfície vestibular, que foi a região eleita para colagem e conseqüentemente para o aplainamento dentário. Este ponto central foi marcado com um lápis. Cada unidade dentária foi fixada com cera utilidade (Horus, Dentsply, Rio de Janeiro, RJ) em uma placa de vidro, com a superfície da placa isolada com vaselina líquida, de forma que somente o ponto central da coroa, previamente determinado, tocasse na placa. Foi posicionado um anel, confeccionado a partir de um tubo de filme fotográfico, sobre a coroa do dente para limitar o escoamento da resina acrílica (Jet, Clássico, São Paulo, SP) que foi vazada no seu interior, promovendo a inclusão da coroa na resina. A face vestibular de cada dente foi parcialmente aplainada com lixa de madeira A180 e lixas de carbureto de silício 220 (3M), 400 e 600 (Norton) fixadas em um cortador de gesso. Os dentes foram aplainados sob irrigação com água. O conjunto resina acrílica e coroa foi lixado o suficiente para expor e aplainar uma área ao redor do ponto central da coroa que fosse compatível com o tamanho do bracket a ser colado.

23 Preparo para o ensaio de cisalhamento Cada dente foi posicionado no centro de um anel de PVC (Akros Fortilit, Joinville, SC) contendo gesso tipo IV (Polidental, Cotia, SP) no seu interior. Os anéis de PVC foram posicionados na plataforma móvel de um dispositivo (TORTAMANO et al, 2002) confeccionado para fixar os anéis de PVC e possibilitar o posicionamento das raízes do dente no gesso (Figura 1). O gesso foi manipulado conforme a orientação do fabricante e vazado no interior do anel de PVC. Figura 1 Dispositivo usado no experimento A coroa de cada dente foi amarrada com um elástico a um esquadro, o qual foi posicionado numa canaleta presente na plataforma fixa do dispositivo, permitindo a fixação do dente no gesso com a face vestibular perpendicular à base do anel de PVC, conforme mostrado na Figura 2. Após a presa do gesso, os corpos de prova foram armazenados em recipientes sob refrigeração em ambiente úmido.

24 23 Figura 2 Corpo de prova no dispositivo 3.3.Preparo das superfícies para colagem Foi realizada profilaxia com pedra-pomes e taça de borracha em baixa rotação por 10 segundos (CACCIAFESTA et al., 2003; BISHARA et al., 2002), seguida de lavagem por 20 segundos com água proveniente da seringa tríplice do equipo odontológico e secagem com papel absorvente. As taças de borracha foram substituídas a cada 15 dentes (CAMPISTA, 2001) Manipulação dos materiais Transbond Plus Self-Etching Primer (Transbond SEP) O Transbond SEP (3M Unitek, Monrovia, CA) foi ativado ejetando a solução do primeiro compartimento no segundo e em seguida a mistura foi ejetada para o reservatório do aplicador. A

25 24 aplicação do adesivo foi feita através do aplicador sobre a superfície do esmalte por 5 segundos seguida de um leve jato de ar por 2 segundos conforme indicado pelo fabricante. Cada unidade do Transbond SEP foi utilizada para 3 dentes. Ao se utilizar o Transbond SEP com o compósito fotopolimerizável Transbond XT a fotopolimerização do adesivo foi simultânea à do compósito Moisture-Insensitive Primer (MIP) O esmalte foi previamente condicionado com ácido fosfórico gel a 37% (Alfa Etch Gel, DFL, Rio de Janeiro, RJ) por 30 segundos, seguido de lavagem por 20 segundos com a seringa tríplice e secagem com papel absorvente. O papel absorvente era depositado delicadamente sobre a superfície dentária e removido com auxílio de uma pinça clínica. O MIP (3M Unitek, Monrovia, CA) foi colocado no esmalte com um aplicador, seguido de leve jato de ar por 2 segundos conforme instruções do fabricante. A fotopolimerização do adesivo MIP foi simultânea à do compósito fotopolimerizável Transbond XT Transbond XT (3M Unitek, Monrovia, CA) Este compósito foi aplicado na base do bracket, que foi colado ao dente. O excesso de compósito foi removido com uma lâmina de bisturi e o compósito fotopolimerizado por 10 segundos de cada lado do bracket, totalizando 40 segundos. Foi utilizado um fotopolimerizador de luz fria (ULTRALED XP, Dabi Atlante, Ribeirão Preto, SP). O LED apresenta uma lâmpada com menor degradação e maior vida útil que os fotopolimerizadores com luz halógena, sendo igualmente efetivos na polimerização durante a colagem de brackets (LAYMAN & KOYAMA, 2004). 3.5.Divisão da amostra em grupos Os dentes foram divididos aleatoriamente nos grupos dispostos no Quadro 1.

26 25 QUADRO 1 - Grupos da Amostra Adesivos Compósito Contaminação salivar após a aplicação do Contaminação salivar Superfície sem adesivo e reaplicação antes da aplicação do contaminação do Transbond SEP ou adesivo MIP Controle (Sem Transbond XT Grupo 1 Grupo 2 Adesivo) Transbond SEP Transbond XT Grupo 3 Grupo 4 Grupo 5 MIP Transbond XT Grupo 6 Grupo 7 Grupo Procedimentos de colagem dos grupos Cada grupo foi composto por 10 dentes. Grupo 1 Controle (sem contaminação salivar): o esmalte foi condicionado com ácido fosfórico a 37% (Alfa Etch Gel DFL) por 30 segundos, lavado por 20 segundos e seco com papel absorvente. Foi utilizado o compósito fotopolimerizável Transbond XT, não houve aplicação de adesivo ou contaminação da superfície do esmalte com saliva. Grupo 2 Controle (com contaminação salivar): após o condicionamento ácido, lavagem e secagem, a superfície do esmalte foi contaminada por 15 segundos com saliva humana coletada do próprio pesquisador em um frasco. A coleta da saliva foi realizada no momento de cada colagem a partir de uma hora após as refeições. A saliva foi colocada na superfície de esmalte com um aplicador. Foi utilizado o compósito Transbond XT sem o uso de um adesivo. Grupo 3 Transbond SEP (sem contaminação salivar): foi utilizado Transbond SEP e o compósito Transbond XT e não houve contaminação da superfície do esmalte com saliva. Grupo 4 Transbond SEP (contaminação salivar antes do primer): antes da aplicação do Transbond SEP, a superfície do esmalte foi contaminada por 15 segundos com saliva. Transbond SEP foi aplicado e o Transbond XT utilizado como compósito.

27 26 Grupo 5 Transbond SEP (reaplicado após contaminação salivar): Transbond SEP foi aplicado. A superfície do esmalte foi contaminada por 15 segundos com saliva. Foi reaplicado Transbond SEP e a colagem com o Transbond XT realizada. Grupo 6 MIP (sem contaminação salivar): após condicionamento com ácido fosfórico a 37%, lavagem e secagem da superfície do esmalte, foram aplicados MIP e o compósito Transbond XT, não havendo contaminação da superfície do esmalte com saliva. Grupo 7 MIP (contaminação salivar antes do primer): após condicionamento, lavagem e secagem, a superfície do esmalte foi contaminada por 15 segundos com saliva, o MIP aplicado e a colagem com o Transbond XT realizada. Grupo 8 MIP (reaplicação após contaminação salivar): após condicionamento, lavagem e secagem da superfície do esmalte, o MIP foi aplicado. A superfície do esmalte foi contaminada por 15 segundos com saliva. Houve uma reaplicação do MIP e a colagem com o Transbond XT realizada. 3.7 Colagem dos brackets A colagem dos brackets foi realizada posicionando os corpos de prova na plataforma móvel do mesmo dispositivo usado para a fixação destes nos anéis. Foram utilizados brackets metálicos Edgewise de incisivo central superior para colagem com slot.022 (Morelli, São Paulo, SP, ref ). A área da base do bracket era 14,282 mm 2. O posicionamento dos brackets na superfície dentária em todos os grupos foi realizado com uma pinça de colagem, seguido de um fio retangular.019 x.025 (Morelli, São Paulo, SP, ref ) que foi encaixado no slot do bracket. O fio retangular estava colado em um esquadro de acrílico que foi encaixado, na direção da face vestibular do dente, em uma canaleta presente na plataforma superior fixa do dispositivo (Figura 3). O fio retangular, ao se encaixar no slot do bracket, posicionava o slot perpendicular à base do anel de PVC. Com este fio retangular foi possível aplicar-se uma pressão uniforme por todo o slot e como a superfície do dente era plana, evitou-se o giro do bracket.

28 27 Figura 3 Colagem dos brackets Cada dente foi identificado marcando-se com caneta de retroprojetor no anel de PVC o grupo ao qual pertencia. Após a colagem, os dentes foram armazenados em estufa a 37 o C ± 1 C em ambiente úmido por 4 dias até a realização do ensaio mecânico Ensaio mecânico resistência ao cisalhamento Os corpos de prova foram posicionados na plataforma móvel e fixados no dispositivo (Figura 1). Na base do dispositivo havia um orifício no centro usado para fixar o mesmo à máquina de cisalhamento (Emic DL2000, São José dos Pinhais, PR) com um parafuso. A ponta ativa da máquina de ensaio universal foi posicionada sobre a borda superior do bracket o mais próximo possível do dente, sem tocá-lo.

29 28 Foi iniciada a descolagem dos brackets com a máquina operando a uma velocidade de 1 mm por minuto. A força necessária para descolagem de cada bracket foi registrada. A resistência ao cisalhamento, expressa em Newton (N) foi dividida pela área da base do bracket em metro quadrado (m 2 ), e convertida em Megapascal (MPa) segundo a seguinte fórmula: Força ( N) Resistência ( MPa) = Área ( m ) Os dados obtidos foram em seguida submetidos à análise estatística através do test t de Student.

30 29 4. DESENVOLVIMENTO SEQUENCIAL DA PESQUISA 4.1. ARTIGO 1 Bond Strength comparison of moisture-insensitive primer and self-etching primer with and without saliva contamination. Cristiane Becher Rosa, DDS ª Roberto Amarante Costa Pinto, DDS, MSc b Fernando Antonio Lima Habib, DDS, MSc c ª Postgraduate student, Department of Orthodontics and Dentofacial Orthopedics, Dentistry School, Federal University of Bahia, Salvador, Bahia, Brazil. b Professor, Department of Orthodontics and Dentofacial Orthopedics, Dentistry School, Federal University of Bahia, Salvador, Bahia, Brazil. c Professor, Department of Orthodontics and Dentofacial Orthopedics, Dentistry School, Federal University of Bahia, Salvador, Bahia, Brazil. Correspondence: Dr. Cristiane Becher Rosa, Departamento de Ortodontia, Faculdade de Odontologia da Universidade Federal da Bahia, Av. Araújo Pinho, 62, Canela, CEP Salvador BA, Brazil. Telephone: (55-71) Fax: (55-71) becherrosa@gmail.com

31 30 Abstract: The purpose of this study was to determine the shear bond strength of orthodontic brackets bonded with a hydrophilic (Transbond Moisture-Insensitive Primer, 3M Unitek, Monrovia, Calif) and a self-etching primer (Transbond Plus Self-etching Primer, 3M Unitek, Monrovia, Calif) to dry and saliva contaminated enamel surfaces before and after primer application. Bovine mandibular incisors (60) were divided into 6 groups. Each primer was tested under 3 different enamel surface conditions: (1) dry, (2) saliva application before priming and (3) priming, saliva application and repriming. Stainless steel brackets were bonded in each test group with composite resin (Transbond XT, 3M Unitek, Monrovia, Calif). After bonding, all samples were stored at 37ºC in a humidity environment and tested for shear bond strength. The hydrophilic primer presented comparable results in a dry and in a saliva contaminated surface, while the self-etching primer had higher bond strength in moisture contaminated enamel. Comparing both primers under dry conditions, the hydrophilic primer provided a stronger bond than self-etching primer. However, no difference was found between these primers under saliva contaminated conditions. The results of this study indicate that, in optimal moisture control conditions or in clinical situations were saliva contamination is inevitable, Transbond self-etching primer or Transbond Moisture-Insensitive Primer could be applied and acceptable bond strength would be achieved.

32 31 INTRODUCTION Direct bonding of orthodontic brackets with composite resin has resulted in improvements in the orthodontic treatment such as greater comfort for the patient, decreased gingival irritation, easier plaque control, improved esthetics and reduced chairside time. 1-3 Success in direct bonding, however, requires knowledge of orthodontic and restorative dentistry principles. 4 Traditional composite resin demands an isolated and dried field to obtain clinically acceptable bond strength. 5 However, it is difficult to maintain the enamel completely free from saliva or blood contamination, especially during bracket bonding of lingual or impacted tooth surfaces 6, 7 as well as second molars and partially irrupted teeth. 8 Moisture contamination with saliva, gingival fluid or water reduces bond strength significantly and is considered the most common reason for bond failure. 9,10 Salivary contamination of the enamel results in an adherent coating that is not removed by washing the tooth s surface, compromising the bond between enamel and resin, and resulting in adhesive fractures. 10 Therefore, to ensure adequate bonding, the adherent organic coating had to be removed by re-etching the enamel surface. 11,10 The enamel etching pattern found in teeth not contaminated, however, can not be reestablished in surfaces that are re-etched since along with the organic pellicle, an additional enamel layer is lost. 12 Following the acid etching procedures, there is the rinsing and drying stages that are difficult for both patient and operators since the etched enamel must remain free from contamination. 13 Assessments have indicated that conventional hydrophobic primers do not offer adequate bond strength under conditions of moisture contamination. 14

33 32 The development of bonding agents, such as self-etching primers, which eliminates the rinsing stage, could not only save time and improve patient comfort but also provide moisture control. 13 Self-etching primers are formed by a phosphoric acid and a methacrylate group combined into a molecule, methacrylated phosphoric acid ester, that etches and primes at the same time. 9,15 Rather than being rinsed away, the phosphate group dissolves the calcium from the hydroxiapatite and forms a complex that is incorporated into the network when the primer is polymerized, neutralizing the acid groups and stopping the etching process. 15 Self-etching primers, originally introduced in restorative dentistry to bond composite resin restorations to dentin and enamel, have recently been applied to bracket bonding in orthodontics. 9 According to the manufacturer, the Transbond Plus Self-etching Primer (Transbond SEP, 3M Unitek) works in both moist and dry environment. On the other hand, new hydrophilic enamel primers for use in orthodontic treatment have been formulated with ethanol or acetone to displace moisture from the enamel during bonding procedures, resulting in successful bonding to contaminated dental surface. 5,11 The Moisture- Insensitive Primer (MIP, 3M Unitek) is a hydrophilic primer developed to tolerate small quantities of moisture. After rinsing and removing the etchant, drying of the tooth surface before priming is not required. Furthermore, according to the manufacturer s instructions, if contamination occurs after the application of the primer, re-etching, rinsing and drying the enamel surface would not be necessary if another coat of MIP was applied. Bonding agents formulated for moist and dry environments, eliminating even some stages during the bonding procedure, could not only save time but also assure a satisfactory bonding in orthodontics. Choosing between these adhesives in situations where there is an evident risk of salivary contamination, however, is difficult.

34 33 The purpose of this study was to evaluate the shear bond strength of orthodontic brackets bonded with a hydrophilic and a self-etching primer to dry and saliva contaminated enamel surfaces. MATERIAL AND METHODS Teeth Sixty bovine incisors were collected and stored in a solution of 0.1% Thymol at room temperature. Before bonding procedures all teeth had their crown embedded in acrylic resin. Each crown was polished on A180-grade sandpaper without water coolant followed by 220, 400 and 600-grade sandpaper with water coolant until the enamel buccal surfaces were exposed and partially flattened. All specimens were positioned in the center of a PVC tube with plaster inside using a device 16 to align the buccal surface of the teeth parallel to the shearing force. The facial surface of each incisor was cleaned with a mixture of pumice and water with a rubber-polishing cup on a low-speed handpiece for 10 seconds. The enamel surface was rinsed with water for 20 seconds and dried with an absorbent paper. Brackets used Edgewise stainless steel metal brackets for upper central incisors with a.022-in slot were used (Morelli, São Paulo, SP). The area of the bracket base surface is mm 2. protocols: Bonding procedures The teeth were randomly divided into 6 groups and bonded according to one of the 6

35 34 Group 1 Uncontaminated Transbond SEP. The primer, containing both acid and primer, was rubbed for 5 seconds onto the enamel surface. A gentle air burst was delivered to the tooth for 2 seconds. Group 2 Contamination before Transbond SEP application. The enamel surface was contaminated with human saliva for 15 seconds with a microbrush. The saliva was collected from the same donor at the moment of the application, at least an hour after the last meal. The primer was applied to the contaminated surface for 5 seconds and lightly air-dried for 2 seconds. Group 3 Transbond SEP reapplied after contamination. The primer was rubbed for 5 seconds and lightly air-dried for 2 seconds. The enamel surface was contaminated with saliva for 15 seconds. Transbond SEP was reapplied for 5 seconds and air-thinned for 2 seconds. Group 4 Uncontaminated Moisture-Insensitive Primer (MIP). The enamel surface was etched with 37% phosphoric acid (Alfa Etch Gel, DFL, Rio de Janeiro, RJ) for 30 seconds, washed for 20 seconds and dried with an absorbent paper. MIP was applied with a microbrush and lightly air-dried for 2 seconds. Group 5 Contamination before MIP. After acid etching, washing and drying, the enamel surface was contaminated with human saliva for 15 seconds with the use of a microbrush. The primer was applied and lightly air-dried for 2 seconds. Group 6 MIP reapplied after contamination. The enamel was acid etched, washed and dried. The primer was applied and lightly air-dried for 2 seconds. The enamel surface was contaminated with saliva for 15 seconds. MIP was reapplied and air-dried for 2 seconds. A light-cured resin (Transbond XT) was used for bracket bonding. The resin was applied to the bracket base following tooth conditioning and priming with either the Transbond SEP or the two-stage etch and prime MIP as described in groups 1-6 above. Excess bonding resin was removed with a sharp scalpel and each side of the bracket was light cured for 10 seconds using a

36 35 LED curing unit (Ultraled XP, Dabi Atlante, Ribeirão Preto, SP). The brackets were placed on the tooth s surface with a bonding tweezer and with the use of the device, the slot was positioned perpendicular to the PVC tube s base (Fig 1). Each tooth was identified with a marker to which group it belonged. After bonding, all teeth were stored at 37ºC ± 1ºC in a humidity environment for 4 days. Bond strength testing The device was attached to the testing machine (Emic DL2000, São José dos Pinhais, PR). Each tooth was positioned in the device with its buccal surface parallel to the direction of the shear force. An occlusogengival load was applied to the bracket with a crosshead speed of 1mm/min, as according to previous studies. 8,9 The shear force (N) required to debond each bracket was recorded and converted to bond strength in megapascals according to the following equation: Bond Force ( N) strength ( MPa) = Area ( m ) where Area (m 2 ) is the surface area of the bracket base. Statistical analysis Descriptive statistics including the mean, standard deviation and median values were calculated for each of the groups tested. The Student t test was used to determine whether significant differences were present in the bond strength between the groups. Significance for the statistic test was predetermined at a probability value of.05 or less (p 0.05).

37 36 RESULTS The descriptive statistics for the shear bond strength of the six groups evaluated are presented in Table 1. The results of the Student t test comparing the shear bond strength of the groups are presented in Tables 2 through 4. Results in the Transbond SEP groups (Table 2) indicate that group 1 (uncontaminated) presented a lower shear bond strength which was statistically different from groups 2 (p = 0.010) and 3 (p = 0.001), contaminated before and contaminated after primer respectively. No statistical difference was found comparing Transbond SEP group 2 with Transbond SEP group 3. Results in the MIP groups (Table 3) demonstrate no statistical difference between groups 4, 5 and 6. However, the shear bond strength mean value of MIP group 5 (mean, ± 7.25 MPa) was lower than the mean value for group 4 (mean, ± MPa) and group 6 (mean, ± 4.85). When comparing the Transbond SEP groups and the MIP groups (Table 4) used under the same enamel conditions, a significant difference (p = 0.001) was found between Transbond SEP group 1 (mean, ± MPa) and MIP group 4 (mean, ± MPa), both groups with enamel uncontaminated. However, no significant difference was found between Transbond SEP group 2 and MIP group 5 (both groups with enamel contamination before primer) or between Transbond SEP group 3 and MIP group 6 (both groups with enamel contamination after primer). DISCUSSION In this study, 2 types of primers (Transbond SEP and Transbond MIP) were evaluated under different enamel conditions.

38 37 The results indicate that in dry enamel condition, Transbond SEP (group 1) presents shear bond strength significantly lower than in saliva contaminated bonding conditions (groups 2 and 3). According to the manufacture s instructions, after prophying and washing the tooth s surface, excess water should be removed, but the surface should not be dried. This could explain the results in the present study. Previous researches evaluating Transbond SEP under dry and contaminated enamel have shown conflicting results. According to a report, no difference was found for SEP in both dry and moisture-contaminated fields, 9 whereas in other, bond strength of the self-etching primer was significantly reduced in the presence of saliva. 14 There was no significant difference between the Transbond SEP groups 2 and 3; therefore, saliva contamination before or after priming with SEP did not significantly affect the bond achieved, if SEP was reapplied after saliva contamination. In agreement to other study, when SEP is used, if moisture contamination is detected, reapplying SEP will provide acceptable bond strength. 9 In the present study, no statistical difference was found between the MIP groups in dry or contaminated conditions, even though saliva contamination before primer application (group 5) resulted in lower mean shear bond strength. The same results were also observed in a previous research, which concluded that saliva contamination before MIP application showed more frequent bond failures at the enamel/adhesive interface, suggesting that complete penetration of the primer was prevented, whereas the group with saliva contamination after primer application showed more frequent failures at the adhesive/bracket interface. 1 The presence of organic and inorganic substrates from saliva and viscosity of saliva might occlude partially the microscopic roughness produced by etching, inhibiting tag formation. 6

39 38 In contrast to the findings in the current research, other authors observed that Transbond MIP had significantly lower shear bond strength in moisture-contaminated surfaces than in dry enamel. 9 When tested under the same enamel condition, Transbond SEP (group 1) in a dry field had a shear bond strength significantly lower than the MIP group (group 4). The clinical implication of this finding could be that in optimal bonding conditions, Transbond MIP would provide a stronger bond than SEP. 9 Decreased bond strength for SEP, in conditions of ideal moisture control, compared with that of the conventional two-stage bonding system has been recorded. 9,17 Even though the self-etching primer and the phosphoric acid may produce a similar etching pattern, lower bond strengths were observed for the self-etching systems. Since no correlation was found between the strength of the bonds and the aggressiveness of the selfetching primers, apparently the strengths of the resin-enamel bonds were influenced by the strength of the resin and not by the etching capacity of these primers. 18 When using an acidic primer, the resin tags are thin and less uniform, favorable to a weaker bond and less adhesive remain on the tooth at the time of debonding, while the resin tags with phosphoric acid are thick and uniform. 19 Other studies, however, have reported similar bond strengths to these same hydrophilic and self-etching primers in uncontaminated enamel surface. 8,14 In the present results, no significant difference was found between Transbond SEP and MIP groups (2 and 5) with saliva contamination before primer application, even though lower mean shear bond strength was found for the MIP group. Higher strength value for Transbond SEP in the same enamel condition was also obtained in other study. 8

40 39 Reapplication of Transbond SEP and MIP (groups 3 and 6) to enamel surfaces with initial primer application contaminated by saliva resulted in high shear bond strengths and no significant difference between these groups. It does not seem that re-etching is required as long as additional primer is applied after moisture contamination. The results in the present study indicate that the enamel s conditions, dry or with moisture, have more influence in the performance of Transbond SEP than it does for Transbond MIP. The latter, in contrast, has comparable results in a moisture-free or moisture contaminated enviroment. Although differences were found between the groups in this study, the shear bond strength obtained for all groups were well above the guidelines established for clinically acceptable bond strength. Bond strengths of 6 to 8 MPa are considered adequate for most clinical orthodontic needs. 2,5,8 According to the results of this study, in optimal moisture control conditions or in clinical situations were saliva contamination is inevitable Transbond SEP or MIP could be applied and satisfactory bonding results would be achieved. CONCLUSION The hydrophilic primer, Transbond MIP, presented comparable results in a dry and in saliva contaminated surface, while the self-etching primer, Transbond SEP, had higher shear bond strength in moisture contaminated enamel. The comparison of both primers under dry conditions indicates that the hydrophilic primer provides a stronger bond than the self-etching primer. However, no difference was found between these primers under saliva contaminated conditions. The present study indicates that in optimal bonding conditions or in a clinical

41 40 situation where the risk of saliva contamination is evident, either Transbond SEP or Transbond MIP could be the primer of choice.

42 41 TABLE 1 - Descriptive statistics Groups Mean (MPa) SD Median (MPa) 1. Transbond SEP (uncontaminated) Transbond SEP (contaminated before primer) Transbond SEP (contaminated after primer) MIP (uncontaminated) MIP (contaminated before primer) MIP (contaminated after primer) SD = standard deviation MPa = Megapascal

43 42 TABLE 2 - Student t test comparing the shear bond strength between the Transbond SEP groups. Groups Comparison of Groups t value p value 1. Transbond SEP (uncontaminated) 1 vs 2 1 vs (s) (s) 2. Transbond SEP (contaminated before primer) 2 vs Transbond SEP (contaminated after primer) vs = versus (s) = statistically different groups p 0.05

44 43 TABLE 3 - Student t test comparing the shear bond strength between the MIP groups. Groups Comparison of Groups t value p value 4. MIP (uncontaminated) 4 vs 5 4 vs MIP (contaminated before primer) 5 vs MIP (contaminated after primer) vs = versus (s) = statistically diferent groups p 0.05

45 44 TABLE 4 - Student t test comparing the shear bond strength between the Transbond SEP and MIP groups used in same enamel conditions. Groups Enamel conditions t value p value 1. Transbond SEP vs 4. MIP Uncontaminated (s) 2. Transbond SEP vs 5. MIP Contamination before primer Transbond SEP vs 6. MIP Contamination after primer vs = versus (s) = statistically diferent groups p 0.05

46 Fig 1 - Bracket bonding 45

47 46 REFERENCES 1. SCHANEVELDT S, FOLEY TF. Bond strength comparison of moisture-insensitive primers. Am J Orthod Dentofac Orthop. 2002;122: GRANDHI RK, COMBE EC, SPEIDEL TM. Shear bond strength of stainless steel orthodontic brackets with a moisture-insensitive primer. Am J Orthod Dentofac Orthop. 2001;119: SOUZA CS, FRANCISCONI PAS, ARAÚJO PA. Bond strength of five cements for orthodontic use. Rev FOB. 1999; 7: ZACHRISSON BU: Bonding in Orthodontics. In: GRABER TM, VANARSDALL RL. Orthodontics: Current Principles and Techniques. ed 3. Rio de Janeiro, 2002, Guanabara Koogan. 5. WEBSTER MJ, NANDA RS, DUNCANSON MG, KHAJOTIA SS, SINHA PK. The effect of saliva on shear bond strengths of hydrophilic bonding systems. Am J Orthod Dentofac Orthop. 2001;119: ITOH T, FUKUSHIMA T, INOUE Y, ARITA S, MIYAZAKI K. Effect of water, saliva and blood contamination on bonding of metal brackets with a 4-META/MMB/TBB resin to etched enamel. Am J Dent. 1999;12:

48 47 7. MORAES M, SINHORETI MAC, CONSANI S, MIKAMI JR. Comparative study among adhesion procedures of the orthodontic buttom for traction of retained teeth. Rev Dent Press Ortodon Ortop Facial. 1998;3: CACCIAFESTA V, SFONDRINI MF, ANGELIS M, SCRIBANTE A, KLERSY C. Effect of water and saliva contamination on shear bond strength of brackets bonded with conventional, hydrophilic, and self-etching primers. Am J Orthod Dentofac Orthop. 2003;123: ZEPPIERI IL, CHUNG C, MANTE FK. Effect of saliva on shear bond strength of an orthodontic adhesive used with moisture-insensitive and self-etching primers. Am J Orthod Dentofac Orthop. 2003;124: SILVERSTONE LM, HICKS MJ, FEATHERSTONE MJ. Oral fluid contamination of etched enamel surfaces: an SEM study. J Am Dent Assoc. 1985;110: FRITZ UB, FINGER WJ, STEAN H. Salivary contamination during bonding procedures with a one-bottle adhesive system. Quint Int. 1998; 29: MENEZES LM. The influence of both salivary contamination on etched enamel and the reetching of this contaminated surface concerning shear bond strength. [master s thesis]. Rio de Janeiro City, Rio de Janeiro: Federal University of Rio de Janeiro; IRELAND AJ, KNIGHT H, SHERRIFF M. An in vivo investigation into bond failure rates with a new self-etching primer system. Am J Orthod Dentofac Orthop. 2003;124:

49 RAJAGOPAL R; PADMANABHAN, S.; GNANAMANI, J. A comparison of shear bond strength and debonding characteristics of conventional, moisture-insensitive, and self-etching primers in vitro. Angle Orthod. 2004; 74: BUYUKYILMAZ T, USUMEZ S, KARAMAN AI. Effect of self-etching primers on bond strength are they reliable? Angle Orthod. 2003;73: TORTAMANO A, VIGORITO JW, NAUFF F, GARONE GM, SANTOS RSC. Evaluation of the tensile strength of cementing agents for orthodontic brackets. Rev APCD. 2002; 56: ALJUBOURI YD, MILLETT DT, GILMOUR WH. Laboratory evaluation of a self-etching primer for orthodontic bonding. Eur J Orthod 2003; 25: PASHLEY DH, TAY FR. Agressiveness of contemporary self-etching adhesives. Part II: etching effects on unground enamel. Dent Mater, v. 17, n.5, p , BISHARA SE, GORDAN VV, VONWALD L, OLSON ME. Effect of an acidic primer on shear bond strength of orthodontic brackets. Am J Orthod Dentofac Orthop, 1998; 114:

50 ARTIGO 2 Orthodontic bonding in dry and saliva contaminated enamel: is a self-etching primer or a moisture-insensitive primer necessary? Cristiane Becher Rosa, DDS ª Roberto Amarante Costa Pinto, DDS, MSc b Fernando Antonio Lima Habib, DDS, MSc c ª Postgraduate student, Department of Orthodontics and Dentofacial Orthopedics, Dentistry School, Federal University of Bahia, Salvador, Bahia, Brazil. b Professor, Department of Orthodontics and Dentofacial Orthopedics, Dentistry School, Federal University of Bahia, Salvador, Bahia, Brazil. c Professor, Department of Orthodontics and Dentofacial Orthopedics, Dentistry School, Federal University of Bahia, Salvador, Bahia, Brazil. Correspondence: Dr. Cristiane Becher Rosa, Departamento de Ortodontia, Faculdade de Odontologia da Universidade Federal da Bahia, Av. Araújo Pinho, 62, Canela, CEP Salvador BA, Brazil. Telephone: (55-71) Fax: (55-71) becherrosa@gmail.com

51 50 Abstract The purpose of this study was to compare the shear bond strength of orthodontic bonding without primer application to bonding with the use of a hydrophilic primer (Transbond Moisture- Insensitive Primer, 3M Unitek, Monrovia, Calif) and a self-etching primer (Transbond Plus Selfetching Primer, 3M Unitek, Monrovia, Calif) in dry and saliva contaminated enamel surfaces. Bovine mandibular incisors (60) were divided into 6 groups. The experimental groups consisted of: (1) uncontaminated control (no primer), (2) control with saliva contamination (no primer) (3) uncontaminated self-etching primer, (4) saliva contamination before self-etching primer, (5) uncontaminated hydrophilic primer and (6) saliva contamination before hydrophilic primer. Stainless steel brackets were bonded in each test group with composite resin (Transbond XT, 3M Unitek, Monrovia, Calif). After bonding, all samples were stored at 37ºC in a humidity environment and tested for shear bond strength. Significance for the statistic test was predetermined at a probability value of.05 or less (p 0.05). Under dry uncontaminated enamel conditions comparable results were found between the control (1) and the self-etching primer (3), while the hydrophilic primer presented higher bond strength. Under saliva contamination, a significant difference was found between the control (2) and the self-etching primer, however, there was no difference between the self-etching primer and the hydrophobic primer group. Therefore, in moisture control situations the use of a primer in order to achieve acceptable bond strength is not required. This study indicates that in clinical situations where there is a risk of saliva contamination either primer could be used.

52 51 All orthodontic bonding systems involve at least two interfaces, the enamel/resin interface and the bracket/resin interface. If prime is used, then another interface is introduced, the primer/resin interface. 1 The use of a primer increases bond strength reducing undesirable bracket bonding failures during the orthodontic treatment. As a result, a higher rate of bond failure at the composite resin/enamel interface could occur along with enamel fractures. 2,3 Less residual adhesive remaining on the tooth surface might be an advantage to the clinician because it would require less time to clean the teeth after debonding. 4 However, at the end of treatment, a sound unblemished enamel surface must be maintained after debonding orthodontic brackets. 2 On the other hand, there are clinical situations where moisture control is difficult such as bracket bonding to lingual tooth surfaces or during surgical exposure of impacted teeth. 5,6 Failure of orthodontic bonded attachments and brackets is mostly attributed to contamination of the enamel. Materials have been developed to overcome the moisture and contaminants present in the oral enviroment. 7 The use of hydrophilic primers could therefore be used to enhance bond strength that otherwise would be compromised by the enamel contamination. New hydrophilic enamel primers for use in orthodontic treatment have been formulated with ethanol and/or acetone as ingredients to displace moisture from the enamel surface and produce clinically acceptable bond strength in either dry or wet fields. 7 Transbond Moisture- Insensitive Primer (Transbond MIP) is, according to the manufacturer, a hydrophilic adhesive that can be used on dry or water/saliva contaminated enamel surfaces. Recently, self-etch primers containing both the enamel etchant and primer have also been used in bonding of orthodontic brackets. 2 According to the manufacturer Transbond Plus Self- Etching Primer (Transbond SEP) can be applied to dry and wet enamel surfaces. The advantages

53 52 of using these acidic primers should include fewer steps in the bonding process translated into fewer procedural errors, time saving, 8-10 improved patient comfort and easier moisture control. 11 Previous studies evaluating Transbond SEP and Transbond MIP, under dry and contaminated enamel, have shown conflicting results to which is more effective in both environments. The comparison of these primers to a control group without the presence of a primer has yet not been assessed, since in these previous studies a hydrophobic primer is used as a control group. 9,12-14 The objective of this study is to evaluate if the presence of a primer is indeed necessary to achieve acceptable bond strength for orthodontic bonding under different enamel treatments, dry and saliva contaminated, and if so, which adhesive would be more satisfactory. Material and methods Sixty bovine incisors were collected and stored in a solution of 0.1% Thymol at room temperature. Before bonding procedures all teeth had their crown embedded in acrylic resin. Each crown was polished on A180-grade sandpaper without water coolant followed by 220, 400 and 600-grade sandpaper with water coolant until the enamel buccal surfaces were exposed and partially flattened. All specimens were positioned in the center of a PVC tube with plaster inside using a device 15 to align the buccal surface of the teeth parallel to the shearing force. The facial surface of each incisor was cleaned with a mixture of pumice and water with a rubber-polishing cup on a low-speed handpiece for 10 seconds. The enamel surface was rinsed with water for 20 seconds and dried with an absorbent paper. The teeth were randomly divided into 6 groups and bonded according to one of the 6 protocols:

54 53 Group 1 Control (without saliva contamination). The enamel was etched with 37% phosphoric acid (Alfa Etch Gel, DFL, Rio de Janeiro, RJ) for 30 seconds, washed for 20 seconds and dried with an absorbent paper. No primer was used. Group 2 Control (with saliva contamination). The enamel was etched with 37% phosphoric acid for 30 seconds, washed for 20 seconds and dried with an absorbent paper. The dental surface was contaminated with human saliva for 15 seconds with a microbrush. The saliva was collected from the same donor at the moment of the application, at least an hour after the last meal. No primer was used. Group 3 Uncontaminated Transbond SEP. The primer, containing both acid and primer, was rubbed for 5 seconds onto the enamel surface. A gentle airburst was delivered to the tooth for 2 seconds. Group 4 Contamination before Transbond SEP. The enamel surface was contaminated with human saliva for 15 seconds. The primer was applied to the contaminated surface for 5 seconds and lightly air-dried for 2 seconds. Group 5 Uncontaminated Moisture-Insensitive Primer (MIP). The enamel surface was etched with 37% phosphoric acid for 30 seconds, washed for 20 seconds and dried with an absorbent paper. MIP was applied with a microbrush and lightly air-dried for 2 seconds. Group 6 Contamination before MIP. After acid etching, washing and drying, the enamel surface was contaminated with human saliva for 15 seconds with the use of a microbrush. The primer was applied and lightly air-dried for 2 seconds. A light-cured resin (Transbond XT) was used for bracket bonding. Edgewise stainless steel metal brackets for upper central incisors with a.022-in slot (Morelli, São Paulo, SP), with a base area of mm 2, were used. The resin was applied to the bracket base following tooth conditioning or tooth etching and priming as described in groups 1-6 above. Excess bonding resin

55 54 was removed with a sharp scalpel and each side of the bracket was light cured for 10 seconds using a LED curing unit (Ultraled XP, Dabi Atlante, Ribeirão Preto, SP). The brackets were placed on the tooth s surface with a bonding tweezer and with the use of a device the bracket s slot was positioned perpendicular to the PVC ring s base (Fig 1). Each tooth was identified with a marker to which group it belonged. After bonding, all teeth were stored at 37ºC ± 1ºC in a humidity environment for 4 days. The device was attached to the testing machine (Emic DL2000, São José dos Pinhais, PR). Each tooth was positioned in the device with its buccal surface parallel to the direction of the shear force. An occlusogengival load was applied to the bracket with a crosshead speed of 1mm/min, as according to previous studies. 9,13 The shear force required to debond each bracket was recorded and converted to Megapascals as a ratio of Newtons to surface area of the bracket base. Bond Force ( N) strength ( MPa) = Area ( m ) Statistical analysis Descriptive statistics including the mean, standard deviation and median values were calculated for each of the groups tested. The Student t test was used to determine whether significant differences were present in the bond strength between the groups. Significance for the statistic test was predetermined at a probability value of.05 or less (p 0.05).

56 55 Results The descriptive statistics for the shear bond strength of the six groups evaluated are presented in Table 1. The results of the Student t test comparing the shear bond strength of the groups are presented in Tables 2 and 3. When comparing the uncontaminated groups (Table 2), results of the Student t test indicates no significant difference between the control group 1 and the Transbond SEP group 3, although the latter showed a higher bond strength mean value (mean, ± MPa). A statistical difference was observed, however, between control group 1 and MIP group 5 (p = 0.000) and between Transbond SEP group 3 and MIP group 5 (p = 0.001). The shear bond strength of the groups with saliva contamination (Table 3) presented a statistical difference between control group 2 and Transbond SEP group 4 (p = 0.000). No statistical difference was observed between control group 2 and MIP group 6 (p = 0.062). Comparisons between Transbond SEP group 4 and MIP group 6 were also not significantly different (p= 0,352). Discussion The present study demonstrated that in dry enamel surfaces no difference was found between the control group, in which no primer was applied, and Transbond SEP group. Both groups had bond strengths that are adequate for clinical orthodontic needs, indicating that under moisture control conditions, the application of a primer is not necessary. This could simplify clinical procedures, reduce chairside time and be more cost-effective. Previous studies with other bonding agents also indicate no significant difference in the bond strength values whether or not the agent was used before bonding. 16,17 On the other hand, another research demonstrates that

57 56 with the use of a primer there is a bigger tag formation, which results in higher bond strength values that may imply in a greater risk of cohesive fracture of the enamel during debonding procedures. 3 The application of MIP in a dry enamel surface in the present study resulted, however, in significantly higher bond strengths that were well above the requirement for the guidelines established for clinically acceptable bond strength. Although in vitro studies do not necessarily have the same results as those obtained in the oral environment, the shear bond strength necessary for a satisfactory clinical performance is inferior to the bonding capacity of the primers. 3,16 Bond strengths of 6 to 8 MPa are considered adequate for most clinical orthodontic needs. 3,7,13 Another factor that should not be forgotten is that orthodontic attachments and brackets will be removed in 2 or 3 years at the end of treatment and that the adhesive/enamel union has another perspective in comparison to restorative dentistry where the bonding should preferably last a lifetime. Maximum shear bond strength is not essential in orthodontic bonding. 3 It should, however, be sufficient to withstand masticatory and orthodontic forces 3,7 but also avoid enamel trauma during bracket debonding at the end of treatment. 2,3 If the strength of the micromechanical retention is strong, a fracture upon the removal of the bracket will lie partly in the resin and partly in the enamel structure. 18 However, bonding in enamel surface contaminated with saliva without the use of a primer resulted in shear bond strength lower than the minimal required for an acceptable bonding. A significant difference was found between the control and Transbond SEP groups, both under saliva contamination. The high t value (t =110,3) obtained, indicates that among all groups that presented a statistical difference in this research, the most significant difference was found when comparing these two groups.

58 57 No statistical difference, however, was observed between the control group contaminated with saliva and MIP under the same enamel condition, although the mean values of these groups were so discrepant. This could be explained by the high standard deviation of these groups, which has great influence in the results of the Student t test. The use of either primers, Transbond SEP or MIP, seem adequate for situations where saliva contamination is possible. It has been reported, however, that the depth of the etched enamel surface created by phosphoric acid may contribute to the incidence of enamel fracture. 19 The self-etching primers do not penetrate or dissolve the enamel surface to the same depth as conventional adhesive systems that use phosphoric acid, 19,20 minimizing the amount of enamel loss during etching Other studies, evaluating resin tag penetration and assessment of the amount of resin material adhering to the enamel surface among the groups studied in this research, could inform if there would be a statistical difference in relation to enamel fracture with or without the use of these primers. Conclusion 1. Under dry uncontaminated enamel surfaces there is no need for the use of a primer in order to achieve acceptable bond strength. No significant difference was found between the self-etching primer and the control group, while the hydrophobic primer group presented higher shear bond strength values. 2. Under saliva contaminated enamel conditions the absence of a primer resulted in insufficient bond strength.

59 58 3. The self-etching primer, Transbond SEP, and the hydrophilic primer, Transbond MIP, presented high shear bond strength in dry and saliva contaminated enamel conditions. Thus, either could be the primer of choice in clinical situations in which the risk of saliva contamination is evident.

60 59 TABLE 1 - Descriptive statistics Groups Mean (MPa) SD Median (MPa) 1. Control (without saliva contamination) Control (with saliva contamination) Transbond SEP (uncontaminated) Transbond SEP (contaminated before primer) MIP (uncontaminated) MIP (contaminated before primer) SD = standard deviation MPa = Megapascal

61 60 TABLE 2 - Student t test comparing the shear bond strength between Control, Transbond SEP and MIP groups on enamel without saliva contamination. Groups Uncontaminated Comparison of Groups t value p value 1. Control 1 vs 3 1 vs (s) 3. Transbond SEP 3 vs (s) 5. MIP vs = versus (s) = Statistically different groups p 0.05

62 61 TABLE 3 - Student t test comparing the shear bond strength between Control, Transbond SEP and MIP groups on enamel with saliva contamination. Groups Contaminated Comparison of Groups t value p value 2. Control 2 vs 4 2 vs (s) Transbond SEP 4 vs MIP vs = versus (s) = Statistically different groups p 0.05

63 Fig 1. Bracket bonding 62

I NÉDITO. Cristiane Becher Rosa*, Roberto Amarante Costa Pinto**, Fernando Antonio Lima Habib**

I NÉDITO. Cristiane Becher Rosa*, Roberto Amarante Costa Pinto**, Fernando Antonio Lima Habib** A RTIGO I NÉDITO Colagem ortodôntica em esmalte com presença ou ausência de contaminação salivar: é necessário o uso de adesivo auto-condicionante ou de adesivo hidrofílico? Cristiane Becher Rosa*, Roberto

Leia mais

UNIÃO DE MATERIAIS ADESIVOS À CERÂMICA E AO POLÍMERO

UNIÃO DE MATERIAIS ADESIVOS À CERÂMICA E AO POLÍMERO PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO GRANDE DO SUL FACULDADE DE ODONTOLOGIA PROGRAMA DE PÓS-GRADUAÇÃO EM ODONTOLOGIA-DOUTORADO ÁREA DE CONCENTRAÇÃO EM DENTÍSTICA RESTAURADORA UNIÃO DE MATERIAIS ADESIVOS

Leia mais

SÉRGIO MILTON MARTINS DE OLIVEIRA PENIDO

SÉRGIO MILTON MARTINS DE OLIVEIRA PENIDO UNIVERSIDADE ESTADUAL PAULISTA CAMPUS DE ARARAQUARA FACULDADE DE ODONTOLOGIA SÉRGIO MILTON MARTINS DE OLIVEIRA PENIDO Penido, Sérgio Milton Martins de Oliveira Estudo comparativo in vivo e in vitro da

Leia mais

Manual de Colagem Ortodôntica Direta

Manual de Colagem Ortodôntica Direta Manual de Colagem Ortodôntica Direta Até o início da década de 70 os tratamentos ortodônticos eram realizados soldando os bráquetes às bandas em todos os dentes. Introdução Após o advento da técnica do

Leia mais

EFEITO DE DIFERENTES MÉTODOS DE REMOÇÃO DE RESINA REMANESCENTE NA RECOLAGEM DE ACESSÓRIOS ORTODÔNTICOS

EFEITO DE DIFERENTES MÉTODOS DE REMOÇÃO DE RESINA REMANESCENTE NA RECOLAGEM DE ACESSÓRIOS ORTODÔNTICOS EFEITO DE DIFERENTES MÉTODOS DE REMOÇÃO DE RESINA REMANESCENTE NA RECOLAGEM DE ACESSÓRIOS ORTODÔNTICOS Cássio Alexandre Zeri de Oliveira (PIBITI/CNPq-Unopar), e-mail: cassio_55_@hotmail.com. Paula Vanessa

Leia mais

MÓDULO DE ELASTICIDADE E GRAU DE CONVERSÃO DE MONÔMEROS DE SISTEMAS ADESIVOS AUTOCONDICIONANTES E PRIMER E ADESIVO COMBINADOS

MÓDULO DE ELASTICIDADE E GRAU DE CONVERSÃO DE MONÔMEROS DE SISTEMAS ADESIVOS AUTOCONDICIONANTES E PRIMER E ADESIVO COMBINADOS BIANCA MORO CORRÊA MÓDULO DE ELASTICIDADE E GRAU DE CONVERSÃO DE MONÔMEROS DE SISTEMAS ADESIVOS AUTOCONDICIONANTES E PRIMER E ADESIVO COMBINADOS Dissertação apresentada à Faculdade de Odontologia da Pontifícia

Leia mais

Resistência ao cisalhamento de bráquetes metálicos colados com compósitos em diferentes condições de esmalte utilizando potencializador de adesão

Resistência ao cisalhamento de bráquetes metálicos colados com compósitos em diferentes condições de esmalte utilizando potencializador de adesão Esta é um versão gerada unicamente para visualização dentro do SGP. A versão a ser impressa utilizará outros padrões de formatação. This is a version generated only for visualization inside of SGP. The

Leia mais

IVANA AGNOLETTO SOUZA AVALIAÇÃO DA RESISTÊNCIA DE UNIÃO DAS INTERFACES DE CIMENTAÇÃO DE ONLAYS EM RESINA COMPOSTA CAD/CAM

IVANA AGNOLETTO SOUZA AVALIAÇÃO DA RESISTÊNCIA DE UNIÃO DAS INTERFACES DE CIMENTAÇÃO DE ONLAYS EM RESINA COMPOSTA CAD/CAM IVANA AGNOLETTO SOUZA AVALIAÇÃO DA RESISTÊNCIA DE UNIÃO DAS INTERFACES DE CIMENTAÇÃO DE ONLAYS EM RESINA COMPOSTA CAD/CAM Dissertação apresentada como requisito para obtenção do grau de Mestre em Odontologia

Leia mais

A pasta de limpeza universal Ivoclean limpa efetivamente as superfícies de adesão de restaurações protéticas após a prova intraoral

A pasta de limpeza universal Ivoclean limpa efetivamente as superfícies de adesão de restaurações protéticas após a prova intraoral Used Products DENTES - Facetas - Dissilicato de Lítio - Variolink N LC - Tetric N-Bond Variolink N LC O cimento resinoso micropartiliculado, fotopolimerizável Proxyt livre de flúor Pasta profilática sem

Leia mais

Avaliação da força de tração em braquetes colados pela técnica indireta com diferentes sistemas de adesão

Avaliação da força de tração em braquetes colados pela técnica indireta com diferentes sistemas de adesão A r t i g o In é d i t o Avaliação da força de tração em braquetes colados pela técnica indireta com diferentes sistemas de adesão André Tortamano*, Fábio Nauff**, Sandra Regina Frazatto Naccarato***,

Leia mais

A pasta de limpeza universal Ivoclean limpa efetivamente as superfícies de adesão de restaurações protéticas após a prova intraoral

A pasta de limpeza universal Ivoclean limpa efetivamente as superfícies de adesão de restaurações protéticas após a prova intraoral Used Products DENTES - Pontes - Dissilicato de Lítio - Preparo Não -Retentivo - Variolink N - ExciTE F DSC Variolink N Cimento resinoso dual e fotopolimerizável, adequado para cimentação adesiva de restaurações

Leia mais

A pasta de limpeza universal Ivoclean limpa efetivamente as superfícies de adesão de restaurações protéticas após a prova intraoral

A pasta de limpeza universal Ivoclean limpa efetivamente as superfícies de adesão de restaurações protéticas após a prova intraoral Used Products DENTES - Facetas - Compósitos - Variolink N LC - Syntac Variolink N LC O cimento resinoso micropartiliculado, fotopolimerizável Proxyt livre de flúor Pasta profilática sem flúor OptraStick

Leia mais

Avaliação da resistência ao cisalhamento do compósito Right-On em diferentes condições de esmalte

Avaliação da resistência ao cisalhamento do compósito Right-On em diferentes condições de esmalte A RTIGO I NÉDITO Avaliação da resistência ao cisalhamento do compósito Right-On em diferentes condições de esmalte Matheus Melo Pithon*, Luiz Antônio Alves Bernardes**, Antônio Carlos de Oliveira Ruellas***,

Leia mais

AVALIAÇÃO DA RESISTÊNCIA AO CISALHAMENTO DO COMPÓSITO EAGLE BOND

AVALIAÇÃO DA RESISTÊNCIA AO CISALHAMENTO DO COMPÓSITO EAGLE BOND Artigo Original AVALIAÇÃO DA RESISTÊNCIA AO CISALHAMENTO DO COMPÓSITO EAGLE BOND EVALUATION OF THE SHEAR BOND STRENGTH OF THE EAGLE BOND COMPOSITE Resumo Matheus Melo Pithon 1 Márlio Vinícius de Oliveira

Leia mais

Avaliação da resistência ao cisalhamento de dois compósitos colados em superfície condicionada com primer autocondicionante

Avaliação da resistência ao cisalhamento de dois compósitos colados em superfície condicionada com primer autocondicionante A r t i g o I n é d i t o Avaliação da resistência ao cisalhamento de dois compósitos colados em superfície condicionada com primer autocondicionante Matheus Melo Pithon*, Rogério Lacerda dos Santos**,

Leia mais

A pasta de limpeza universal Ivoclean limpa efetivamente as superfícies de adesão de restaurações protéticas após a prova intraoral

A pasta de limpeza universal Ivoclean limpa efetivamente as superfícies de adesão de restaurações protéticas após a prova intraoral Used Products DENTES - Coroas - Cerâmica Vítrea - Multilink N Multilink N Cimento resinoso universal autopolimerizável Proxyt livre de flúor Pasta profilática sem flúor OptraStick Acessório que possui

Leia mais

fluxograma Variolink N

fluxograma Variolink N fluxograma Variolink N DENTES - Coroas - Dissilicato de Lítio - Preparo Não -Retentivo - Variolink N - ExciTE F DSC 1 O temporário é removido O material provisório é removido. Se necessário, o restante

Leia mais

A pasta de limpeza universal Ivoclean limpa efetivamente as superfícies de adesão de restaurações protéticas após a prova intraoral

A pasta de limpeza universal Ivoclean limpa efetivamente as superfícies de adesão de restaurações protéticas após a prova intraoral Used Products DENTES - Coroas - Dissilicato de Lítio - Preparo Retentivo - Subgengival - Multilink Speed Multilink Speed Cimento resinoso autoadesivo, autopolimerizável, com opção fotopolimerizável Proxyt

Leia mais

Comparação de Três Sistemas Adesivos Dentários Quanto à Resistência ao Cisalhamento da Colagem em Prémolares

Comparação de Três Sistemas Adesivos Dentários Quanto à Resistência ao Cisalhamento da Colagem em Prémolares TRABALHO DE PESQUISA Comparação de Três Sistemas Adesivos Dentários Quanto à Resistência ao Cisalhamento da Colagem em Prémolares A Comparison of the Shear Bond Strength of Three Dental Adhesive Systems

Leia mais

ESTUDO COMPARATIVO DA RESISTÊNCIA AO CISALHAMENTO DE BRÁQUETES METÁLICOS COLADOS COM CIMENTOS DE IONÔMERO DE VIDRO REFORÇADOS COM RESINA

ESTUDO COMPARATIVO DA RESISTÊNCIA AO CISALHAMENTO DE BRÁQUETES METÁLICOS COLADOS COM CIMENTOS DE IONÔMERO DE VIDRO REFORÇADOS COM RESINA Artigo Original ESTUDO COMPARATIVO DA RESISTÊNCIA AO CISALHAMENTO DE BRÁQUETES METÁLICOS COLADOS COM CIMENTOS DE IONÔMERO DE VIDRO REFORÇADOS COM RESINA A COMPARATIVE STUDY ABOUT SHEAR BOND STRENGTH OF

Leia mais

Duziene Denardini Pereira ANÁLISE DA ADAPTAÇÃO MARGINAL DE FACETAS LAMINADAS CONFECCIONADAS PELA TECNOLOGIA CAD/CAM: ESTUDO IN VITRO

Duziene Denardini Pereira ANÁLISE DA ADAPTAÇÃO MARGINAL DE FACETAS LAMINADAS CONFECCIONADAS PELA TECNOLOGIA CAD/CAM: ESTUDO IN VITRO Duziene Denardini Pereira ANÁLISE DA ADAPTAÇÃO MARGINAL DE FACETAS LAMINADAS CONFECCIONADAS PELA TECNOLOGIA CAD/CAM: ESTUDO IN VITRO Dissertação de mestrado apresentada ao Curso de Odontologia, Área de

Leia mais

fluxograma Variolink N

fluxograma Variolink N fluxograma Variolink N DENTES - Pontes - Dissilicato de Lítio - Preparo Não -Retentivo - Variolink N - Syntac 1 O temporário é removido O material provisório é removido. Se necessário, o restante do cimento

Leia mais

Oconceito de prevenção às doenças periodontais

Oconceito de prevenção às doenças periodontais ISSN 00347272 ARTIGO ORIGINAL Avaliação da resistência ao cisalhamento de novo cimento de ionômero de vidro em diferentes condições de esmalte Evaluation of the shear bond strength of the new glass ionomer

Leia mais

Bifix QM. Sistema de cimentação resinosa de

Bifix QM. Sistema de cimentação resinosa de Bifix QM Bifix QM Sistema de cimentação resinosa de polimerização Dual Bifix QM Sistema de cimentação resinosa de polimerização dual Uma cimentação duradoura de metais e ligas não-metálicas, cerâmicas

Leia mais

PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO GRANDE DO SUL FACULDADE DE ODONTOLOGIA PROGRAMA DE PÓS-GRADUAÇÃO EM ODONTOLOGIA

PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO GRANDE DO SUL FACULDADE DE ODONTOLOGIA PROGRAMA DE PÓS-GRADUAÇÃO EM ODONTOLOGIA PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO GRANDE DO SUL FACULDADE DE ODONTOLOGIA PROGRAMA DE PÓS-GRADUAÇÃO EM ODONTOLOGIA MESTRADO EM DENTÍSTICA RESTAURADORA AVALIAÇÃO DA RESISTÊNCIA DE UNIÃO DE ADESIVOS

Leia mais

INFLUÊNCIA DA CONTAMINAÇÃO COM SALIVA ARTIFICIAL NA RESISTÊNCIA AO CISALHAMENTO DE SISTEMAS ADESIVOS AUTOCONDICIONANTES EM ESMALTE BOVINO

INFLUÊNCIA DA CONTAMINAÇÃO COM SALIVA ARTIFICIAL NA RESISTÊNCIA AO CISALHAMENTO DE SISTEMAS ADESIVOS AUTOCONDICIONANTES EM ESMALTE BOVINO SERGIO RICARDO CAMPOS MAIA INFLUÊNCIA DA CONTAMINAÇÃO COM SALIVA ARTIFICIAL NA RESISTÊNCIA AO CISALHAMENTO DE SISTEMAS ADESIVOS AUTOCONDICIONANTES EM ESMALTE BOVINO Dissertação apresentada para obtenção

Leia mais

Avaliação In Vitro de Diferentes Tempos de Fotoativação na Colagem de Brackets com Compósito Utilizando Primer Autocondicionante 1

Avaliação In Vitro de Diferentes Tempos de Fotoativação na Colagem de Brackets com Compósito Utilizando Primer Autocondicionante 1 TRABALHO DE PESQUISA Avaliação In Vitro de Diferentes Tempos de Fotoativação na Colagem de Brackets com Compósito Utilizando Primer Autocondicionante 1 In Vitro Evaluation of Different Cure Times in Bracket

Leia mais

O efeito do jateamento do esmalte na força de adesão na colagem de braquetes

O efeito do jateamento do esmalte na força de adesão na colagem de braquetes A RTIGO I NÉDITO O efeito do jateamento do esmalte na força de adesão na colagem de braquetes Carla D Agostini Derech*, Juliana da Silva Pereira**, Margareth Maria Gomes de Souza*** Resumo Objetivo: o

Leia mais

Estudo comparativo in vitro da resistência ao cisalhamento da colagem e do índice de remanescente adesivo entre os compósitos Concise e Fill Magic

Estudo comparativo in vitro da resistência ao cisalhamento da colagem e do índice de remanescente adesivo entre os compósitos Concise e Fill Magic A r t i g o I n é d i t o Estudo comparativo in vitro da resistência ao cisalhamento da colagem e do índice de remanescente adesivo entre os compósitos Concise e Fill Magic Matheus Melo Pithon*, Rogério

Leia mais

Resistência ao cisalhamento da colagem dos compósitos Concise e Transbond XT com e sem agente de união

Resistência ao cisalhamento da colagem dos compósitos Concise e Transbond XT com e sem agente de união A r t i g o I n é d i t o Resistência ao cisalhamento da colagem dos compósitos Concise e Transbond XT com e sem agente de união Alexandre Maêda Neves*, Fábio Lourenço Romano**, Américo Bortolazzo Correr***

Leia mais

análise de variância a um critério (ANOVA) e teste de Tuckey. Para comparar os

análise de variância a um critério (ANOVA) e teste de Tuckey. Para comparar os 40 Figura 14- Máquina Universal de Ensaios Mecânicos (maquina eletromecânica da marca EMIC Modelo DL 3000) Figura 15- Espécime em posição de tração Os dados obtidos foram analisados estatisticamente ao

Leia mais

RelyX Ultimate Cimento Resinoso Adesivo

RelyX Ultimate Cimento Resinoso Adesivo RelyX Ultimate Cimento Resinoso Adesivo Cimentação definitiva de: Restaurações indiretas em cerâmica condicionável, cerâmica não condicionável, resina e metal. Inlays / Onlays Coroas Próteses Fixas Próteses

Leia mais

Influência de variáveis metodológicas na resistência de união ao cisalhamento

Influência de variáveis metodológicas na resistência de união ao cisalhamento A R T I G O I N É D I T O 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 Influência de variáveis metodológicas na resistência de

Leia mais

Avaliação em mev de esmalte condicionado previamente contaminado com soro fisiológico

Avaliação em mev de esmalte condicionado previamente contaminado com soro fisiológico Avaliação em mev de esmalte condicionado previamente contaminado com soro fisiológico Mev evaluation of conditional enamel previously contaminated with physiological serum Leandro Azambuja REICHERT Rafael

Leia mais

Resistência ao cisalhamento. de bráquetes ortodônticos metálicos em dentes submetidos. ao clareamento dentário

Resistência ao cisalhamento. de bráquetes ortodônticos metálicos em dentes submetidos. ao clareamento dentário Resistência ao cisalhamento de submetidos ao clareamento dentário Orthodontic metal brackets resistance in whitened teeth subjected to shear strength Jézlia Chris da Silva Galdino 1 Bruna Laís Lins Gonçalves

Leia mais

Óxido de zinco (ZnO 2 )

Óxido de zinco (ZnO 2 ) Material Híbrido Óxido de zinco (ZnO 2 ) Ácido fosfórico H 3 (PO 4 ) Ácido poliacrílico C 3 H 4 O 2 Eugenol Fosfato de zinco Óxido de zinco/eugenol Policarboxilato de zinco Cimento de silicato Ácido fosfórico

Leia mais

UNIVERSIDADE FEDERAL DA BAHIA FACULDADE DE ODONTOLOGIA MESTRADO EM ODONTOLOGIA LETÍCIA OLIVEIRA SARAIVA

UNIVERSIDADE FEDERAL DA BAHIA FACULDADE DE ODONTOLOGIA MESTRADO EM ODONTOLOGIA LETÍCIA OLIVEIRA SARAIVA UNIVERSIDADE FEDERAL DA BAHIA FACULDADE DE ODONTOLOGIA MESTRADO EM ODONTOLOGIA LETÍCIA OLIVEIRA SARAIVA INFLUÊNCIA DA UMIDADE E TEMPERATURA INTRABUCAIS NA RESISTÊNCIA DE UNIÃO DE SISTEMAS ADESIVOS CONVENCIONAIS

Leia mais

Cimentos para Fixação (Prof. Braga)

Cimentos para Fixação (Prof. Braga) DEPARTAMENTO DE BIOMATERIAIS E BIOLOGIA ORAL Disciplina ODB 401 Materiais para uso indireto Roteiro de estudos Data: 18/04/2017 Cimentos para Fixação (Prof. Braga) 1 Introdução Conceito de cimento (Houaiss):

Leia mais

REAPLICAÇÃO DE CALCÁRIO NO SISTEMA PLANTIO DIRETO CONSOLIDADO. ANTONIO SERGIO DO AMARAL Eng. Agr. (UDESC)

REAPLICAÇÃO DE CALCÁRIO NO SISTEMA PLANTIO DIRETO CONSOLIDADO. ANTONIO SERGIO DO AMARAL Eng. Agr. (UDESC) REAPLICAÇÃO DE CALCÁRIO NO SISTEMA PLANTIO DIRETO CONSOLIDADO ANTONIO SERGIO DO AMARAL Eng. Agr. (UDESC) REAPLICAÇÃO DE CALCÁRIO EM SISTEMA PLANTIO DIRETO CONSOLIDADO" Autor: Antonio Sergio do Amaral

Leia mais

Influência de variáveis metodológicas na resistência de união ao cisalhamento

Influência de variáveis metodológicas na resistência de união ao cisalhamento A r t i g o I n é d i t o Influência de variáveis metodológicas na resistência de união ao cisalhamento Marcel Marchiori Farret*, Tatiana Siqueira Gonçalves**, Eduardo Martinelli S. de Lima***, Luciane

Leia mais

Resistência à remoção de braquetes ortodônticos sob ação de diferentes cargas contínuas

Resistência à remoção de braquetes ortodônticos sob ação de diferentes cargas contínuas A RTIGO I NÉDITO Resistência à remoção de braquetes ortodônticos sob ação de diferentes cargas contínuas Carla Giannini*, Paulo Afonso Silveira Francisconi** Resumo Objetivo: testar se existe alteração

Leia mais

ALL-BOND 3. Instructions for Use. Bisco. Universal Dental Adhesive System. Dual- Cured

ALL-BOND 3. Instructions for Use. Bisco. Universal Dental Adhesive System. Dual- Cured Bisco ALL-BOND 3 Dual- Cured Universal Dental Adhesive System 0459 Instructions for Use PT IN-159R5 Rev. 9/17 US Patents 7,748,980 & 8,026,297 BISCO, Inc. 1100 W. Irving Park Rd. Schaumburg, IL 60193 U.S.A.

Leia mais

BIS-SILANE. Bisco Instructions for Use. 2-Part Porcelain Primer

BIS-SILANE. Bisco Instructions for Use. 2-Part Porcelain Primer Bisco 0459 BIS-SILANE 2-Part Porcelain Primer Instructions for Use PT IN-151R9 Rev. 2/19 BISCO, Inc. 1100 W. Irving Park Rd. Schaumburg, IL 60193 U.S.A. 1-847-534-6000 1-800-247-3368 BIS-SILANE * Porcelain

Leia mais

Estudo in vitro da resistência ao cisalhamento da colagem direta de tubos ortodônticos em molares

Estudo in vitro da resistência ao cisalhamento da colagem direta de tubos ortodônticos em molares A r t i g o I n é d i t o Estudo in vitro da resistência ao cisalhamento da colagem direta de tubos ortodônticos em molares Célia Regina Maio Pinzan Vercelino*, Arnaldo Pinzan**, Júlio de Araújo Gurgel***,

Leia mais

Resumo. Daniela MINATTI* Celso YAMASHITA** Luciano MADEIRA***

Resumo. Daniela MINATTI* Celso YAMASHITA** Luciano MADEIRA*** ISSN 1806-7727 Avaliação de diferentes tratamentos mecânicos de superfícies na resistência à tração de reparos em resina composta direta Evaluation of different mechanical surface treatments in tensile

Leia mais

ANEXO VI MODELO DE PROPOSTA (PAPEL TIMBRADO DA EMPRESA)

ANEXO VI MODELO DE PROPOSTA (PAPEL TIMBRADO DA EMPRESA) ANEXO VI MODELO DE PROPOSTA (PAPEL TIMBRADO DA EMPRESA) Ao, Excelentíssimo Senhor, Prefeito Municipal de Três de Maio Apresentamos abaixo nossa proposta para fornecimento de material odontológico para

Leia mais

RelyX U200 Cimento Resinoso Autoadesivo

RelyX U200 Cimento Resinoso Autoadesivo RelyX U200 Cimento Resinoso Autoadesivo Cimentação definitiva de: Restaurações indiretas em cerâmica condicionável, cerâmica não condicionável, resina e metal. Inlays / Onlays Coroas Próteses Fixas Próteses

Leia mais

Influência do tempo pós-fixação na resistência ao cisalhamento de bráquetes colados com diferentes materiais

Influência do tempo pós-fixação na resistência ao cisalhamento de bráquetes colados com diferentes materiais Pesqui Odontol Bras v. 16, n. 1, p. 43-49, jan./mar. Materiais Dentários Influência do tempo pós-fixação na resistência ao cisalhamento de bráquetes colados com diferentes materiais Influence of post-fixation

Leia mais

3M Single Bond Universal Adesivo

3M Single Bond Universal Adesivo 3M Single Bond Universal Adesivo Guia Técnico MENU 2 Guia Técnico A 3M desenvolveu este guia técnico interativo, para que você alcance os melhores resultados usando o 3M Single Bond Universal nos seus

Leia mais

Trabalho de Conclusão de Curso

Trabalho de Conclusão de Curso Trabalho de Conclusão de Curso AVALIAÇÃO DA RESISTÊNCIA DE UNIÃO DE BRAQUETES ORTODÔNTICOS COLADOS COM DIFERENTES TÉCNICAS Diogo Alencar Cé Universidade Federal de Santa Catarina Curso de Graduação em

Leia mais

Dr. Marco. Fechamento de Diastema com Resina Composta Direta como Método Eficaz Estético e Funcional Após Finalização Ortodôntica

Dr. Marco. Fechamento de Diastema com Resina Composta Direta como Método Eficaz Estético e Funcional Após Finalização Ortodôntica INTRODUÇÃO Atualmente a procura pela estética e boa aparência do sorriso proporciona ao mercado desenvolvimento de novas técnicas e novos materiais para suprir as necessidades dos pacientes, ou seja, o

Leia mais

Influência do agente clareador peróxido de carbamida a 10% na resistência mecânica da colagem de braquetes ortodônticos

Influência do agente clareador peróxido de carbamida a 10% na resistência mecânica da colagem de braquetes ortodônticos A r t i g o I n é d i t o Influência do agente clareador peróxido de carbamida a 10% na resistência mecânica da colagem de braquetes ortodônticos Edgard Norões R. da Matta*, José de Albuquerque Calasans

Leia mais

Resistência adesiva após colagem e recolagem de bráquetes: um estudo in vitro

Resistência adesiva após colagem e recolagem de bráquetes: um estudo in vitro doi: 10.7213/archivesoforalresearch.09.002.AO08 ISSN 2236-8035 Archives of Oral Research, v. 9, n. 2, p. 201-206, May/Aug. 2013 Licensed under a Creative Commons License [T] Resistência adesiva após colagem

Leia mais

EROSÃO EM ENTRESSULCOS E EM SULCOS SOB DIFERENTES TIPOS DE PREPARO DO SOLO E MANEJO DE RESÍDUOS CULTURAIS

EROSÃO EM ENTRESSULCOS E EM SULCOS SOB DIFERENTES TIPOS DE PREPARO DO SOLO E MANEJO DE RESÍDUOS CULTURAIS EROSÃO EM ENTRESSULCOS E EM SULCOS SOB DIFERENTES TIPOS DE PREPARO DO SOLO E MANEJO DE RESÍDUOS CULTURAIS VLADIMIR SILVA DE LIMA Engenheiro Agrônomo - UFRGS EROSÃO EM ENTRESSULCOS E EM SULCOS SOB DIFERENTES

Leia mais

LUCIANA KEIKO SHINTOME*, MARCELO FAVA* *, SILVIO ISSÁO MYAKI* * UNITERMOS ABSTRACT

LUCIANA KEIKO SHINTOME*, MARCELO FAVA* *, SILVIO ISSÁO MYAKI* * UNITERMOS ABSTRACT Condicionamento ácido em diferentes regiões do esmalte de molares decíduos LUCIANA KEIKO SHINTOME*, MARCELO FAVA* *, SILVIO ISSÁO MYAKI* * RESUMO O objetivo deste estudo in vitro foi de avaliar ao microscópio

Leia mais

Poucos. possibilidades. passos, RelyX Ultimate Cimento Resinoso Adesivo LANÇAMENTO. múltiplas

Poucos. possibilidades. passos, RelyX Ultimate Cimento Resinoso Adesivo LANÇAMENTO. múltiplas LANÇAMENTO RelyX Ultimate Cimento Resinoso Adesivo O RelyX TM Ultimate é o mais novo e inovador cimento resinoso adesivo dual da 3M ESPE, desenvolvido especialmente para atender uma demanda de alta estética

Leia mais

O CIMENTO QUE VOCÊ JÁ CONHECE AGORA LHE OFERECE AINDA MAIS VANTAGENS!

O CIMENTO QUE VOCÊ JÁ CONHECE AGORA LHE OFERECE AINDA MAIS VANTAGENS! O CIMENTO QUE VOCÊ JÁ CONHECE AGORA LHE OFERECE AINDA MAIS VANTAGENS! RASTREABILIDADE Ao remover o aparelho fixo ou recimentar uma peça, Orthocem UV Trace permite identificar remanescentes de cimento no

Leia mais

Estudo comparativo da resistência ao cisalhamento utilizando diferentes bráquetes metálicos colados em incisivos bovinos

Estudo comparativo da resistência ao cisalhamento utilizando diferentes bráquetes metálicos colados em incisivos bovinos Artigo Original Original article Estudo comparativo da resistência ao cisalhamento utilizando diferentes bráquetes metálicos colados em incisivos bovinos Comparative study of shear strength using different

Leia mais

Ade são. Coesão do A. de União. Ade são Esm X. Coesão do Esmalte. Coesão do. dos bráquetes: X Brq

Ade são. Coesão do A. de União. Ade são Esm X. Coesão do Esmalte. Coesão do. dos bráquetes: X Brq Colagem Colagem X Bandagem de Bráquetes Dificuldade de higienização Complexidade e morosidade de execução clínica Comprometimento da estética Simplicidade Diminuição do tempo de cadeira Melhor estética

Leia mais

Contaminação salivar e o recondicionamento ácido de esmalte dental humano

Contaminação salivar e o recondicionamento ácido de esmalte dental humano ORIGINAL ORIGINAL Contaminação salivar e o recondicionamento ácido de esmalte dental humano Salivary contamination and reconditioning of human dental enamel Meire Coelho FERREIRA 1 Mirian de Waele Souchois

Leia mais

ICT/ UNESP: TCC RESUMO

ICT/ UNESP: TCC RESUMO Guia Prático de Normalização ICT/ UNESP: TCC NBR 14724 / NBR 6028 Definição Apresentação concisa dos pontos relevantes de um texto, fornecendo uma visão rápida e clara do conteúdo e das conclusões do trabalho.

Leia mais

Colagem de braquetes em esmalte condicionado com Transbond Plus Self Etching Primer

Colagem de braquetes em esmalte condicionado com Transbond Plus Self Etching Primer Dica Clínica Colagem de braquetes em esmalte condicionado com Transbond Plus Self Etching Primer Fábio Lourenço Romano*, Américo Bortolazzo Correr**, Maria Beatriz B. A. Magnani***, Darcy Flávio Nouer****,

Leia mais

maior opacidade Maior opacidade resultando em melhor estética final

maior opacidade Maior opacidade resultando em melhor estética final Opus Bulk Fill Flow é uma resina composta fluida indicada para a técnica bulk filling, como base e forramento de restaurações adesivas diretas. Devido à sua baixa tensão de contração e grande profundidade

Leia mais

Comparação in vitro da resistência ao cisalhamento na interface PAD de resina/esmalte dentário

Comparação in vitro da resistência ao cisalhamento na interface PAD de resina/esmalte dentário Comparação in vitro da resistência ao cisalhamento na interface PAD de resina/esmalte dentário Shear strength in vitro comparison in the PAD interface of dental resin/enamel João Sarmento Pereira Neto

Leia mais

Scotch-Weld MR DP-810 / DP810NS Adesivo Acrílico de Baixo Odor

Scotch-Weld MR DP-810 / DP810NS Adesivo Acrílico de Baixo Odor MR / DP810NS Adesivo Acrílico de Baixo Odor Dados Técnicos Agosto/2008 Em substituição a versão de Agosto de 1998 Descrição do Produto Os Adesivos Acrílicos de Baixo Odor 3M MR MR e NS possuem dois componentes

Leia mais

PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO GRANDE DO SUL FACULDADE DE ODONTOLOGIA

PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO GRANDE DO SUL FACULDADE DE ODONTOLOGIA 1 PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO GRANDE DO SUL FACULDADE DE ODONTOLOGIA PROGRAMA DE PÓS-GRADUAÇÃO EM ODONTOLOGIA CONCENTRAÇÃO EM DENTÍSTICA RESTAURADORA JONAS PEREIRA ANDRADE Efeito da espessura

Leia mais

Avaliação da resistência adesiva da recolagem de bráquetes ortodônticos após diferentes protocolos de remoção de resina residual

Avaliação da resistência adesiva da recolagem de bráquetes ortodônticos após diferentes protocolos de remoção de resina residual Avaliação da resistência adesiva da recolagem de bráquetes ortodônticos após diferentes protocolos de remoção de resina residual Evaluation of bond strength of orthodontic brackets after rebonding of different

Leia mais

UNIVERSIDADE FEDERAL DA BAHIA FACULDADE DE ODONTOLOGIA CENTRO DE ORTODONTIA E ORTOPEDIA FACIAL PROF. JOSÉ ÉDIMO SOARES MARTINS

UNIVERSIDADE FEDERAL DA BAHIA FACULDADE DE ODONTOLOGIA CENTRO DE ORTODONTIA E ORTOPEDIA FACIAL PROF. JOSÉ ÉDIMO SOARES MARTINS UNIVERSIDADE FEDERAL DA BAHIA FACULDADE DE ODONTOLOGIA CENTRO DE ORTODONTIA E ORTOPEDIA FACIAL PROF. JOSÉ ÉDIMO SOARES MARTINS AVALIAÇÃO DA RESISTÊNCIA AO CISALHAMENTO DE BRAQUETES, COLADOS COM SISTEMAS

Leia mais

0459 ALL-BOND UNIVERSAL

0459 ALL-BOND UNIVERSAL Bisco 0459 ALL-BOND UNIVERSAL Light-Cured Dental Adhesive Instructions for Use PT IN-193R8 Rev. 8/17 BISCO, Inc. 1100 W. Irving Park Road Schaumburg, IL 60193 U.S.A. 1-847-534-6000 1-800-247-3368 ALL-BOND

Leia mais

ALL BOND 2 GUIA TÉCNICO DPO IMP. EXP. E COM. DE PRODUTOS ODONTOLÓGICOS LTDA

ALL BOND 2 GUIA TÉCNICO DPO IMP. EXP. E COM. DE PRODUTOS ODONTOLÓGICOS LTDA ALL BOND 2 GUIA TÉCNICO DPO IMP. EXP. E COM. DE PRODUTOS ODONTOLÓGICOS LTDA Rua Itapicuru, 495 Perdizes CEP 05006-000 São Paulo SP Fone (11) 3670-1070 www.oraltech.com.br ALL BOND 2 DICAS ÚTEIS O ALL BOND

Leia mais

Used Products. Multilink N. OptraDam. N-Etch. Monobond N. MultiCore. DENTES - Pino Intrarradicular - Metal - Multilink N

Used Products. Multilink N. OptraDam. N-Etch. Monobond N. MultiCore. DENTES - Pino Intrarradicular - Metal - Multilink N Used Products DENTES - Pino Intrarradicular - Metal - Multilink N Multilink N Cimento resinoso universal autopolimerizável OptraDam OptraDam Plus é um dique de borracha moldado anatomicamente para o isolamento

Leia mais

RESISTÊNCIA AO CISALHAMENTO DE DOIS SISTEMAS ADESIVOS DE FRASCO ÚNICO E UM COM PRIMER AUTOCONDICIONANTE

RESISTÊNCIA AO CISALHAMENTO DE DOIS SISTEMAS ADESIVOS DE FRASCO ÚNICO E UM COM PRIMER AUTOCONDICIONANTE Revista de Odontologia da Universidade Cidade de São Paulo 2006 set-dez; 18(3)233-7 RESISTÊNCIA AO CISALHAMENTO DE DOIS SISTEMAS ADESIVOS DE FRASCO ÚNICO E UM COM PRIMER AUTOCONDICIONANTE SHEAR BOND STRENGTH

Leia mais

Remodelação cosmética do sorriso com laminados cerâmicos devido a desgaste dentário patológico

Remodelação cosmética do sorriso com laminados cerâmicos devido a desgaste dentário patológico www.kulzer.com.br GLUMA 2Bond / Variotime Easy Putty e Variotime Light Flow Leonardo Fernandes da Cunha Gabriela Andrade Serpa Carla Castiglia Gonzaga Gisele Maria Correr Saúde bucal nas melhores mãos.

Leia mais

PROCEDIMENTO DE INSTALAÇÃO DE TUBOS DE PVC E CPVC

PROCEDIMENTO DE INSTALAÇÃO DE TUBOS DE PVC E CPVC PROCEDIMENTO DE INSTALAÇÃO DE TUBOS DE PVC E CPVC DEFINIÇÕES GERAIS... 2 CONSIDERAÇÕES GERAIS... 2 PROCEDIMENTO DE COLAGEM... 4 1. CORTAR O TUBO... 41 2. PREPARAÇÃO DA JUNTA... 4 3. TESTE DE DIMENSÃO...

Leia mais

UNIVERSIDADE FEDERAL DE JUIZ DE FORA PÓS-GRADUAÇÃO EM SAÚDE MESTRADO EM SAÚDE BRASILEIRA JOSÉ MAURÍCIO DA ROCHA

UNIVERSIDADE FEDERAL DE JUIZ DE FORA PÓS-GRADUAÇÃO EM SAÚDE MESTRADO EM SAÚDE BRASILEIRA JOSÉ MAURÍCIO DA ROCHA UNIVERSIDADE FEDERAL DE JUIZ DE FORA PÓS-GRADUAÇÃO EM SAÚDE MESTRADO EM SAÚDE BRASILEIRA JOSÉ MAURÍCIO DA ROCHA AVALIAÇÃO DAS CARGAS DE ADESÃO E DAS SUPERFÍCIES DO ESMALTE DENTÁRIO APÓS A REMOÇÃO DE BRÁQUETES

Leia mais

RESTAURAÇÃO DE MOLAR DECÍDUO COM RESINA COMPOSTA DE ÚNICO INCREMENTO RELATO DE UM CASO CLÍNICO

RESTAURAÇÃO DE MOLAR DECÍDUO COM RESINA COMPOSTA DE ÚNICO INCREMENTO RELATO DE UM CASO CLÍNICO 1 RESTAURAÇÃO DE MOLAR DECÍDUO COM RESINA COMPOSTA DE ÚNICO INCREMENTO RELATO DE UM CASO CLÍNICO Luana Azevedo Atayde Graduada em Odontologia pela Universidade Federal de Uberlândia (2014). Especialista

Leia mais

futurabond futurabond u adesivo universal de polimerização dual

futurabond futurabond u adesivo universal de polimerização dual ADESIVO UNIVERSAL DE POLIMERIZAÇÃO DUAL Pesquisa científica para o melhor adesivo A pesquisa científica na área dos adesivos teve imensos avanços nos últimos anos. A VOCO acompanhou esta trajetória com

Leia mais

UNIVERSIDADE FEDERAL DA BAHIA FACULDADE DE MEDICINA DA BAHIA PROGRAMA DE PÓS-GRADUAÇÃO EM CIÊNCIAS DA SAÚDE

UNIVERSIDADE FEDERAL DA BAHIA FACULDADE DE MEDICINA DA BAHIA PROGRAMA DE PÓS-GRADUAÇÃO EM CIÊNCIAS DA SAÚDE UNIVERSIDADE FEDERAL DA BAHIA FACULDADE DE MEDICINA DA BAHIA PROGRAMA DE PÓS-GRADUAÇÃO EM CIÊNCIAS DA SAÚDE CARVEL SUPRIEN CARACTERIZAÇÃO DAS MANIFESTAÇÕES CLÍNICAS, E RESPOSTA AO TRATAMENTO EM CRIANÇAS

Leia mais

Resistência de união de sistema adesivo com agentes antimicrobianos utilizado em Ortodontia

Resistência de união de sistema adesivo com agentes antimicrobianos utilizado em Ortodontia Artigo Original Resistência de união de sistema adesivo com agentes antimicrobianos utilizado em Ortodontia Shear bond strength of an adhesive system with antibacterial agents used in Orthodontics Resumo

Leia mais

Regras para uma boa colagem

Regras para uma boa colagem Regras para uma boa colagem Fabricio Gomes Gonçalves Informações gerais: 1) Propiciar condições para um íntimo contato entre o adesivo líquido e a superfície sólida ao longo da interface. usar superfície

Leia mais

Avaliação do efeito de tratamentos superficiais sobre a força de adesão de braquetes em provisórios de resina acrílica

Avaliação do efeito de tratamentos superficiais sobre a força de adesão de braquetes em provisórios de resina acrílica A r t i g o I n é d i t o Avaliação do efeito de tratamentos superficiais sobre a força de adesão de braquetes em provisórios de resina acrílica Deise Lima Cunha Masioli*, Marco Antonio de Oliveira Almeida**,

Leia mais

CALAGEM NA SUPERFÍCIE DO SOLO NO SISTEMA PLANTIO DIRETO EM CAMPO NATIVO. CIRO PETRERE Eng. Agr. (UEPG)

CALAGEM NA SUPERFÍCIE DO SOLO NO SISTEMA PLANTIO DIRETO EM CAMPO NATIVO. CIRO PETRERE Eng. Agr. (UEPG) CALAGEM NA SUPERFÍCIE DO SOLO NO SISTEMA PLANTIO DIRETO EM CAMPO NATIVO CIRO PETRERE Eng. Agr. (UEPG) CALAGEM NA SUPERFÍCIE DO SOLO NO SISTEMA PLANTIO DIRETO EM CAMPO NATIVO" Autor: Ciro Petrere Orientador:

Leia mais

VOLUME 19 FGM NEWS 61

VOLUME 19 FGM NEWS 61 VOLUME 19 FGM NEWS 61 REPENSE SEU CONCEITO DE POLIMERIZAÇÃO. Fotoquímica de polímeros é uma área de grande interesse na odontologia, haja visto que a fotopolimerização de materiais resinosos trouxe para

Leia mais

ESTUDO DO DESGASTE ABRASIVO DE AÇO CARBONITRETADO EM DIFERENTES RELAÇÕES AMÔNIA/PROPANO

ESTUDO DO DESGASTE ABRASIVO DE AÇO CARBONITRETADO EM DIFERENTES RELAÇÕES AMÔNIA/PROPANO UNIVERSIDADE FEDERAL DO PARANÁ PROGRAMA DE PÓS-GRADUAÇÃO EM ENGENHARIA E CIÊNCIAS DOS MATERIAIS PIPE ENGENHARIA E CIÊNCIAS DOS MATERIAIS - SETOR DE TECNOLOGIA SÉRGIO ZAGONEL ESTUDO DO DESGASTE ABRASIVO

Leia mais

CARLOS ALEXANDRE WOITCHUNAS CORRELAÇÃO ENTRE ABSORÇÃO DE ÁGUA E TRAÇÃO DIAMETRAL DE DOIS CIMENTOS RESINOSOS ORTODÔNTICOS

CARLOS ALEXANDRE WOITCHUNAS CORRELAÇÃO ENTRE ABSORÇÃO DE ÁGUA E TRAÇÃO DIAMETRAL DE DOIS CIMENTOS RESINOSOS ORTODÔNTICOS CARLOS ALEXANDRE WOITCHUNAS CORRELAÇÃO ENTRE ABSORÇÃO DE ÁGUA E TRAÇÃO DIAMETRAL DE DOIS CIMENTOS RESINOSOS ORTODÔNTICOS Porto Alegre 2011 CARLOS ALEXANDRE WOITCHUNAS CORRELAÇÃO ENTRE ABSORÇÃO DE ÁGUA

Leia mais

Estudo da Resistência Adesiva à Dentina Contaminada por Saliva

Estudo da Resistência Adesiva à Dentina Contaminada por Saliva TRABALHO DE PESQUISA Estudo da Resistência Adesiva à Dentina Contaminada por Saliva Study of the Shear Bond Strength to Dentin Contaminated with Saliva Alexandre Batista Lopes do NASCIMENTO* Hilcia Mezzalira

Leia mais

Caso Clínico White Post

Caso Clínico White Post Caso Clínico White Post Uso clínico de pino fibroresinoso O uso de pinos de fibra de vidro possibilita um meio de retenção para restaurações diretas ou indiretas. Este relato de caso clínico apresenta

Leia mais

Estudo da Resistência ao Cisalhamento na Colagem de Acessórios Ortodônticos com e sem Homogeneização da Resina Superbond 1

Estudo da Resistência ao Cisalhamento na Colagem de Acessórios Ortodônticos com e sem Homogeneização da Resina Superbond 1 TRABALHO DE PESQUISA Estudo da Resistência ao Cisalhamento na Colagem de Acessórios Ortodônticos com e sem Homogeneização da Resina Superbond 1 Study of Bond Strength to Shear Forces in Direct Bonding

Leia mais

BRUNO NEHME BARBO MODELOS DIGITAIS: COMPARAÇÃO DO ESCANEAMENTO EM DIFERENTES ANGULAÇÕES E DE 4 MÉTODOS DE SOBREPOSIÇÃO

BRUNO NEHME BARBO MODELOS DIGITAIS: COMPARAÇÃO DO ESCANEAMENTO EM DIFERENTES ANGULAÇÕES E DE 4 MÉTODOS DE SOBREPOSIÇÃO BRUNO NEHME BARBO MODELOS DIGITAIS: COMPARAÇÃO DO ESCANEAMENTO EM DIFERENTES ANGULAÇÕES E DE 4 MÉTODOS DE SOBREPOSIÇÃO Dissertação apresentada como parte dos requisitos obrigatórios para obtenção de grau

Leia mais

Avaliação da influência dos tipos de tratamento superficial da porcelana glazeada na colagem de braquetes ortodônticos

Avaliação da influência dos tipos de tratamento superficial da porcelana glazeada na colagem de braquetes ortodônticos A r t i g o In é d i t o Avaliação da influência dos tipos de tratamento superficial da porcelana glazeada na colagem de braquetes ortodônticos Camila Belo Falcão*, Adriano Marques Brito**, Fernando Jorge

Leia mais

Serviço de bandas pré-soldadas Morelli / Pre welding Morelli service

Serviço de bandas pré-soldadas Morelli / Pre welding Morelli service Bands bands Confiança e resistência, com maleabilidade. Trust and resistance, with malleability. As bandas ortodônticas Morelli são produzidas com aço de alta qualidade e tratadas termicamente para oferecer

Leia mais

AVALIAÇÃO DA RESISTÊNCIA ADESIVA E DA ATIVIDADE ANTIMICROBIANA DE DIFERENTES SISTEMAS DE COLAGEM DE BRÁQUETES ASSOCIADOS À CLOREXIDINA E AO FLÚOR

AVALIAÇÃO DA RESISTÊNCIA ADESIVA E DA ATIVIDADE ANTIMICROBIANA DE DIFERENTES SISTEMAS DE COLAGEM DE BRÁQUETES ASSOCIADOS À CLOREXIDINA E AO FLÚOR JORGE LUÍS DE OLIVEIRA RIBEIRO AVALIAÇÃO DA RESISTÊNCIA ADESIVA E DA ATIVIDADE ANTIMICROBIANA DE DIFERENTES SISTEMAS DE COLAGEM DE BRÁQUETES ASSOCIADOS À CLOREXIDINA E AO FLÚOR Dissertação apresentada

Leia mais

DEGUS TAÇÃO CORTESIA DO EDITOR

DEGUS TAÇÃO CORTESIA DO EDITOR DEGUS TAÇÃO CORTESIA DO EDITOR 01 02 PREPAROS DENTÁRIOS Os 5W s A previsão do tipo de preparo dentário a ser executado depende, basicamente, do relacionamento entre material restaurador selecionado, volume

Leia mais

Ponto de vista. Altamiro Flávio. Especialista em Prótese Dentária, UFU.

Ponto de vista. Altamiro Flávio. Especialista em Prótese Dentária, UFU. 54 Rev Dental Press Estét. 2013 jan-mar;10(1)54-7 Ponto de vista Na sua rotina clínica, você prefere realizar ou não bisel em restaurações diretas de resina composta em dentes anteriores? Altamiro Flávio

Leia mais

Prova de Seleção Mestrado LINGUA INGLESA 15/02/2016

Prova de Seleção Mestrado LINGUA INGLESA 15/02/2016 Prova de Seleção Mestrado LINGUA INGLESA 15/02/2016 Instruções aos candidatos: (1) Preencher somente o número de inscrição em todas as folhas. (2) Usar caneta preta ou azul. 1 2 3 4 5 6 7 8 9 10 11 12

Leia mais

Bráquetes Metálicos. Instrução de Uso. Indicação de uso:

Bráquetes Metálicos. Instrução de Uso. Indicação de uso: Bráquetes Metálicos Colado na superfície vestibular dos dentes, o Bráquete tem a finalidade de alojar o arco Intraoral, sendo que ambos determinam os esforços transmitidos aos elementos dentários corrigindo

Leia mais

MARIA PRISCILA DA SILVA PALMA FACETA DE CERÂMICA

MARIA PRISCILA DA SILVA PALMA FACETA DE CERÂMICA MARIA PRISCILA DA SILVA PALMA FACETA DE CERÂMICA CAMPINAS 2015 MARIA PRISCILA DA SILVA PALMA FACETA DE CERÂMICA Monografia apresentada ao curso de Odontologia da Faculdade São Leopoldo Mandic, como requisito

Leia mais

MANUAL DE EXECUÇÃO Pisos nora

MANUAL DE EXECUÇÃO Pisos nora MANUAL DE EXECUÇÃO Pisos nora I. PREPARAÇÃO DO CONTRA PISO; É de responsabilidade do cliente, garantir que o contra piso e o ambiente onde os revestimentos nora forem instalados possuam e mantenham ao

Leia mais

Adesivos. Adesivo dentina / esmalte monocomponente à base de Ormocer, fotopolimerizável. Admira Bond em embalagens de dose única (Single Dose)

Adesivos. Adesivo dentina / esmalte monocomponente à base de Ormocer, fotopolimerizável. Admira Bond em embalagens de dose única (Single Dose) Admira Bond Admira Bond Single Dose Adesivo dentina / esmalte monocomponente à base de Ormocer, fotopolimerizável Admira Bond em embalagens de dose única (Single Dose) Restauração directa com todos os

Leia mais

PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO GRANDE DO SUL FACULDADE DE ODONTOLOGIA PROGRAMA DE PÓS-GRADUAÇÃO EM ODONTOLOGIA

PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO GRANDE DO SUL FACULDADE DE ODONTOLOGIA PROGRAMA DE PÓS-GRADUAÇÃO EM ODONTOLOGIA PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO GRANDE DO SUL FACULDADE DE ODONTOLOGIA PROGRAMA DE PÓS-GRADUAÇÃO EM ODONTOLOGIA ÁREA DE CONCENTRAÇÃO DENTÍSTICA RESTAURADORA CAROLINA RITTER BROMBERG Influência

Leia mais