COMPARAÇÃO DA DEGRADAÇÃO DA FORÇA DE ELÁSTICOS ORTODONTICOS INTERMAXILARES DE LÁTEX E SINTÉTICOS QUANDO SUBMETIDOS À DISTENSÃO EM SALIVA ARTIFICIAL

Documentos relacionados
TÍTULO: ANÁLISE DA DEGRADAÇÃO DE FORÇA DE ANÉIS ELÁSTICOS ORTODÔNTICOS DE DIFERENTES INTENSIDADES

editorial / editorial artigos originais / Original Articles

Estudo da degradação da força gerada por elásticos ortodônticos sintéticos

Elásticos Ortodônticos: como Selecionálos e Utilizá-los de Maneira Eficaz

Bruno Oliveira Naime ESTUDO DA DEGRADAÇÃO DE ELÁSTICO PESADO EXTRA-ORAL

Percentual de degradação das forças liberadas por ligaduras elásticas

UNIVERSIDADE FEDERAL DO RIO GRANDE DO NORTE CENTRO DE CIÊNCIAS DA SAÚDE DEPARTAMENTO DE ODONTOLOGIA CURSO DE ODONTOLOGIA

SÉRGIO MILTON MARTINS DE OLIVEIRA PENIDO

Estudo in vitro da degradação da força de elásticos ortodônticos de látex sob condições dinâmicas*

UNIVERSIDADE FEDERAL DO RIO GRANDE DO NORTE CENTRO DE CIÊNCIAS DA SAÚDE DEPARTAMENTO DE ODONTOLOGIA CURSO DE ODONTOLOGIA

Influência do pré-estiramento nas forças geradas por elásticos ortodônticos em cadeia

Modelos digitais em Ortodontia

during the first 24 hours (p<0.001), but for the other time intervals, the force decrease was

VALÉRIO TOMÉ JÚNIOR AVALIAÇÃO DA DEGRADAÇÃO DA FORÇA DOS ELÁSTICOS ORTODÔNTICOS DE LÁTEX EM FUNÇÃO DO TEMPO DE ATIVAÇÃO

TÍTULO: AVALIAÇÃO DA DEFORMAÇÃO DE CADEIA ELÁSTICA SUBMETIDAS A DIFERENTES MEIOS DE DESCONTAMINAÇÃO

AVALIAÇÃO IN VITRO DA DEGRADAÇÃO DA

UNIVERSIDADE FEDERAL DO RIO GRANDE DO NORTE CENTRO DE CIÊNCIAS DA SAÚDE DEPARTAMENTO DE ODONTOLOGIA CURSO DE ODONTOLOGIA

Influência das soluções de glutaraldeído à 2% nas forças geradas pelos elásticos ortodônticos em cadeia

A Degradação da Força de Segmentos de Elásticos em Cadeia de Diferentes Tamanhos Estudo Comparativo In Vitro 1

ANÁLISE, IN VITRO, DA DEGRADAÇÃO DE FORÇAS DOS ANÉIS ELÁSTICOS ORTODÔNTICOS EM FUNÇÃO DA QUANTIDADE DE ATIVAÇÃO AURO SEYTI KIMURA

TADEU EVANDRO MENDES JUNIOR. Análise do decaimento de força dos elásticos ortodônticos intermaxilares

Avaliação das propriedades mecânicas dos elásticos e cadeias elastoméricas em ortodontia

Influência do Grau de Ativação na Deformação Plástica de Elásticos Ortodônticos em Cadeia

UNIVERSIDADE FEDERAL DO RIO GRANDE DO NORTE CENTRO DE CIÊNCIAS DA SAÚDE DEPARTAMENTO DE ODONTOLOGIA

Influência do pigmento na elasticidade em longo prazo de ligaduras elásticas

Avaliação das tensões liberadas por elásticos ortodônticos em cadeia: estudo in vitro

Estudo da alteração dimensional das diferentes cores e tipos de armazenamentos dos elásticos ortodônticos.

Palavras-chave: Elastômeros; Terapêutica; Ortodontia.

INSTRUÇÕES PARA AS APRESENTAÇÕES DE TRABALHOS CIENTÍFICOS

Elásticos para ligadura / Elastomeric ligatures

BRUNO NEHME BARBO MODELOS DIGITAIS: COMPARAÇÃO DO ESCANEAMENTO EM DIFERENTES ANGULAÇÕES E DE 4 MÉTODOS DE SOBREPOSIÇÃO

UNIVERSIDADE FEDERAL DA BAHIA FACULDADE DE MEDICINA DA BAHIA PROGRAMA DE PÓS-GRADUAÇÃO EM CIÊNCIAS DA SAÚDE

Universidade CEUMA - UNICEUMA Programa de Mestrado Acadêmico em Odontologia

Escola Politécnica/UFRJ

Resultados 68. Figura 23: Fotografia em microscopia óptica, fio Nitinol (3M Unitek), ampliação de 100x, antes (A) e após (B) a deflexão, lado α.

FABIANA BALLETE DE CARA ARAUJO ESTUDO COMPARATIVO DA DEGRADAÇÃO DE FORÇAS GERADAS POR ELÁSTICOS ORTODÔNTICOS SINTÉTICOS E MOLAS DE NÍQUEL-TITÂNIO

MESIALIZAÇÃO DE MOLARES COM O USO DE MINI-IMPLANTE

JANISE BIZARRO PEREIRA PORTO. AVALIAÇÃO IN VITRO DAS FORÇAS GERADAS POR CADEIAS ELÁSTICAS E MOLAS FECHADAS DE NiTi

Análise da discrepância de tamanho dentário em pacientes da Clínica de Ortodontia da FO/UERJ

UNIVERSIDADE FEDERAL DA FRONTEIRA SUL - UFFS CAMPUS ERECHIM LICENCIATURA EM PEDAGOGIA DANIÊ REGINA MIKOLAICZIK

Resumo. Alexandre Trindade Simões da MOTTA*, Samira RODRIGUES**, Cátia C. Abdo QUINTÃO***, Jonas CAPELLI JR.****

UNIVERSIDADE PAULISTA UNIP PROGRAMA DE MESTRADO EM ODONTOLOGIA AVALIAÇÃO DA ESTABILIDADE E COMPORTAMENTO

RETALHOS ÂNTERO-LATERAL DA COXA E RETO ABDOMINAL EM GRANDES RECONSTRUÇÕES TRIDIMENSIONAIS EM CABEÇA E PESCOÇO

Uso do método de Monte Carlo para validar a análise de incerteza da calibração do volume de um provador compacto realizada através do GUM

ANAIS WORKSHOP TEMPLE GRANDIN DE BEM-ESTAR ANIMAL 18 E 19 DE AGOSTO DE 2018 TEATRO GAMARO MÓOCA SÃO PAULO SP

Potencial da Telemedicina Dentária no diagnóstico oral infantil

Serviço de bandas pré-soldadas Morelli / Pre welding Morelli service

TRATAMENTO DA MORDIDA ABERTA ANTERIOR EM PACIENTE PADRÃO III RELATO DE CASO CLÍNICO

Dissertação de mestrado

Degradação da Força de Cadeias Elastoméricas com e sem Pré-Estiramento - Estudo Comparativo

Fios em varetas Morest standardcrni/ Wires sticks standard MorestCrNi. Fios em varetas Morealloy azulcocr / Wires sticks Morealloy bluecocr.

JANISE BIZARRO PEREIRA PORTO

UNIVERSIDADE CEUMA PRÓ-REITORIA DE PÓS-GRADUAÇÃO, PESQUISA E EXTENSÃO PROGRAMA DE PÓS-GRADUAÇÃO EM ODONTOLOGIA INTEGRADA IARA REGINA SERRA CAMPOS

Aplicação do Método de Elementos Finitos em Odontologia

UNIVERSIDADE PAULISTA - UNIP PROPRIEDADES FÍSICAS DE FIOS ORTODÔNTICOS DE AÇO APÓS UTILIZAÇÃO CLÍNICA CRISTINA YURI OKADA KOBAYASHI

Características oclusais de pacientes com. Classe II, divisão 1, tratados sem e com extrações de dois pré-molares superiores.

AVALIAÇÃO RADIOGRÁFICA PERIAPICAL DOS NÍVEIS DE REABSORÇÃO RADICULAR DE INCISIVOS SUPERIORES APÓS TRATAMENTO ORTODÔNTICO

EFEITO DO TIPO DE SISTEMAS DE CULTIVO NO DESENVOLVIMENTO IN VITRO DE FOLÍCULOS PRÉ-ANTRAIS CAPRINOS ISOLADOS

Avaliação da força de tração em braquetes colados pela técnica indireta com diferentes sistemas de adesão

Fechamento de espaços de molares

ICT/ UNESP: TCC RESUMO

EFEITO DE DIFERENTES MÉTODOS DE REMOÇÃO DE RESINA REMANESCENTE NA RECOLAGEM DE ACESSÓRIOS ORTODÔNTICOS

Login: aptrevizan Senha: AUTOLIGADO: VANTAGENS E DESVANTAGENS - RELATO DE CASO CLÍNICO

CITOTOXICIDADE DOS ELASTÔMEROS UTILIZADOS EM ORTODONTIA: ESTUDO In Vitro SOBRE VIABILIDADE CELULAR

Universidade Estadual do Centro-Oeste Guarapuava PR Reconhecida pelo Decreto Estadual n 3.444/97 PROGRAMA DE PÓS-GRADUAÇÃO EM BIOENERGIA

Aparelho de Protrusão Mandibular FLF

MIGUEL ARAUJO CARNEIRO JÚNIOR

UNIVERSIDADE FEDERAL DO RIO GRANDE DO SUL

ESTUDOS QUE COMPARARAM DIFERENTES EXERCÍCIOS NA MUSCULAÇÃO

Análise comparativa da relação carga/deflexão de fios retangulares de NiTi convencionais e termoativados

Má oclusão Classe II, 2ª Divisão de Angle, com sobremordida acentuada

Statistical analysis of unconventional bituminous mixtures performance based on 4PB Tests

(22) Data do Depósito: 20/06/2014. (43) Data da Publicação: 31/05/2016

INSTITUTO SUPERIOR DE CIÊNCIAS DA SAÚDE EGAS MONIZ

ESTUDO DO DESGASTE ABRASIVO DE AÇO CARBONITRETADO EM DIFERENTES RELAÇÕES AMÔNIA/PROPANO

Avaliação do ângulo nasolabial após o tratamento ortodôntico com e sem extração dos primeiros pré-molares

Estudo comparativo da discrepância nas dimensões dentárias em pacientes portadores de diferentes deformidades esqueléticas

Avaliação in vitro da liberação de níquel por braquetes metálicos

MÁ OCLUSÃO DE CLASSE II COM BIPROTRUSÃO TRATADA COM COMPENSAÇÃO DENTARIA RELATO DE CASO CLÍNICO

Estudo comparativo das dimensões transversais dos arcos dentários entre jovens com oclusão normal e má oclusão de Classe II, 1ª divisão

DISPOSITIVO BANDELETE

Influência das Variantes Genéticas Funcionais do Sistema Renina-Angiotensina na Doença Arterial Coronária.

GENOTOXICIDADE DOS ELASTÔMEROS ORTODÔNTICOS: ESTUDO IN VITRO

Pró-Reitoria Acadêmica Escola de Saúde e Medicina Programa de Pós-Graduação Stricto Sensu em Gerontologia

EXTRAÇÃO ATÍPICA EM TRATAMENTO ORTODÔNTICO ATYPICAL EXTRACTION IN ORTHODONTIC TREATMENT

ESTIMATIVA DE VIDA SOB FLUÊNCIA DE FIOS DE POLIETILENO DE ALTO MÓDULO ATRAVÉS DA METODOLOGIA DE LARSON- MILLER

ESTUDO DO PROCESSO DE LAMINAÇÃO DE FIOS DE COBRE: INFLUÊNCIA DAS PROPRIEDADES MECÂNICAS E DA TEMPERATURA DE PROCESSAMENTO

Andre Luis Ferreira da Silva. Estabilidade dos Betas de Ações no Mercado Brasileiro: Uma Avaliação em Períodos de Alta Volatilidade

Confecção e instalação do Sky Hook

Tabela 1 Características dos voluntários selecionados para o ensaio de bioequivalência. D.P.I. = desvio do peso ideal; D.

Universidade do Estado do Rio de Janeiro Centro Biomédico Faculdade de Odontologia. Daniel Jogaib Fernandes

06/07/12 OBJETIVOS DE TRATAMENTO. Saúde periodontal. Segundo TWEED, deve-se realizar uma retração anterior de 2,8mm. Robert C.

Cap 03: Dilatação térmica de sólidos e líquidos

RELAÇÃO ENTRE MOBILIDADE CERVICAL, SENSIBILIDADE LOMBAR E O SISTEMA NERVOSO AUTÔNOMO EM INDIVÍDUOS SAUDÁVEIS: UM ESTUDO TRANSVERSAL.

Experimentos. Introdução. Vantagens. Exemplo. Cleidson de Souza. LABES - DI - UFPA

1. Apresentação Objetivos Introdução O Solo Contaminação do solo... 6

UNIVERSIDADE CATÓLICA DE PERNAMBUCO PRÓ-REITORIA DE ENSINO, PESQUISA E EXTENSÃO PROESPE MESTRADO EM ENGENHARIA CIVIL

EFEITOS DA TERMORRETIFICAÇÃO NO PROCESSO DE ACABAMENTO DE MADEIRAS

Filosofia do Tratamento Ortodôntico com Braquetes Autoligáveis Passivos ROGÉRIO SCHMIDT ARMANDO

Transcrição:

COMPARAÇÃO DA DEGRADAÇÃO DA FORÇA DE ELÁSTICOS ORTODONTICOS INTERMAXILARES DE LÁTEX E SINTÉTICOS QUANDO SUBMETIDOS À DISTENSÃO EM SALIVA ARTIFICIAL Comparison of force degradation intermaxilary latex and synthetic orthodontic elastics distended in artificial saliva Jéssica Laís Sampaio Dos Santos 1 Ana Cláudia De Castro Ferreira Conti 2 Renata Rodrigues De Almeida-Pedrin 3 Daniela Lasmar De Mendonça 3 Danilo Pinelli Valarelli 3 1 Universidade do Sagrado Coração USC, Bauru, SP, Brasil 2 Departamento de Otodontia Centro Universitário do Norte - UNINORTE, Manaus, AM, Brasil 3 Departamento de Ortodontia - Universidade do Sagrado Coração USC, Bauru, SP, Brasil Recebido em: 07/01/2018 Aceito em: 29/03/2018 SANTOS, Jéssica degradação da força de e sintéticos quando SALUSVITA, Bauru, v. 37, RESUMO Introdução: os elásticos intermaxilares sintéticos surgiram como uma alternativa para uso ortodôntico em pacientes com sensibilidade ao látex, porém, diferenças podem ser observadas quando comparados aos elásticos naturais de látex. Objetivo: comparar a quantidade de degradação de força dos elásticos intermaxilares sintéticos e de látex quando distendidos em saliva artificial, a fim de buscar parâmetros clínicos para o uso de um protocolo sobre a frequência de troca desses elásticos nas terapias ortodônticas em pacientes com sensibilidade ao látex ou não. Metodologia: foram utilizados dois 7

grupos contendo 30 elásticos cada. O grupo 1 com 30 elásticos de látex da marca Morelli de força média e diâmetro de 5/16 e o grupo 2, 30 elásticos sintéticos, sem látex, também da marca Morelli de força média e diâmetro de 5/16. Eles foram distendidos 4cm e submersos em saliva artificial a 37 graus Celsius e tiveram força mensurada com dinamômetro ortodôntico ao início e nos intervalos de 24, 48, 72 e 120 horas após a imersão. A avaliação da degradação da força foi realizada calculando o percentual de força perdida em relação à força inicial em cada intervalo de tempo, para cada grupo testado separadamente e também entre eles. Resultados e Discussão: a média de valores dos elásticos tanto de silicone quanto de látex teve um percentual parecido quanto à degradação de forças, visto que após as primeiras 24 horas ocorreu o maior declínio de força, de aproximadamente 11% ambos os elásticos. Após 48 horas esse percentual não se alterou significativamente. Conclusão: elásticos devem ser trocados em até 48 horas para que a força aplicada se mantenha em índices aceitáveis. SANTOS, Jéssica Palavras-chave: Elastômeros. Degradação de força. Elásticos intermaxilares. ABSTRACT Introduction: synthetic intermaxillary elastics have emerged as an alternative for orthodontic use in patients with latex sensitivity, but differences can be observed when compared to natural latex elastics. Objective: compare the amount of force degradation of synthetic intermaxillary elastics and latex when distended in artificial saliva in order to find clinical parameters for the use of a protocol on the frequency of exchange of these elastics in orthodontic therapies in patients with latex sensitivity or not. Method: for this, two groups containing 30 elastics were used. Group 1 with 30 medium strength and diameter 5/16 Morelli latex elastics and group 2, 30 synthetic latex-free elastics, also of the medium strength and 5/16 diameter Morelli brand. They were stretched 4cm and submerged in artificial saliva at 37 degrees Celsius and had strength measured with orthodontic dynamometer at the beginning and at the intervals of 24, 48, 72 and 120 hours after immersion. The force degradation assessment was performed by calculating the percentage of force lost in relation to the initial force at each time interval, for each group tested separately and also between them. Results and discussion: the mean elastic values of both silicone and latex had 8

SANTOS, Jéssica a similar percentage for the degradation of forces, since after the first 24 hours the greatest force decline occurred, of approximately 11% both elastics. After 48 hours this percentage did not change significantly. Conclusion: elastics should be changed within 48 hours so that the force applied remains at acceptable rates. Keywords: Elastomers. Force degradation. Synthetic intermaxillary elastics. INTRODUÇÃO Materiais elásticos são amplamente utilizados na ortodontia desde a década de 60 (ARAUJO; URSI, 2006). Sua propriedade elástica é o que permite que este seja um excelente coadjuvante na mecânica ortodôntica onde a força recíproca é desejada. Existem dois tipos de elásticos ortodônticos: os de látex e os sintéticos. Ambos podem ser utilizados como elásticos intermaxilares para correção da relação antero-posterior, da linha média e da intercuspidação (LORIATO et al., 2006). Porém, para os pacientes que apresentam reação alérgica ao látex, somente os elásticos sintéticos podem ser usados no tratamento ortodôntico. Esses elásticos possuem a característica de degradação de força, ou seja, com o decorrer do tempo, a magnitude de força inicialmente empregada reduz e, com isso, a movimentação dentária pode diminuir ou cessar, podendo aumentar o tempo de tratamento (ARAUJO; URSI, 2006; BISHARA; ANDREASEN, 1970; CABRERA et al., 2003; HENRIQUES et al., 2003). Isso acontece em ambos os tipos de elásticos, sendo os sintéticos os que têm os maiores índices de redução de força (CABRERA et al., 2003; FERNANDES et al., 2011; OLIVEIRA et al., 2011; RUSSELL et al., 2001). Diversos fatores podem influenciar a perda de força dos elásticos intermaxilares: o meio salivar, temperatura bucal e movimentos mandibulares (ARAUJO; URSI, 2006). A influência do meio ao qual o elástico é mantido foi avaliada e trabalhos mostraram que os elásticos quando testados em meio úmido sofrem maior degradação de força ao longo do tempo do que quando testados em meio seco (BISHARA; ANDREASEN, 1970; STEVENSON; KUSY, 1994; WANG et al., 2007). Além disso, a elevação da temperatura também foi considerada um fator agravante na redução de carga gerada pelos elásticos (STEVENSON; KUSY, 1994). Assim, estudos foram realizados em meio aquoso a 37 C, simulando as condições bucais e mostraram que a saliva artificial é o 9

único meio que afeta significantemente todos os elastômeros, com alto ou baixo módulo de elasticidade (BISHARA; ANDREASEN, 1970; VON FRAUNHOFER et al., 1992), Um dos primeiros estudos realizados avaliou a degradação de força dos elásticos durante movimentos funcionais da mandíbula, e constatou que no decorrer de um dia há uma perda de 30% das propriedades elásticas e para manter as forças mais constantes, sugere a troca diária dos elásticos (BERTRAN, 1931). Já Chaconas et al. (1978), relataram que as forças ideais se mantinham por cerca de 48 horas, não justificando assim a troca diária dos elásticos. Pesquisas de Moris et al. (2009) avaliaram a degradação de força dos elásticos de diversos diâmetros, imersos em saliva artificial e submetidos à distensões que simulavam movimentos mandibulares, e concluíram que em todos os casos analisados, a degradação de força foi maior nas duas primeiras horas e recomendaram a troca para elásticos 3/16 força pesada a cada 72 horas. Oliveira et al. (2011), concluíram que a maior quantidade de degradação de força dos elásticos sintéticos ocorre nas primeiras 24 horas (até 70% de perda) e recomendaram uso de tabelas de referência para conduzir a melhor maneira de realizar a troca do elástico intermaxilar. A literatura ainda aponta divergência de resultados sobre a degradação da força de elásticos intermaxilares, o que prejudica a criação de um protocolo geral de troca desses durante o tratamento. Atribui- -se essa incoerência e disparidade de protocolos para o uso desses elásticos devido aos diferentes métodos experimentais e tipos de materiais avaliados. Logo, acredita-se que ao se comparar a degradação de forças entre os elásticos de látex e sintéticos seja possível estabelecer um protocolo de uso em relação ao tempo de troca desses elásticos no tratamento ortodôntico, mantendo-se assim a força ótima para a movimentação dentária. SANTOS, Jéssica MATERIAL E MÉTODOS Foram selecionados de forma aleatória elásticos intermaxilares, a partir de embalagens seladas e dentro do prazo de validade, 5,16 de diâmetro que foram divididos em dois grupos: GRUPO 1: 30 elásticos de látex de 5/16 de diâmetro, de força média (Morelli- Sorocaba/SP - Brasil). GRUPO 2: 30 elásticos sintéticos (sem látex) de 5/16 de diâmetro de força média (Morelli- Sorocaba/SP - Brasil). Em ambos os grupos, os elásticos foram distendidos 4 cm, e mantidos por dispositivos simples com duas pontas de metal para prender 10

SANTOS, Jéssica os elásticos (figura 1), simulando o uso contínuo dos elásticos por parte dos pacientes, feito isso, sua força foi mensurada por meio de dinamômetro ortodôntico de precisão (Zeusan, Campinas/SP Brasil) (figura 2) e anotada em uma planilha feita no software Excel para Windows da Microsoft. Após isto, estes dispositivos de apreensão dos elásticos foram imersos em saliva artificial (figura 3). Os recipientes permaneceram em estufa a 37 C (figura 4), simulando o ambiente bucal. Após períodos de 24h, 48h 72h e 120h, as forças foram novamente mensuradas e anotadas. Fonte: Autor. Figura 1 - Dispositivo para distensão dos elásticos. 11

SANTOS, Jéssica Fonte: Autor. Figura 2 - Dinamômetro ortodôntico de precisão (Zeusan, Campinas/SP Brasil). Fonte: Autor. Figura 3 - Recipiente para imersão dos dispositivos. 12

SANTOS, Jéssica Fonte: Autor. Figura 4 - Estufa na temperatura de 37ºC, simulando a temperatura do meio bucal. RESULTADOS A avaliação da degradação da força foi realizada calculando o percentual de força perdida em relação à força inicial em cada intervalo de tempo para cada grupo e também entre eles e os resultados estão representados na Tabela 1. Tabela 1 - Distribuição dos valores das forças mensuradas e percentuais médios de degradação para os tipos elásticos 5/16 por tempo Silicone Látex Média de força (g) Degradação (%) Média de força (g) Degradação (%) Inicial 146,83-164,33-24 H 131,5 10,44 147,17 10,44 48 H 126,33 13,96 144,83 11,87 72 H 118,67 19,18 134,67 18,05 120 H 118,67 19,18 129,17 21,40 13

A média de valores dos elásticos tanto de silicone quanto de látex teve um percentual parecido quanto a degradação de forças, visto que após as primeiras 24 horas ocorreu o maior declínio de força, de aproximadamente 11% ambos os elásticos. DISCUSSÃO Os elásticos são parte fundamental de quase qualquer tratamento ortodôntico e são utilizados tanto inter quanto intramaxilar. Estes dispositivos possuem vários fatores que favorecem o seu uso, como por exemplo o baixo custo, versatilidade, biocompatibilidade, e na parte funcional eles agem para correção da relação ântero-posterior, da linha média e da intercuspidação (MORIS et al., 2009). Porém sabe-se que esses materiais não apresentam uma força constante como o desejado, sofrendo uma degradação ao longo do tempo, o que pode ser prejudicial ao tempo estimado de tratamento. Nesta pesquisa foram avaliados elásticos sintéticos e de látex de diâmetro 5/16 nos tempos 24, 48, 72 e 120 horas após a sua imersão na saliva artificial a 37ºC. Como resultado observamos que há uma perda de força maior nas primeiras 24 horas em ambos os grupos (11%). Bertran et al. (1931) afirmou que os elásticos perdem aproximadamente 1/3 de suas propriedades ao longo do dia. Araújo e Ursi (2006) analisaram dez amostras de elásticos sintéticos dos fabricantes Morelli, Ormco, Gac, TP, Unitek. Os elásticos foram distendidos 20mm em placas metálicas com pinos e imersos em saliva artificial à 37ºC e a distensão foi mensurada após ½, 1, 6, 12, 24, 48 horas, 7, 14, 21, 28 dias. Concluiu que os elásticos perderam maior força na primeira hora após o seu estiramento, e que a média perdida após os 28 dias foi semelhante em todas as marcas analisadas. Em ambas pesquisas, a degradação maior ocorreu nas primeiras 24 horas corroborando com o que foi verificado neste trabalho. Bishara et al. (1970), compararam elásticos de plástico e látex por 3 semanas. Relataram uma perda de força nas primeiras 24 horas que se manteve estável nas 3 semanas. Este recomendou que a troca dos elásticos sintéticos não ocorresse diariamente, caso a vantagem fosse uma força remanescente constante em períodos mais longos de tempo. Já Moris et al. (2009) simularam movimentos mandibulares e avaliaram elásticos de diâmetros 1/8, 3/16 e 5/16 de três fabricantes (Morelli, 3M Unitek Corporation e American Orthodontics), imersos em saliva artificial a 37ºC. Observaram que o elástico 1/8 precisa ser trocado a cada 24 horas e já os demais, após 72 horas. SANTOS, Jéssica 14

SANTOS, Jéssica CONCLUSÃO Nas primeiras 24 horas houve um declínio de força de quase 11% em ambos os elásticos e depois de 48 horas a perda foi mínima. A troca dos elásticos deve ter no máximo intervalos de 48 horas para que a força empregada não sofra perdas excessivas. Os elásticos sintéticos e látex sofreram degradações semelhantes, portanto não é o tipo do material que irá definir o sucesso do tratamento. REFERÊNCIAS ARAUJO, F. B. C.; URSI, W. J. S. Estudo da degradação da força gerada por elásticos ortodônticos sintéticos. R Dent Press Ortodon Ortop Facial, Maringá, v. 11, n. 6, 2006. BERTRAN, C. Die krafte der orthodontischen Gummuligatur. Forstchr Orthod, Berlim, v. 1, p. 605-609, 1931. BISHARA, S. E.; ANDREASEN, G. F. A comparison of time related forces between plastic alastiks and latex elastics. Angle Orthod, Lawrence, v. 40, n. 4, p. 319-28, Oct 1970. CABRERA, M. D. C. et al. Elásticos em Ortodontia: Comportamento e Aplicação Clínica. R Dental Press Ortodon Ortop Facial, Maringá, v. 8, n. 1, 2003. CHACONAS, S. J.; CAPUTO, A. A.; BELTING, C. W. Force degradation of orthodontic elastics. CDA J, Sacramento, v. 6, n. 9, p. 58-61, Sep 1978. FERNANDES, D. J. et al. Force extension relaxation of medium force orthodontic latex elastics. Angle Orthodontist, Lawrence, v. 81, n. 5, 2011. HENRIQUES, J. F. C.; HAYASAKI, S. M.; HENRIQUES, R. P. Elásticos Ortodônticos: como Selecioná-los e Utilizá-los de Maneira Eficaz. J Bras Ortodon Ortop Facial, v. 8, n. 48, 2003. LORIATO, L. B.; MACHADO, A. W.; PACHECO, W. Considerações clínicas e biomecânicas de elásticos em Ortodontia. Revista Clínica de Ortodontia Dental Press Maringá, v. 5, n. 1, 2006. MORIS, A. et al. Estudo in vitro da elásticos ortodônticos de látex sob condições dinâmicas. R Dental Press Ortodon Ortop Facial, Maringá, v. 14, n. 2, 2009. 15

OLIVEIRA, C. B. et al. Degradação de forças dos elásticos intermaxilares ortodônticos sintéticos. OrtodontiaSPO, São Paulo, v. 44, n. 5, 2011. RUSSELL, K. A. et al. In vitro assessment of the mechanical properties of latex and non-latex orthodontic elastics. Am J Orthod Dentofacial Orthop, Atlanta, v. 120, n. 1, p. 36-44, Jul 2001. STEVENSON, J. S.; KUSY, R. P. Force application and decay characteristics of untreated and treated polyurethane elastomeric chains. Angle Orthod, Lawrence, v. 64, n. 6, 1994. VON FRAUNHOFER, J. A.; COFFELT, M. T.; ORBELL, G. M. The effects of artificial saliva and topical fluoride treatments on the degradation of the elastic properties of orthodontic chains. Angle Orthod, Lawrence, v. 62, n. 4, p. 265-74, 1992. WANG, T. et al. Evaluation of force degradation characteristics of orthodontic latex elastics in vitro and in vivo. Angle Orthod, Lawrence, v. 77, n. 4, p. 688-93, Jul 2007. WEISSHEIMER, ANDRÉ; LOCKS, ARNO ; MENEZES, LUCIA- NE MACEDO DE ; BORGATTO, ADRIANO FERRETI ; DERE- CH, CARLA D AGOSTINI. In vitro evaluation of force degradation of elastomeric chains used in Orthodontics. Dental Press Journal of Orthodontics, Maringá, v. 18, p. 55-62, 2013. SANTOS, Jéssica 16