EVALUATION OF LATERAL STRAGGLING IN SRIM2012 AND GEANT4 FOR PROTON THERAPY AVALIAÇÃO DO DESVIO LATERAL EM SRIM2012 E GEANT4 PARA PROTONTERAPIA

Documentos relacionados
Lucas de Assis Soares, Luisa Nunes Ramaldes, Taciana Toledo de Almeida Albuquerque, Neyval Costa Reis Junior. São Paulo, 2013

Análise fatorial de um feixe de prótons

A Tool to Evaluate Stuck-Open Faults in CMOS Logic Gates

Service quality in restaurants: an experimental analysis performed in Brazil

Validação da simulação do feixe de prótons

and environmental aspects aspectos socioambientais

CIS 500 Software Foundations Fall September(continued) IS 500, 8 September(continued) 1

SCIENTIA PLENA VOL. 8, NUM

Incerteza, exatidão, precisão e desvio-padrão

DESENVOLVIMENTO MORAL NAS ORGANIZAÇÕES: UM ESTUDO NA ASSOCIAÇÃO DE ALCOÓLICOS ANÔNIMOS

AVALIAÇÃO DA HOMOGENEIDADE DAS FONTES PLANAS DE REFERÊNCIA UTILIZADAS NA CALIBRAÇÃO DE MONITORES DE CONTAMINAÇÃO DE SUPERFÍCIE

AVALIAÇÃO DO SISTEMA DE COLIMAÇÃO DO PROTÓTIPO DE UM TOMÓGRAFO BASEADO EM FEIXE DE PRÓTONS DE BAIXA ENERGIA POR SIMULAÇÕES DE MONTE CARLO.

JOSÉ RICARDO SANCHEZ FILHO ANALYSIS OF THE LONG-TERM EFFECTS OF THE VOLUNTARY OFFER OF THE BID RULE ON STOCKS LISTED IN THE BRAZILIAN STOCK EXCHANGE

Instituto Politécnico de Tomar. Controlo de TCA e outros off-flavours na Cortiça. Relatório de Estágio. Ana Leonor da Costa Vila Mendes

ELISAMA ALVES. ANÁLISE DE IMAGENS NA AVALIAÇÃO DA QUALIDADE DE SEMENTES DE Pinus taeda E Eucalyptus spp

Impressão do Formulário

NCE/10/01761 Decisão de apresentação de pronúncia - Novo ciclo de estudos

As 10 bobagens mais comuns que as pessoas inteligentes cometem (Portuguese Edition)

ASIP Conference 2007

Avaliação do Índice Apoptótico em Adenomas Pleomórficos de Glândulas Salivares

CAPÍTULO. Gonçalves F., Rosane 1 *; Napoleão R., Marcos 2. Universidade Federal de Goiás. Universidade Federal de Goiás

Instrução Normativa nº 10, de 19/12/2018

Prova de Seleção Mestrado LINGUA INGLESA 15/02/2016

INTERACTION DIAGRAMS FOR DESIGN OF CONCRETE-FILLED TUBULAR COLUMNS UNDER FIRE

Princípios de Finanças Corporativas (Portuguese Edition)

UERJ Programa de Pós-graduação em Engenharia Mecânica (PPGEM) Seminary Class

Poder sem limites - o caminho do sucesso pessoal pela programação neurolinguística

DA QUALIDADE DO FEIXE DE ACELERADORES LINEARES*

O PRíNCIPE FELIZ E OUTRAS HISTóRIAS (EDIçãO BILíNGUE) (PORTUGUESE EDITION) BY OSCAR WILDE

Writing Good Software Engineering Research Papers

Como deixar seus cabelos lindos e saudáveis (Coleção Beleza) (Portuguese Edition)

Minimum Fluidization Velocity of mixture of sand and sugarcane bagasse particles

Pesquisa Qualitativa do Início ao Fim (Métodos de Pesquisa) (Portuguese Edition)

Statistical analysis of unconventional bituminous mixtures performance based on 4PB Tests

Princípios de Direito Previdenciário (Portuguese Edition)

Introdução A Delphi Com Banco De Dados Firebird (Portuguese Edition)

As 100 melhores piadas de todos os tempos (Portuguese Edition)

TDD Desenvolvimento Guiado por Testes (Portuguese Edition) Kent Beck

MySQL: Comece com o principal banco de dados open source do mercado (Portuguese Edition)

Cálculo de Índices de Segurança em Sistemas de Energia Elétrica Baseado em Simulação no Domínio do Tempo

Projectos de Consultoria em SAP e Tecnologias Microsoft: Análise e desenvolvimento de soluções de software à medida

Príncipe De Maquiavel E Seus Leitores, O (Portuguese Edition)

ANABELA VIRGÍNIA DOS SANTOS FLORES DA ROCHA ESTIMAÇÃO ROBUSTA EM MODELOS LINEARES DE EQUAÇÕES SIMULTÂNEAS

Métodos Quantitativos e Qualitativos na Engenharia (M2QE) Quantitative and Qualitative Methods in Engineering (QQME)

Software Testing with Visual Studio 2013 (20497)

ALGEBRA 2 PRACTICE FINAL EXAM

MASTER S DEGREE IN INTELLECTUAL PROPERTY ADMISSION EXAM

DEPARTAMENTO DE ENGENHARIA CIVIL E ARQUITETURA

NOVELPRINT É A GRANDE VENCEDORA DO OSCAR MUNDIAL DA ROTULAGEM!

Medicina e Meditação - Um Médico Ensina a Meditar (Portuguese Edition)

DISSERTAÇÃO DE MESTRADO

O Livro de Receitas do Menino Maluquinho - Com as receitas da Tia Emma (Portuguese Edition)

CARGA NUCLEAR EFETIVA A carga nuclear de um átomo é dada pelo número de prótons do núcleo deste átomo e é chamada número atômico (Z).

CARGA NUCLEAR EFETIVA

Aquecimento global Rise of temperature

Potencial da Telemedicina Dentária no diagnóstico oral infantil

2. Fóruns de discussão no contexto educativo Fóruns de discussão como tecnologias de apoio ao ensino e aprendizagem

GERENCIAMENTO DA ROTINA DO TRABALHO DO DIA-A-DIA (EM PORTUGUESE DO BRASIL) BY VICENTE FALCONI

Pesquisa Qualitativa do Início ao Fim (Métodos de Pesquisa) (Portuguese Edition)

Agenda. Cost-effectiveness analysis of vemurafenib compared to dacarbazine for the metastatic melanoma treatment in Brazilian Public Health System

Artigo Original TRATAMENTO DO CÂNCER DE CABEÇA E PESCOÇO NO IDOSO ACIMA DE 80 ANOS

Meditacao da Luz: O Caminho da Simplicidade

Como Falar no Rádio - Prática de Locução Am e Fm (Portuguese Edition)

Performance and Power Consumption Analysis of Full Adders Designed in 32nm Technology

Aspectos Multidisciplinares das Artes Marciais: 1 (Portuguese Edition)

The many faces of science: applied, basic, fundamental, exploratory, innovative,

UNIVERSIDADE FEDERAL DA BAHIA FACULDADE DE MEDICINA DA BAHIA PROGRAMA DE PÓS-GRADUAÇÃO EM CIÊNCIAS DA SAÚDE

UNIVERSIDADE DO SAGRADO CORAÇÃO MILENA CAROLINA SILVA CASTRO OLIVEIRA

Vendors Enquiries for RFP 003/2015

Guia para Formacao de Analistas de Processos: Gestão Por Processos de Forma Simples (Portuguese Edition)

O uso do Biodiesel em Micro-turbinas a Gás: Testes de Desempenho Térmico e Emissões

NORMAS DE FUNCIONAMENTO DOS CURSOS DE LÍNGUAS (TURMAS REGULARES E INTENSIVAS) 2015/2016

Medicina Integrativa - A Cura pelo Equilíbrio (Portuguese Edition)

DINÂMICA DO FÓSFORO EM SISTEMAS DE MANEJO DE SOLOS DANILO RHEINHEIMER DOS SANTOS. (Engenheiro Agrônomo, M.Sc.)

CALIBRAÇÃO DE UMA CÂMARA DE EXTRAPOLAÇÃO PTW EM DOIS SISTEMAS PADRÕES SECUNDÁRIOS, COM FONTES DE 90 Sr+ 90 Y

COBERTURA DE ÁREA COOPERATIVA UTILIZANDO SEGMENTAÇÃO HEXAGONAL

VGM. VGM information. ALIANÇA VGM WEB PORTAL USER GUIDE June 2016

Programa de Pós-Graduação em Modelagem e Otimização, Regional Catalão / UFG

A ENTREVISTA COMPREENSIVA: UM GUIA PARA PESQUISA DE CAMPO (PORTUGUESE EDITION) BY JEAN-CLAUDE KAUFMANN

Revisão Sistemática: Conceitos Básicos

RACHEL PRADO RUSSO DELORENZO NARDI ESTUDO DA CINÉTICA DE LIBERAÇÃO DE GENTAMICINA A PARTIR DE MEMBRANAS DE QUITOSANA

Deficiência mental Síndroma de Down Tipos ou classes de Síndroma de Down Etiologia 9

Comportamento Organizacional: O Comportamento Humano no Trabalho (Portuguese Edition)

TEN CATE. HISTOLOGIA ORAL (EM PORTUGUESE DO BRASIL) BY ANTONIO NANCI

Vaporpunk - A fazenda-relógio (Portuguese Edition)

G4 and Public Outreach Communication

EGAN. FUNDAMENTOS DA TERAPIA RESPIRATÓRIA (EM PORTUGUESE DO BRASIL) BY CRAIG L. SCANLAN

UNIDADE DE PESQUISA CLÍNICA Centro de Medicina Reprodutiva Dr Carlos Isaia Filho Ltda. SAMPLE SIZE DETERMINATION FOR CLINICAL RESEARCH

A STUDY OF THE INFLUENCE OF THE SOLVENTS WATER AND ETHANOL ON THE GEOMETRICAL PROPERTIES OF A PYRIDINE DERIVATIVES

Livro do Desassossego

A ENTREVISTA COMPREENSIVA: UM GUIA PARA PESQUISA DE CAMPO (PORTUGUESE EDITION) BY JEAN-CLAUDE KAUFMANN

School Performance Evaluation in Portugal: A Data Warehouse Implementation to Automate Information Analysis

FRAÇÕES ABSORVIDAS EM ESFERAS DISCRETIZADAS DE VÁRIOS TAMANHOS. Hélio Yoriyaz

MARCELO NIEHUES SCHLICKMANN

Nov Chem Problem Set 10: solution to Problem 2 a) Using the given functions S( R), J '( R), K '( R ), a plot of E( R) 1/ 2 (which reach

Emissions of the Brazilian power sector in case of a low-hydrology scenario until 2030

Universidade Estadual do Centro-Oeste Guarapuava PR Reconhecida pelo Decreto Estadual n 3.444/97 PROGRAMA DE PÓS-GRADUAÇÃO EM BIOENERGIA

FEDERAL UNIVERSITY OF RIO DE JANEIRO THIAGO BRANDÃO DA CUNHA

Transcrição:

Nº 30, volume IX, artigo nº 7, Julho/Setembro 2014 D.O.I: 10.6020/1679-9844/3007 EVALUATION OF LATERAL STRAGGLING IN SRIM2012 AND GEANT4 FOR PROTON THERAPY AVALIAÇÃO DO DESVIO LATERAL EM SRIM2012 E GEANT4 PARA PROTONTERAPIA Francisco Roberto Cassetta Junior¹, João Antônio Palma. Setti², Edney Milhoretto³, Hugo R.Schelin 4, Ivan Gennadievitch Evseev 5 ¹ Universidade Tecnológica Federal do Paraná (UTFPR), Curitiba(PR), Brazil, franciscoroberto.cassetta@polimi.it ² Universidade Tecnológica Federal do Paraná(UTFPR), Curitiba(PR), Brazil, setti@utfpr.edu.br 3 Universidade Tecnológica Federal do Paraná(UTFPR), Curitiba(PR), Brazil, edney.milhoretto@gmail.com 4 Hospital Pequeno Príncipe, Curitiba(PR), Brazil, schelin@utfpr.edu.br 5 Universidade Tecnológica Federal do Paraná(UTFPR), Francisco Beltrão(PR), Brazil, ivan_evseev@hotmail.com Abstract: The modality of radiotherapy with protons shows promising results compared to conventional treatment with photons. There are softwares, such as GEANT4 and SRIM, which allow simulations of passages of heavy particles through matter, thus making it possible to obtain useful results for specific studies in this area. Its importance comes from its relative simplicity of use mainly due to the high cost of hadron accelerators. The analysis of the parameters calculated by simulations and their levels of uncertainty in the region of the Bragg peak will be essential to future development stages of treatment plans with proton beam. This work presents some simulations about the trend of increase in mean lateral deviation (in the Bragg peek ISSN: 16799844 - InterSciencePlace - Revista Científica Internacional Páginas 122 de 197

region) with increasing energy of the incident beam. Keywords: Proton therapy. Simulations. SRIM2012. GEANT4. Resumo: A modalidade de radioterapia com prótons vem trazendo resultados promissores comparados ao tratamento convencional por fótons. Há softwares, como o SRIM2012 e GEANT4, que permitem simulações de passagem de partículas pesadas pela matéria, tornando possível a obtenção de resultados úteis para estudos específicos nessa área. Sua importância vem de sua simplicidade de uso frente ao alto custo dos aceleradores de hádrons. A análise dos parâmetros calculados por simulações e seus níveis de incerteza na região do pico de Bragg será essencial para o futuro aprimoramento de planos de tratamento em protonterapia. Este trabalho apresenta a tendência do aumento do desvio lateral com o aumento inicial do feixe na região de máximo alcance dos prótons(pico de Bragg). Palavras-chave: Simulações. Protonterapia. SRIM2012. GEANT4. 1. INTRODUCTION The new form of radiotherapy with proton beam has brought quite promising and superior results when compared to conventional treatment which uses photons (KOZAK et al. 2007; NICHOLS et al. 2012; ROMBI et al. 2012), especially for sparing critical structures adjacent to the tumor, as in the case of eyes, brain and spinal canal due to the fact that it has no exit dose. With improved treatments, there is a high quality of life expectancy, increasing for patients in general. By means of simulations in SRIM2012 and GEANT4, there is the possibility of analyzing heavy particles passing through matter (AGOSTINELLI et al., 2003), for example, in a phantom composed of specific densities materials, close to the actual human structures. Data outputs as transmitted ions are then generated, maximum range in the target, lateral deviation and energy of the ion. Based on this new technology, one can do simulations and look forward to increasingly effective and precise treatments allied with tomography images, which is currently extensively studied due to the difficulty of knowing the not homogeneous protons pathways (PAGANETTI, 2012). There are formalisms that covering three times the value of the standard deviation, can predict the mean path of protons with an uncertainty of 0.6 ISSN: 16799844 - InterSciencePlace - Revista Científica Internacional Páginas 123 de 197

mm in a homogeneous water cube (PENFOLD, 2010).So stands the need for simulations with Monte Carlo method to be carried out in order to improve the image reconstruction algorithms, since having better knowledge and control of processes that involve distortions of the most likely path of protons (MLP), would affect the density, thus the image quality. The high cost of proton accelerators is certainly a limiting factor of the wide availability of this new kind of treatment. The protons accelerator, in general, is more robust, since linear accelerators currently used in radiotherapy, with photons and electrons do not have an electric field strong enough to accelerate heavy beams and occupy a suitable physical space for hospital use. This is one of the most important reasons to study by means of simulations before purchasing or designing a prototype. One day, it might be possible to make simulations accurate and efficient enough to be used simultaneously with treatment (PERL et al., 2012). 2. OBJECTIVES 2.1 General objective - Evaluation of lateral deviation in the interaction of proton beams for energies of 63, 65, 70, 75, 80, 85, 90, 95 and 98 MeV with a phantom of the male pelvic region and with a water block, through simulations with the computational codes SRIM2012 and GEANT 4, respectively. 2.2 Specific objectives - Evaluate the variable straggling (lateral deviation) for the set of a thousand protons in each beam energy level for SRIM. - Evaluate the variable straggling (lateral deviation) for the set of a twenty thousand protons in each beam energy level for GEANT4. - Relate beam energy and uncertainty in the lateral deviation in the Bragg peak ISSN: 16799844 - InterSciencePlace - Revista Científica Internacional Páginas 124 de 197

region. 3. METHOD 3.1 SRIM Firstly, the target is modeled using layers as SRIM2012 works. This software contains a library of elements that simulate human tissues and biological structures. We chose to model the pelvic region of a male individual to observe the behavior of the proton beam in a possible treatment for prostate cancer with beams from 63 to 98 MeV. The final structure of the phantom has a depth of approximately 11.5 cm, and takes into account the passage of the beam in a sequence of layers of different densities and thicknesses, such as skin, adipose tissue, muscle tissue, bone, prostate, and air, as shown in Figure 1. Having the target set, it was possible for each of the energies of the proton beam (63-98 MeV), to perform the process of irradiation of the target by a set of 1000 protons sent one by one. Being the choice of energies purposeful to cover the entire region of the prostate in a possible composition beam, and, for each process, one image was generated representing the number of protons interacting with the environment and its maximum reach. ISSN: 16799844 - InterSciencePlace - Revista Científica Internacional Páginas 125 de 197

Figure 1. Initial Setup of SRIM2012 simulation. Source: The author. 3.2 GEANT An algorithm that contains a water block with a silicon detector there through in the horizontal plane is used. Beams with twenty thousand protons for each energy previously chosen are sent and the detector returns the value of the lateral deviation of each proton. The scheme is illustrated in Figure 2. Figure 2. Water block traversed by a proton beam. Source: The author. ISSN: 16799844 - InterSciencePlace - Revista Científica Internacional Páginas 126 de 197

4. PROTON-MATTER INTERACTION A proton beam passing through the phantom, will interact with electrons and atomic nuclei via Coulomb force, and collisions with these nuclei are also possible, although unlikely. The inelastic collisions in which the proton transfer some of its kinetic energy to the electrons produce ionizations and excitations in the atoms, so the dose absorbed by tissue. For being heavier than the electron, the proton beams are scattered in smaller angles, thus maintaining a more concise aspect. In its path, this beam transfers part of its energy (E) over a certain length traversed in the medium (x) which can be calculated in the form of LET (linear energy transfer) and is expressed as a function of -de/dx (Khan, 2009). It is then noted that the lower the speed, the greater the energy transfer to the region.therefore, we can explain the dose near the peak of maximum beam range, known as the Bragg peak (Figure 3). Figure 3. Damage graphic for the 90 MeV beam. Source: The author. 5. RESULTS Results were then obtained from interactions of the one hundred eighty-nine thousand protons simulate (Table 1). In this study was prioritized the analysis of average lateral deviation (average straggling) of the group of particles for each energy previously specified. The data was analyzed, and using the program STATISTICA10, the average ISSN: 16799844 - InterSciencePlace - Revista Científica Internacional Páginas 127 de 197

deviation of this behavior as a function of the different energies of the beams (Figure 4 and 5) was correlated graphically, and also presented model linearizations. Energy(MeV) σ Water(mm) σ Prostate(mm) 63 0.13509 0.45501 65 0.07547 0.47907 70 0.16130 0.53505 75 0.20449 0.74522 80 0.37203 0.64776 85 0.15277 0.71651 90 0.37013 0.93441 95 0.71945 0.78996 98 0.69115 0.92147 Table 1. Standard Deviation. Source: The author. 5.1 SRIM data: ISSN: 16799844 - InterSciencePlace - Revista Científica Internacional Páginas 128 de 197

Figure 4. Graph representing the standard deviation as a function of beam energy for the prostate treatment simulation. 5.2 GEANT4 data: ISSN: 16799844 - InterSciencePlace - Revista Científica Internacional Páginas 129 de 197

Figure 5. Graph representing the standard deviation as a function of beam energy for the water block simulation. 6. DISCUSSION There have been several simulations and assessment of the uncertainties in the average lateral deviation for each specified energy. As can be seen in Figures 4 and 5, the mean lateral deviation tends to be higher with increasing beam energy as well as in papers (MA, 2007) and (GARCIA-MOLINA, 2012), which corroborate this proposition also with experimental data. It was also presented in this study a linearization of variables that relates the energy (MeV) and mean lateral deviation, showing a correlation level in approximately 92%. In Figures 6 and 7 we can observe the increase in deviation: ISSN: 16799844 - InterSciencePlace - Revista Científica Internacional Páginas 130 de 197

Figure 6. Lateral deviation and maximum range for proton beam of 65 MeV Figure 7. Lateral deviation and maximum range for proton beam of 95 MeV Some of these uncertainties are epistemic, as pointed out by Pia (PIA et al., 2010), regarding the differences in modeling approaches, validations, experimental parameters, and the most significant, modeling multiple scattering in beam line. Therefore it can be noted that the Bragg peak has significant lateral uncertainties that must be taken into account when setting an assessment of a composition of beams for treatment via proton therapy. ISSN: 16799844 - InterSciencePlace - Revista Científica Internacional Páginas 131 de 197

REFERENCES Agostinelli, S. et al. Geant4 a simulation toolkit. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 506(3), p. 250-303, 2003. Garcia-Molina, R. et al. Role of the interaction processes in the depth-dose distribution of proton beams in liquid water. Journal of Physics: Conference Series, p. 373, 2012. Khan, Faiz M. Physics of Radiation Therapy, (Fourth ed.): Wolters Kluwer Lippincott Willians \& Wilkin, 2009. Kozak, K. R. et al. Dosimetric feasibility of hypofractionated proton radiotherapy for neoadjuvant pancreatic cancer treatment. Int J Radiat Oncol Biol Phys, 68(5), p.1557-1566, 2007. L. Ma, Y. et al.. Energy loss and straggling of MeV ions through biological samples. Journal of Applied Physics, p. 102-108, 2007. Pia, M. G. et al. Physics-related epistemic uncertainties in proton depth dose simulation. Nuclear Science, IEEE Transactions, 57(5), 27, 2010. Nichols, R. C. et al. Protons offer reduced normal-tissue exposure for patients receiving postoperative radiotherapy for resected pancreatic head cancer. Int J Radiat Oncol Biol Phys, 83(1), p. 158-163, 2012. Paganetti, H. Proton therapy physics, CRC Pess, 2012. Penfold, S. N. Image reconstruction and Monte Carlo simulations in the development of proton computed tomography for applications in proton radiation therapy. (Doctor of Philosophy), University of Wollongong, 2010. Perl, J. et al. TOPAS: an innovative proton Monte Carlo platform for research and clinical applications. Med Phys, 39(11), p. 6818-6837, 2012. Rombi, B. et al. Proton radiotherapy for pediatric Ewing's sarcoma: initial clinical outcomes. Int J Radiat Oncol Biol Phys, 82(3), p. 1142-1148, 2012. SOBRE OS AUTORES Francisco Roberto Cassetta Junior - Possui mestrado em Engenharia Biomédica pela Universidade Tecnológica Federal do Paraná, Graduação em Física Pela ISSN: 16799844 - InterSciencePlace - Revista Científica Internacional Páginas 132 de 197

Universidade Federal de Santa Catarina. Atualmente é doutorando do Departamento de Bioengenharia do Politecnico di Milano. Tem experiência na área de Física, com ênfase em Física Médica. João Antônio Palma Setti - Possui Doutorado em Engenharia Elétrica pela Universidade Tecnológica Federal do Paraná, Mestrado em Engenharia Elétrica pela Universidade Tecnológica Federal do Paraná, Graduação em Engenharia Elétrica pela Universidade Federal do Paraná, Licenciatura em Eletrônica e Eletrotécnica pela Universidade Tecnológica Federal do Paraná e Licenciatura em Mecânica pela Universidade Tecnológica Federal do Paraná. Atualmente é Professor do Programa de Pós-Graduação em Engenharia Biomédica da Universidade Tecnológica Federal do Paraná. Edney Milhoretto - Possui graduação em Tecnologia em Radiologia pela Universidade Tecnológica Federal do Paraná - UTFPR (2006),mestrado em Engenharia Elétrica e Informática Industrial pela UTFPR (2007), e doutorado em Engenharia Elétrica e Informática Industrial pela UTFPR (2013). Hugo Reuters Schelin - Possui graduação em Física pela Universidade Federal do Paraná (1973), mestrado em Física pela Universidade de São Paulo (1979), doutorado em Física pela Universidade de São Paulo (1985) e pós-doutorado na Michigan State University (1986-1988). Ivan Gennadievitch EVSEEV - Ivan EVSEEV concluiu o Doutorado em Física e Matemática pela Universidade Estatal de Kharkov / Instituto de Física e Tecnologia de Kharkov (Ucrânia), em 1989. A tese dele foi desenvolvida na área de Física de Núcleo Atômico e Partículas Elementares. ISSN: 16799844 - InterSciencePlace - Revista Científica Internacional Páginas 133 de 197