Percutaneous Leads. Directions for Use



Documentos relacionados
Memory Module MMF-02. Modulo de Memoria MMF-02. Módulo de Memória MMF-02 CFW70X

Motor PTC Kit. Kit PTC del Motor. Kit PTC do Motor SSW-07 / SSW-08

Versão: 1.0. Segue abaixo, os passos para o processo de publicação de artigos que envolvem as etapas de Usuário/Autor. Figura 1 Creating new user.

Thank you for using Shepherd 240 Biometric Fingerprint Lock. Please read this Installation Manual carefully before attempting

hdd enclosure caixa externa para disco rígido

VGM. VGM information. ALIANÇA VGM WEB PORTAL USER GUIDE June 2016

Current Measurement Unit - UMC Unidad de Medición de Corriente - UMC Unidade de Medição de Corrente - UMC

Stick Up Cam Battery

CRIMP OD & PRODUCT GUIDE HOSE ID

Manual de instruções para Caixa Coletora Johnson Pump

SATA 3.5. hd:basic. hdd enclosure caixa externa para disco rígido

M (02) / 01-Apr-12. Instructions for Use ENGLISH. Instrucción de uso ESPAÑOL. Instrução de uso PORTUGUES

INSTALLATION GUIDE MANUAL DE INSTALAÇÃO MANUAL DE INSTALACIÓN

Kit Tecsystem for MVW-01. Kit Tecsystem para MVW-01. Kit Tecsystem Installation, Configuration and Operation Guide

Select a single or a group of files in Windows File Explorer, right-click and select Panther Print

2/4 BD8201FM. Lot No. REV. A

Manual de instruções para Sifões VETUS e Johnson Pump

User Guide Manual de Utilizador

Installation Instructions

Intellectual Property. IFAC Formatting Guidelines. Translated Handbooks

ÍNDICE PORTUGUÊS INDEX ENGLISH

Motors Automation Energy Transmission & Distribution Coatings

Motors Automation Energy Transmission & Distribution Coatings. Bluetooth Communication Module. Módulo de Comunicación Bluetooth

MINIKIT mg/l Na 2 SO 3 L EN PT ES. Sulfite HR Sulfito HR Sulfito HR

INSTALLATION GUIDE MANUAL DE INSTALAÇÃO MANUAL DE INSTALACIÓN

Aqui pode escolher o Sistema operativo, e o software. Para falar, faça download do Cliente 2.

Easy Linux! FUNAMBOL FOR IPBRICK MANUAL. IPortalMais: a «brainware» company Manual

ÍNDICE PORTUGUÊS INDEX ENGLISH

Computador móvel Dolphin TM Guia Rápido de Instalação

VGM. VGM information. ALIANÇA VGM WEB PORTAL USER GUIDE September 2016

NORMAS PARA AUTORES. As normas a seguir descritas não dispensam a leitura do Regulamento da Revista Portuguesa de Marketing, disponível em

Captuvo SL22/42. Guia rápido de instalação. Estojo corporativo para ipod touch 5 e iphone 5 da Apple. CAPTUVO22-42-BP-QS Rev A 09/13

VC Series Round Vinyl Caps

PROCEDIMENTOS NECESSÁRIOS ANTES DE UTILIZAR O EQUIPAMENTO. Instalação do Rasther PC. Habilitação das Montadoras

SONDA DE ÁGUA QUENTE SANITÁRIA

SAP Best Practices Informações sobre disponibilidade e download para Clientes SAP e Parceiros SAP. Know-how setorial e global pré-configurado

Operação de Instalações Marítimas

Sistemas Operativos - Mooshak. 1 Mooshak. in fct.ualg.pt/. mooshak.deei.fct.ualg.pt/.

Instalação do encosto. Recursos. Como usar os tubos adaptadores. Estrutura do produto. Sistema de Som

A Aviação no Comércio Europeu de Licenças de Emissão Especificidades para pequenos emissores

USB Communication Kit Kit de Comunicación USB Kit de Comunicação USB SSW-06

RcPDV Rica Informática

SRW 01-HMI. Remote Keypad (HMI) HMI Remoto HMI Remota. Installation Guide Guía de Instalación Guia de Instalação. English / Español / Português

Accessing the contents of the Moodle Acessando o conteúdo do Moodle

Vendors Enquiries for RFP 003/2015

Métodos Formais em Engenharia de Software. VDMToolTutorial

MANUAL DE MONTAGEM ASSEMBLY INSTRUCTIONS INSTRUCCIONES DE MONTAJE COD BR: BPP 21 COD US: 3AMC V : 00

Serviços: API REST. URL - Recurso

GEAR PUMPS RECOMMENDATIONS BEFORE START-UP

BR localization: Hotfix 003. Technical documentation Documentação Técnica Version Dec 12, de Dezembro de 2018

SONDA CASCATA. Avisos preliminares CONTEÚDO FERRAMENTAS RECOMENDADAS NEXPOLAR

NOVO SISTEMA DE CORREIO ELETRONICO PARA OS DOMINIOS ic.uff.br & dcc.ic.uff.br

WATER MATTRESS MASSAGE SYSTEM 20439

2 Categorias Categories Todas as categorias de actividade são apresentadas neste espaço All activity categories are presented in this space

KME Kit. Size 8 and 8E. Kit KME. Tamaño 8y8E. Kit KME. Mecânica 8e8E. KME Kit. Kit KME. Kit KME. Installation Guide. Guía de Instalación

Completing your Participant Agreement Como preencher o Contrato de Participação

1. Product Name. 2. Product Code. 3. Colour. 4. Brief Description. 5. Contents. 6. Snoezelen Stimulations. Switch Adapted Fibre Optic Lamp

User Manual. Linksys PAP2 Broadband Phone Service. Linhagratuita grupo csdata

Instruções de Montagem. Assembly instructions. Montageanleitung

SOUTHPAW WEIGHTED SHOE POCKETS MEDIUM 18792

MANUAL DE MONTAGEM ASSEMBLY INSTRUCTIONS INSTRUCCIONES DE MONTAJE COD BR: BPP 70 COD US: 133AMC V : 00

Motors Automation Energy Transmission & Distribution Coatings. Bluetooth Communication Module. Módulo de Comunicación Bluetooth

ADISTEC SUPPORT PROGRAM PREGUNTAS FRECUENTES FREQUENTLY ASKED QUESTIONS PERGUNTAS FREQUENTES PAG PAG 3 PAG 4

Symantec & Jogos Olímpicos Rio Julho de 2015

INSTALLATION GUIDE MANUAL DE INSTALAÇÃO MANUAL DE INSTALACIÓN

INSTALLATION GUIDE MANUAL DE INSTALAÇÃO MANUAL DE INSTALACIÓN

Uma solução possível para garantir, em ambiente APEX, a consistência duma estrutura ISA total e disjuntiva.

NORMAS DE FUNCIONAMENTO DOS CURSOS DE LÍNGUAS (TURMAS REGULARES E INTENSIVAS) 2015/2016

Guia de Instalação Rápida TEW-430APB

Parts of the Solar Charger. Charging the Solar Battery. Using the Solar Lamp. Carry in hand. Shows how much light is left. Table light.

INSTALLATION GUIDE MANUAL DE INSTALAÇÃO MANUAL DE INSTALACIÓN

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education

Manual Instructions for SAP Note Version 1

Mitos Desfeitos sobre Prevenção a Perda de Dados

HOJA DE REPARACIONES / FOLHA DE REPARO / REPAIR SHEET ESMERIL ANGULAR / ESMERILHADEIRA ANGULAR / ANGLE GRINDER USGACCHI / UNGACCHI

User's Guide. Manual de Utilizador

1. Product Name. 2. Product Code. 3. Colour. 4. Brief Description. 5. Contents. 6. Snoezelen Stimulations. Fibre Optic UFO

Regulador Integrado TA Rev.0. Regulador Integrado TA-956 Integrated Regulator TA-956

Cambridge International Examinations Cambridge International Advanced Subsidiary Level

Motors Automation Energy Transmission & Distribution Coatings. USB Plug-in Module Módulo Plug-in USB

ILLUMINATED VIBRATING BALLPOOL 19273

Radio / CD. Honolulu CD50. Installation instructions Notice de montage Instrucciones de instalación Instruções de de montagem

Miniature Solenoid Valve Type 200

Desumidificador de ar

ATLAS DE ACUPUNTURA VETERINáRIA. CãES E GATOS (EM PORTUGUESE DO BRASIL) BY CHOO HYUNG KIM

COMITÊ DO ESPECTRO PARA RADIODIFUSÃO - CER SPECTRUM DAY A REVISÃO DA REGULAMENTAÇÃO DO USO DA FAIXA DE 3,5 GHZ UMA NECESSIDADE COMPROVADA.

Writing Good Software Engineering Research Papers

IN RE: GUARDIAN ADVOCATE OF/ REF: CURATELA ESPECIAL DE

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education PORTUGUESE 0540/03

User s Manual ENGLISH. Manual del Usuario ESPAÑOL. Manual do Usuário PORTUGUES

Automação. Indústria smart. Indústria smart. Lucas Nülle GmbH Página 1/5

Programa de Educação Continuada em Angiografia

Futebol em Transmissão. Football is on the Air.

Dr. Leonardo Addêo Ramos CRM: Especialista em Medicina Esportiva e Ortopedia e Traumatologia do Esporte Doutorado em Ortopedia pela UNIFESP

75, 8.º DTO LISBOA

Tip: If you want a smaller bead, trim a couple inches off the length of the foil. Experiment until you get the perfect size!

Artroscopia. Artroscopia Arthroscopy

PROGRAM FOR 3 DAYS in Faial and S. Jorge Islands, Azores

Guia de Instalação Rápida TBW-101UB TBW-102UB

Transcrição:

Percutaneous Leads CAUTION: Federal law restricts this device to sale, distribution and use by or on the order of a physician. Directions for Use SC-2016-xx Infinion 16 Lead and Splitter 2x8 Kit SC-2016-xxE Infinion 16 Lead and Splitter 2x8 Trial Kit SC-2138-xx Linear xxcm 8 Contact Lead SC-2158-xx Linear xxcm 8 Contact Lead SC-2158-xxE Linear xxcm 8 Contact Lead SC-2208-xx Linear ST xxcm 8 Contact Lead SC-2218-xx Linear ST xxcm 8 Contact Lead SC-2218-xxE Linear ST xxcm 8 Contact Lead SC-2352-xx Linear 3-4 xxcm 8 Contact Lead SC-2352-xxE Linear 3-4 xxcm 8 Contact Lead SC-2366-xx Linear 3-6 xxcm 8 Contact Lead SC-2366-xxE Linear 3-6 xxcm 8 Contact Lead SC-3138-xx xxcm 8 Contact Extension SC-3304-xx D4 Splitter 2x4 SC-3354-xx W4 Splitter 2x4 SC-2316-xx Infinion 16 xxcm 16 Contact Lead Kit SC-2316-xxE Infinion 16 xxcm 16 Contact Trial Lead Kit SC-3400-xx xxcm Splitter 2x8 Kit Note: xx = length (cm), xxe = length (cm) Trial Lead en es fr de it nl sv fi no da pt ptbr 90668144-03 REV A

Percutaneous Leads Directions for Use en Copyright 2012 Boston Scientific Corporation or its affiliates. All Rights Reserved. These documents are the property of Boston Scientific Corporation and shall not be reproduced, distributed, disclosed, or used for manufacture or sale of device without the express written consent of Boston Scientific Corporation. Guarantees Boston Scientific Corporation reserves the right to modify, without prior notice, information relating to its products in order to improve their reliability or operating capacity. Drawings are for illustration purposes only. Trademarks Precision, Precision Spectra, Linear, Bionic Navigator, and Infinion are trademarks of Boston Scientific. Other brands and their products are trademarks or registered trademarks of their respective holders and should be noted as such. Percutaneous Leads Directions for Use 90668144-03 Rev A 1 of 312

Table of Contents Table of Contents Description...4 Percutaneous Leads...4 Trial Leads...4 Lead Extension...5 Infinion Lead...5 Lead Splitters...5 en Package Contents...6 Percutaneous Permanent Lead Kits...6 Percutaneous Trial Lead Kit...6 Lead Extension Kit...6 2x4 Splitter Kit...6 Spliter 2x8 Kit...7 Infinion 16 Lead Kit...7 Infinion 16 Trial Lead Kit...7 Infinion 16 Trial Configuration Kit...7 Infinion 16 Configuration Kit...7 Specifications and Technical Data...8 Linear Lead...8 Infinion Lead...8 Lead Extension...9 2x4 Splitter...9 Splitter 2x8...9 Registering the Leads...10 Instructions for Use... 11 Lead, Lead Extension, and Splitter Handling and Storage... 11 Percutaneous Lead Placement in the Epidural Space... 11 Lead Connection to Splitter...13 Intraoperative Stimulation Testing...15 Securing the Trial Lead...17 Permanent Lead Anchoring and Tunneling...18 Tunneling the Lead or Lead Extension...20 Connecting the Lead Extension...22 Lead/Extension/Splitter Removal...23 Programming with the Infinion 16 Lead...25 Percutaneous Leads Directions for Use 90668144-03 Rev A 2 of 312

Percutaneous Leads Directions for Use en Refer to the Information for Prescribers manual that accompanied your Precision Spectra IPG Or Refer to the Precision Clinician Manual that accompanied your Precision IPG for the following information: Contraindications Warnings Precautions Adverse Events Physician Instructions Storage and Handling Sterilization Information on Contacting Boston Scientific : Clinical studies supporting the clinical use of the neurostimulation system. For Indications for Use: Refer to the Indications for Use that accompanied your Precision Spectra IPG OR Refer to the Precision Clinician Manual that accompanied your Precision IPG. Refer to the Labeling Symbols Addendum for an explanation of labeling symbols. If you are using the Precision System, refer to the Precision Spinal Cord Stimulator System Clinician Manual and BionicNavigator Software Guide for device specific instructions not included in this manual. If you are using the Precision Spectra System, refer to the following Directions for Use (DFU) for device specific instructions not included in this manual: Precision Spectra System Implantable Pulse Generator DFU, Clinician Trial Manual, Surgical Leads DFU, Precision Spectra System Clinician Remote Control DFU, Precision Spectra System Spinal Cord Stimulation Programming Manual, and Programming Wand DFU. Refer to the Limited Warranty for warranty information. Percutaneous Leads Directions for Use 90668144-03 Rev A 3 of 312

Description Product Model Numbers Description SC-2016-xx Infinion 16 Lead and Splitter 2x8 Kit SC-2016-xxE Infinion 16 Lead and Splitter 2x8 Trial Kit SC-2138-xx Linear xxcm 8 Contact Lead SC-2158-xx Linear xxcm 8 Contact Lead SC-2158-xxE Linear xxcm 8 Contact Lead SC-2208-xx Linear ST xxcm 8 Contact Lead SC-2218-xx Linear ST xxcm 8 Contact Lead SC-2218-xxE Linear ST xxcm 8 Contact Lead SC-2352-xx Linear 3-4 xxcm 8 Contact Lead SC-2352-xxE Linear 3-4 xxcm 8 Contact Lead SC-2366-xx Linear 3-6 xxcm 8 Contact Lead SC-2366-xxE Linear 3-6 xxcm 8 Contact Lead SC-3138-xx xxcm 8 Contact Extension SC-3304-xx D4 Splitter 2x4 SC-3354-xx W4 Splitter 2x4 SC-2316-xx Infinion 16 xxcm 16 Contact Lead Kit SC-2316-xxE Infinion 16 xxcm 16 Contact Trial Lead Kit SC-3400-xx xxcm Splitter 2x8 Kit Note: xx = length (cm), xxe = length (cm) Trial Lead Leads function as a component of Boston Scientific s Precision and Precision Spectra Spinal Cord Stimulation (SCS) systems by delivering electrical stimulation to the nerve structures in the dorsal aspect of the spinal cord, resulting in an inhibition of pain sensation. en Percutaneous Leads The eight-contact percutaneous leads are available in lengths of 30 cm, 50 cm, and 70 cm. Each Linear lead has eight electrode contacts located near the distal end. Each contact is 3 mm in length and is spaced 1, 4 or 6 mm from the adjacent contact. Trial Leads The Trial Lead Kit, containing the Linear Lead and the associated components, is intended to be used for the temporary trial phase. Percutaneous Leads Directions for Use 90668144-03 Rev A 4 of 312

Percutaneous Leads Directions for Use en Lead Extension Lead Extensions are designed to connect the percutaneous leads to the Precision or Precision Spectra IPG for spinal cord stimulation. The extension may be added to a lead to externalize the lead for a trial procedure or to extend the lead when a permanent IPG is implanted. Lead extensions are available in lengths of 25 cm, 35 cm, and 55 cm. Each extension has eight electrode contacts located near the distal end. Each contact is 3mm in length and is spaced 1 mm from the adjacent contact. The extension can be connected to either the Trial Stimulator (via an OR Cable Assembly included in the leads kit) or directly to the IPG. Infinion Lead The Infinion 16 percutaneous lead is available in lengths of 50 cm and 70 cm. Each lead has 16 contacts located near the distal end. The Infinion lead can be connected directly to a 1x16 OR Cable when using the Precision Spectra Trial Stimulator. When connecting to an IPG or a 1x8 or 2x8 OR Cable, a single Infinion 16 lead must be inserted into a Splitter 2x8, which then connects to the IPG s 8 contact ports or the 1x8 or 2x8 OR Cable. Lead Splitters The 2x4 Lead Splitters are designed to connect multiple percutaneous leads to the Precision or Precision Spectra IPG. The Linear leads may be inserted into a splitter for a maximum of four Linear leads per Precision IPG and a maximum of eight leads per Precision Spectra IPG. Four of the eight contacts of each Linear lead will be activated. Two configurations of Splitter 2x4 are available: Distal 4 (D4) and Wide 4 (W4). The two versions offer different contact configurations. The Lead Splitter 2x8 is required to connect the Infinion 16 contact lead to the IPG. Each Infinion 1x16 lead requires a Splitter 2x8 to be used with two IPG ports. Percutaneous Leads Directions for Use 90668144-03 Rev A 5 of 312

Package Contents Package Contents Percutaneous Permanent Lead Kits (1) Percutaneous Lead with pre-loaded Curved Stylet (1) Stylet Ring with a Curved and a Straight Stylet (4) Suture Sleeves (1) Insertion Needle with Stylet (1) Lead Blank (1) Steering Cap (1) OR Cable Assembly (2) Lead Position Labels left and right (non-sterile) (1) Device Registration Form/Temporary Patient Identification Card (1) Manual en Percutaneous Trial Lead Kit (1) Percutaneous Lead with pre-loaded Curved Stylet (1) Suture Sleeve (1) Insertion Needle with Stylet (1) Steering Cap (1) OR Cable Assembly (2) Lead Position Labels left and right (non-sterile) (1) Device Registration Form/Temporary Patient Identification Card (1) Manual Lead Extension Kit (1) Lead Extension (1) Hex Wrench (1) Tunneling Tool Assembly (1) Device Registration Form/Temporary Patient Identification Card (1) Manual 2x4 Splitter Kit (1) Splitter (1) Hex wrench (1) Manual (1) Device Registration Form/Temporary Patient Identification Card Percutaneous Leads Directions for Use 90668144-03 Rev A 6 of 312

Percutaneous Leads Directions for Use en Spliter 2x8 Kit (1) Splitter 2x8 (1) Torque Wrench (1) Manual (1) Device Registration Form/Temporary Patient Identification Card Infinion 16 Lead Kit (1) 16 Contact Lead with pre-loaded Curved Stylet (1) Stylet Ring with a Curved and a Straight Stylet (1) Straight Stylet (4) Suture Sleeves (1) Insertion Needle (1) Lead blank (1) Steering Cap (2) Lead Position Labels left and right (non-sterile) (1) Device Registration Form/Temporary Patient Identification Card (1) Manual Infinion 16 Trial Lead Kit (1) 16 Contact Percutaneous Lead with pre-loaded Curved Stylet (1) Suture Sleeve (1) Insertion Needle (1) Steering Cap (2) Lead Position Labels left and right (non-sterile) (1) Device Registration Form/Temporary Patient identification Card (1) Manual Infinion 16 Trial Configuration Kit (1) Infinion 16 Trial Lead Kit (1) 2x8 Splitter Kit Infinion 16 Configuration Kit (1) Infinion 16 Lead Kit (1) 2x8 Splitter Kit Percutaneous Leads Directions for Use 90668144-03 Rev A 7 of 312

Specifications and Technical Data Specifications and Technical Data Linear Lead Part Specifications Lead Lengths 30, 50, 70 cm Lead shape In-line Lead Diameter 1.3 mm Number of Electrode Contacts 8 Electrode Length 3 mm Electrode Spacing 1, 4, or 6 mm Contact Material Platinum/Iridium Insulation Material Polyurethane Conductor Material MP35N-DFT-28% Ag en Infinion Lead Part Specifications Lead Lengths 50, 70 cm Lead shape In-line Lead Diameter 1.3 mm Number of Contacts 16 Contact Length 3 mm Contact Spacing 1 mm Contact Material Platinum/Iridium Insulation Material Polyurethane Conductor Material 35N LT-DFT-28% Ag Percutaneous Leads Directions for Use 90668144-03 Rev A 8 of 312

Percutaneous Leads Directions for Use en Lead Extension Part Specifications Extension Lengths 25, 35, 55 cm Extension Diameter 1.3 mm Number of Electrode Contacts 8 Contact Material Platinum/Iridium, Stainless Steel Insulation Material Silicone, Polyurethane Conductor Material MP35N-DFT-28% Ag 2x4 Splitter Part Splitter Length Splitter Diameter Number of Electrode Contacts Contact Material Insulation Material Conductor Material Specifications 25 cm 1.3 mm (each segment) 8 (4 per receptacle) Platinum/Iridium, Stainless Steel Silicone, Polyurethane MP35N-DFT-28% Ag Splitter 2x8 Part Splitter Length Splitter Diameter Number of Electrode Contacts Contact Material Insulation Material Conductor Material Specifications 30 cm 1.3 mm (each segment) 16 (8 per tail) Platinum/Iridium, Stainless Steel Silicone, Polyurethane MP35N-DFT-28% Ag Percutaneous Leads Directions for Use 90668144-03 Rev A 9 of 312

Registering the Leads Registering the Leads In accordance with international practice and regulatory legislation in some countries, a registration form is packed with each Boston Scientific lead/lead extension/splitter. The purpose of this form is to maintain traceability of all products and to secure warranty rights. It also allows the institution involved in the evaluation or replacement of a specific implanted lead, accessory or device to gain quick access to pertinent data from the manufacturer. Fill out the registration form included in the package contents. Return one copy to Boston Scientific, keep one copy for patient records, provide one copy to the patient, and one copy to the physician. Boston Scientific Neuromodulation 25129 Rye Canyon Loop Valencia, California 91355, USA Attention: Customer Service Department en Percutaneous Leads Directions for Use 90668144-03 Rev A 10 of 312

Percutaneous Leads Directions for Use en Instructions for Use Physician training is required. Boston Scientific also recommends that implanting physicians read all product labeling prior to using our devices. Lead, Lead Extension, and Splitter Handling and Storage Avoid damaging the lead with sharp instruments or excessive force during surgery. Do not sharply bend or kink the lead, extension, or splitter. Do not tie suture(s) directly to the lead, extension, or splitter body; use the provided suture sleeves. For the Percutaneous Leads avoid forcing the lead into the epidural space by carefully clearing a path using the lead blank. Avoid pulling an implanted lead taut; provide a stress relief loop at the insertion site to minimize tension on the lead. Avoid handling the lead with sharp instruments; use only rubber-tipped forceps. Take care when using sharp instruments such as hemostats or scalpels to prevent damaging the lead. Wipe off any body fluids from the lead connector end before connecting it to any other component. Fluid contamination of these connections could compromise the integrity of the stimulation circuit. Wipe off any body fluids from the lead stylet before inserting or reinserting it into the lead. Store components between 0 C and 45 C (32 F and 113 F) in an area where they are not exposed to liquids or excessive moisture. Temperatures outside of the stated range can cause damage. Percutaneous Lead Placement in the Epidural Space 1. Position, prep and drape the patient in the usual accepted manner. Inject a local anesthetic at the needle insertion site. 2. Under fluoroscopic guidance, place the insertion needle into the epidural space with the bevel facing up using an angle of 45 or less. Percutaneous Leads Directions for Use 90668144-03 Rev A 11 of 312

Instructions for Use en CAUTION: Use only an insertion needle provided by Boston Scientific. Other needles may damage the lead. The stamped number 14 on the needle hub (or the triangle on the hub of the curved Epimed needle, sold separately) corresponds to the orientation of the bevel, which must face up. Turning the bevel ventral (down) may result in lead damage. An angle of more than 45 increases the risk of lead damage. WARNING: The angle of the insertion needle should be 45 or less. Steep angles increase the insertion force of the stylet and also present more of an opportunity for the stylet to pierce the lead and cause tissue damage. 3. Remove the needle stylet from the insertion needle and verify entry into the epidural space using the standard technique. 4. OPTIONAL. Under fluoroscopic guidance, insert the lead blank through the insertion needle and into the epidural space. Advance the lead blank to verify entry into the epidural space, then withdraw the blank. 5. While holding the lead stylet handle, place the steering cap over the proximal end of the stylet handle with moderate force until it is held in place. Then slowly insert the lead, with stylet, through the insertion needle. The lead stylet should extend to the tip of the lead. 6. OPTIONAL. If exchange of the lead stylet is desired, carefully pull out the existing stylet and insert the preferred stylet. While inserting the stylet into the lead, if resistance is encountered, withdraw the stylet approximately 3 cm, rotate the lead and/or stylet, and gently advance the stylet. If resistance is still encountered, repeat the above procedure until the stylet can be fully inserted. WARNING: Do not exchange the lead stylet while the electrode array of the lead is in the bevel of the insertion needle. If the electrode array is in the bevel area, remove the lead from the insertion needle before exchanging the stylet. Inserting the lead stylet in the lead while the electrode array is in the bevel of the insertion needle increases the risk of lead and tissue damage. Percutaneous Leads Directions for Use 90668144-03 Rev A 12 of 312

Percutaneous Leads Directions for Use en WARNING: If the lead stylet is removed and reinserted, do not use excessive force when inserting the stylet into the lead. The use of instruments, such as forceps, to grasp the stylet during insertion is not recommended as this could result in applying excessive force and could increase the risk of lead and tissue damage. 7. Advance the lead to the appropriate vertebral level under fluoroscopic guidance. A sufficient length of lead (for example, at least 10 cm, or approximately three vertebrae) should reside in the epidural space to aid in lead stabilization. 8. If using a splitter, proceed to Lead Connection to Splitter in this manual. OR If not using a splitter, proceed to the instructions for connecting to the OR Cable assembly: If using the Precision System, refer to Connecting the OR Cable Assembly in the Precision Spinal Cord Stimulator System Clinician Manual. If using the Precision Spectra System, refer to Insert the Leads into the OR Cable Connector in the Clinician Trial Manual for the Precision Spectra System. Lead Connection to Splitter 1. Carefully withdraw the stylets from the leads to be inserted into the splitter. 2. Wipe clean the proximal connector ends of the leads. 3. Select the desired splitter model. Note: A Splitter 2x8 must be used when implanting the Infinion 16 lead. 4. Check that the lead connector end can be easily inserted into the splitter without obstruction. If obstruction is encountered, loosen the set screws of the splitter by using the hex wrench provided, turning counterclockwise. Note: The set screw should only be loosened to an amount sufficient to insert a lead. Do not excessively loosen the set screw. This may cause the set screw to dislodge rendering the splitter unusable. Percutaneous Leads Directions for Use 90668144-03 Rev A 13 of 312

Instructions for Use 5. Insert proximal connector ends of desired leads into splitter receptacles until they are fully seated - each lead bottoms out in receptacles and retention sleeves (long ring) are under the set screw blocks of the splitter receptacles. Do not tighten set screw at this time. 6. If using the Precision System, proceed to Connecting to the OR Cable Assembly in the Precision Spinal Cord Stimulator System Clinician Manual. OR If using the Precision Spectra System, proceed to Insert the Leads into the OR Cable Connector in the Clinician Trial Manual for the Precision Spectra System. 7. Check connections with an impedance measurement. If the impedance is satisfactory proceed to Intraoperative Stimulation Testing on page 15 to confirm proper lead location. Note: Do not tighten set screw mechanical lock before intraoperative stimulation testing, Note: On the 2x4 Splitter, the shorter splitter receptacle corresponds to contacts 1-4, while the longer receptacle corresponds to contacts 5-8. Make note of which lead is connected to each splitter receptacle. Note: On the Splitter 2x8, one tail is laser-marked with bands, and corresponds to contacts 1-8 on the 16 contact percutaneous leads; the unmarked tail corresponds to contacts 9-16. en Percutaneous Leads Directions for Use 90668144-03 Rev A 14 of 312

Percutaneous Leads Directions for Use en 8. If lead repositioning is required, disconnect the splitter and reinsert the stylet before advancing the lead. Repeat steps 5 to 7 until satisfactory lead position is achieved. 9. Use the hex wrench supplied to tighten down the setscrews until the wrench clicks. Medical Adhesive 10. If using the Splitter 2x8, prior to closing the wound, clean the top of the splitter set-screw seal plug and use silicone medical adhesive (e.g. Dow Corning Silastic Medical Adhesive Silicone, Type A - Sterile, as available from Boston Scientific, part number SC-4320) to coat and seal the top of the seal plug that has been penetrated by the hex wrench. Note: Inadvertent damage to the septum seal may lead to unintended stimulation at the Splitter 2x8 if the Medical Adhesive is not used as intended. 11. For Intraoperative Testing proceed to the instructions for Connecting to the Trial Stimulator: OR If using the Precision System, refer to Connecting to the Trial Stimulator in the Precision Spinal Cord Stimulator System Clinician Manual. If using the Precision Spectra System, refer to Insert the Leads into the OR Cable Connector in the Clinician Trial Manual for the Precision Spectra System. To connect to an IPG, refer to the directions as follows: If using the Precision System, refer to Connecting to the IPG in the Precision Spinal Cord Stimulator System Clinician Manual. If using the Precision Spectra System, refer to Connecting the Lead, Extension, Splitter, or Connector to the IPG in the Precision Spectra System IPG DFU. Intraoperative Stimulation Testing Note: The following steps are for procedural reference only. For detailed stimulation testing procedures and guidelines refer to the appropriate programming manual: If using the Precision System, refer to the BionicNavigator Software Guide. If using the Precision Spectra System, refer to the Precision Spectra System Programming Manual. Percutaneous Leads Directions for Use 90668144-03 Rev A 15 of 312

Instructions for Use 1. If using a splitter Visually check splitter to leads connection Check impedance Note: If using the 2x4 Splitter, make note of splitter configuration in the Programming software: If using the Precision System, refer to the Splitter Programming Guide for BionicNaviator software. If using the Precision Spectra System, refer to the Precision Spectra System Programming Manual. 2. After linking the Clinician Programmer to the Trial Stimulator, check impedances to verify that components are properly connected. Lead impedance is measured and displayed for each of the IPG s contacts: For the Precision System, impedance is measured and displayed for each of the IPG s 16 contacts. Impedances are displayed with an x on the BionicNavigator software. For the Precision Spectra System impedance is measured and displayed for each of the IPG s 32 contacts. Refer to Precision Spectra System Programming Manual for additional information on how impedances are displayed on the Precision Spectra System Clinician Programmer software. Impedances, indicated by an x on your Bionic Navigator software or indicated by an orange circle on the Precision Spectra System Clinician Programmer software are considered to be resultant from open or unconnected wires. 3. Using test stimulation, enlist patient feedback to verify lead placement and pain coverage. Note: If lead repositioning is necessary, turn stimulation off before proceeding. 4. Reposition leads as necessary. If using a splitter, gently pull on lead attached to splitter to reposition caudad or disconnect splitter from leads, re-insert stylet, and advance leads to reposition cephalad. en CAUTION: Do not force stylet into lead. 5. Steer lead to new position. 6. Remove stylet, wipe proximal ends of leads, and reconnect splitter. 7. Check impedances. 8. Repeat steps 1-3 if lead has been repositioned. Percutaneous Leads Directions for Use 90668144-03 Rev A 16 of 312

Percutaneous Leads Directions for Use en 9. When the desired paresthesia is achieved: a) Turn the Trial Stimulator off. b) Unlock each OR cable connector and disconnect from the lead(s). c) For percutaneous lead(s) - Slowly withdraw the stylet(s). 10. Record the lead position by capturing a fluoroscopic image to be sure the leads have not moved. Retest if necessary. 11. If using a splitter disconnect splitter from leads. Insert the hex wrench and turn the set screw counter clockwise to loosen. Note: The set screw should only be loosened to an amount sufficient to insert a lead. Do not excessively loosen the set screw. This may cause the set screw to dislodge, rendering the splitter unusable. Option A: For a Temporary Trial, proceed to Securing the Trial Lead on page 17. Option B: For a Permanent Trial, proceed to Permanent Lead Anchoring and Tunneling on page 18. Option C: For a Permanent IPG Implantation using percutaneous leads, proceed to Permanent Lead Anchoring and Tunneling on page 18. Option D: For a Permanent IPG Implantation using paddle leads, proceed to Permanent Lead Anchoring and Tunneling in the Surgical Leads DFU. Before receiving a permanent SCS system, it is recommended that patients undergo a trial procedure so that they can experience stimulation to evaluate if SCS is effective at treating their chronic pain. Securing the Trial Lead 1. Carefully withdraw the insertion needle from the epidural space by slowly pulling the needle up towards the proximal end of the lead while holding the lead in place. 2. Once the insertion needle tip is exposed, hold the lead as close to the percutaneous exit site as possible, then carefully pull the needle completely from the lead. Percutaneous Leads Directions for Use 90668144-03 Rev A 17 of 312

Instructions for Use 3. If desired, a suture may be used to close the wound and stabilize the lead. 4. Place and tape a stress relief loop and dress the wound. 5. If using a splitter, refer to Lead Connection to Splitter on page 13. 6. For temporary lead trials, refer to Connecting to the Trial Stimulator in the Precision Spinal Cord Stimulator System Clinician Manual for instructions on connecting to the OR Cable assembly, or to Insert the Leads into the OR Cable Connector in the Clinician Trial Manual for the Precision Spectra System. en Permanent Lead Anchoring and Tunneling Removing the Insertion Needle 1. Cut down around the insertion needle to provide access for anchoring the lead. 2. Carefully withdraw the insertion needle from the epidural space by slowly pulling the needle up towards the proximal end of the lead while holding the lead in place. 3. Once the insertion needle tip is exposed, hold the lead as close to the exit site as possible, then carefully pull the needle completely from the lead. Anchoring the Lead Leads can be permanently anchored with a suture sleeve or with a Clik Anchor. Refer to the Clik Anchor Directions for Use, or continue with the following steps to anchor using a suture sleeve. 1. For percutaneous leads, carefully remove the lead stylet using fluoroscopy to ensure the lead position does not change. 2. Place a suture sleeve over the lead and down to the supraspinous ligament or deep fascial tissue. 3. Ligate the suture sleeve onto the lead by tying a 2-0 silk or other nonabsorbable suture around the center groove of the sleeve to prevent sliding. Circumferential stitches may be tied at the compression slots. Percutaneous Leads Directions for Use 90668144-03 Rev A 18 of 312

Percutaneous Leads Directions for Use en CAUTION: Do not use polypropylene sutures as they may damage the suture sleeve. Do not suture directly onto the lead, splitter, or use a hemostat on the lead body. This may damage the lead insulation. Note: The 4 cm and 2.3 cm Suture Sleeves each have three (3) compression slots, which are designed to reduce slippage. 4. Suture the sleeve to the supraspinous ligament or deep fascia through the suture sleeve holes. 5. Tie multiple sutures as tightly as possible around the suture sleeve to secure it to the lead. CAUTION: Tightening sutures directly on the lead can damage the lead. 6. For Permanent Trials, proceed to Tunneling the Lead or Lead Extension on page 20. 7. For permanent IPG implantation: If using the Precision System, refer to IPG Implantation in the Precision Spinal Cord Stimulator Clinician Manual. If using the Precision Spectra System, refer to IPG Implantation in the Precision Spectra System Implantable Pulse Generator DFU. Percutaneous Leads Directions for Use 90668144-03 Rev A 19 of 312

Instructions for Use Tunneling the Lead or Lead Extension 1. Attach the tunneling tool handle to the shaft by turning the locking mechanism clockwise. Tool Handle en Locking Mechanism Shaft 2. Mark the desired route of the tunnel. 3. Administer the appropriate local anesthetic along the tunneling path. 4. OPTIONAL. If necessary, bend the tool shaft to conform to the patient s body. 5. Make a small incision at the desired exit site. 6. Create a subcutaneous tunnel between the midline incision and the exit site until the straw is visible and accessible at the exit point. Percutaneous Leads Directions for Use 90668144-03 Rev A 20 of 312

Percutaneous Leads Directions for Use en 7. Unscrew and remove the tunneling tool handle. 8. Grasp the tip of the tool with one hand while holding the straw in place with the other hand. Pull the tunneling tool shaft out through the straw. 9. Push the lead or extension proximal ends through the straw, then withdraw the straw. CAUTION: Do not tunnel splitter. Note: If using the 2x8 Splitter and performing a permanent trial, the splitter tails may be tunneled to the exit site. 10. For Permanent Trials: If using the Infinion 1x16 lead, proceed to Lead Connection to Splitter on page 13. Otherwise, proceed to Connecting the Lead Extension on page 22. 11. For Permanent IPG Implantation, if extensions are used, proceed to the instructions for Connecting the Lead Extension on page 22. 12. For Permanent IPG Implantation, if splitters are used, proceed to the instructions for Lead Connection to Splitter on page 13. 13. For Permanent IPG Implantation: If using the Precision System, refer to Connecting to the IPG in the Precision Spinal Cord Stimulator System Clinician Manual. Percutaneous Leads Directions for Use 90668144-03 Rev A 21 of 312

Instructions for Use If using the Precision Spectra System, refer to Connecting the Lead, Extension, Splitter, or Connector to the IPG in the Precision Spectra System IPG DFU. Note: The following Codman Disposable Catheter Passers may be used in place of the Boston Scientific tunneling tool: REF 82-1515 (36 cm); REF 82-1516 (55 cm); REF 82-1517 (65 cm) Note: When using a Codman Disposable Catheter Passer, tunnel from the IPG pocket to the midline incision using the standard technique. en Connecting the Lead Extension 1. Wipe clean the proximal end of the lead, then insert the proximal end into the lead extension connector or splitter until it stops and the retention ring (long ring) is under the setscrew. Note: If there appears to be an obstruction when inserting the lead into the lead extension connector, use the hex wrench to loosen (counterclockwise) the setscrew and/or gently rotate the lead to help advance the proximal end. 2. Ensure that the lead is fully inserted before tightening the set screw to prevent lead damage. 3. Using the hex wrench supplied, turn the extension connector setscrew clockwise until it clicks, indicating lock. Note: Ensure that the hex wrench is fully seated in the setscrew before tightening. Note: The hex wrench is torque-limited and cannot be overtightened. 4. Form an appropriately-sized pocket using blunt dissection on either side of midline for coiled excess lead and extension connectors. 5. Place a small loop at the lead for slack. If necessary, loosely tie a suture around the leadloop, but do not tighten onto the lead. CAUTION: Tightening sutures directly on the lead can damage the lead. Percutaneous Leads Directions for Use 90668144-03 Rev A 22 of 312

Percutaneous Leads Directions for Use en 6. Carefully remove excess slack by gently pulling the extensions from the exit wound. 7. For Permanent Trials, if desired, a small suture may be used to close the exit wound of the extension. Place and tape a stress relief loop and dress the wound. Proceed to the instructions for Connecting to the Trial Stimulator in the Precision Spinal Cord Stimulator System Clinician Manual or to Insert the Leads into the OR Cable Connector in the Clinician Trial Manual for the Precision Spectra System. 8. For Permanent Implant, close the midline incision, and proceed as follows: If using the Precision System, refer to Connecting the IPG in the Precision Spinal Cord Stimulator System Clinician Manual. If using the Precision Spectra System, refer to Connecting the Lead, Extension, Splitter, or Connector to the IPG in the Precision Spectra System Implantable Pulse Generator DFU. Lead/Extension/Splitter Removal Remove bandages and properly cleanse the exit site. The method of removal depends upon whether a temporary trial or permanent trial was performed. Option A: Percutaneous Lead Removal after Temporary Trial 1. Clip sutures if used to secure the trial lead(s) in place. 2. Remove the lead(s) and discard. Percutaneous Leads Directions for Use 90668144-03 Rev A 23 of 312

Instructions for Use en 3. To replace the trial lead(s) with permanent percutaneous lead(s), proceed to the instructions for Percutaneous Lead Placement in the Epidural Space on page 11. 4. To replace the trial lead(s) with a paddle lead proceed to instructions for Surgical Paddle Lead Placement in the Epidural Space in the Surgical Leads DFU. Option B: Lead Extension Removal After Permanent Trial 1. Open the midline incision to expose the lead extension and connector. 2. Cut the lead extension at the connector. Do not cut the implanted lead. 3. Remove the extension, being careful not to contact non-sterile portions to the patient s body. 4. Loosen the extension connector setscrew using the hex wrench. Disconnect and remove the connector without moving the implanted lead. 5. Proceed to the IPG Implantation instructions as follows: If using the Precision System, refer to IPG Implantation in the Precision Spinal Cord Stimulator System Clinician Manual. If using the Precision Spectra System, refer to IPG Implantation in the Precision Spectra System Implantable Pulse Generator DFU. Option C: Splitter Removal 1. If the splitter has been implanted, open the incision to expose the lead and splitter junction. 2. Loosen the connector set screw on the splitter receptacles using the hex wrench provided. 3. Disconnect and discard the splitter components. Percutaneous Leads Directions for Use 90668144-03 Rev A 24 of 312

Percutaneous Leads Directions for Use en Programming with the Infinion 16 Lead For detailed programming instructions, refer to the appropriate BionicNAVIGATOR Software Guide or the Precision Spectra System Programming Manual. If using the Precision Spectra System Clinician Programmer software: When the Infinion 16 lead is used with the Splitter 2x8 and placed properly into the Precision Spectra IPG ports (the splitter tail with laser etched bands to the left ports A or C and the unmarked splitter tail to the right ports B or D) the laser marked splitter tail corresponds to contacts 1-8 on the distal end of the Infinion lead and the unmarked splitter tail corresponds to contacts 9-16 of the Infinion Lead. If using Bionic Navigator Software: When the Infinion 16 lead is used with the Splitter 2x8 and placed properly into the Precision IPG ports (laser-marked tail of Splitter 2x8 connecting to IPG port 1-L ), the distal 8 contacts of the Infinion 16 lead (contacts 1-8) will correspond with contacts 1-8 on the left side of the BionicNavigator software display. Likewise, the proximal 8 contacts of the Infinion 16 lead (contacts 9-16) will correspond with contact 9-16 on the right side of the BionicNavigator software display. The diagram below depicts this wiring. Using test stimulation, enlist patient feedback to verify lead placement and pain coverage. The user may program with the Infinion 16 lead using all the functions available in BionicNavigator for the Linear family of leads (E-Troll, Navigator, etc.). For complete instructions on programming, see the BionicNavigator Software Guide. Percutaneous Leads Directions for Use 90668144-03 Rev A 25 of 312

Programming with the Infinion 16 Lead en This page intentionally left blank. Percutaneous Leads Directions for Use 90668144-03 Rev A 26 of 312

Instrucciones de uso para electrodos percutáneos es Copyright 2012 Boston Scientific Corporation o sus empresas afiliadas. Reservados todos los derechos. La presente documentación es propiedad de Boston Scientific Corporation y no está permitida su reproducción, distribución, exposición o uso para la fabricación o venta de dispositivo alguno sin el consentimiento expreso y por escrito de Boston Scientific Corporation. Garantías Boston Scientific Corporation se reserva el derecho de modificar, sin aviso previo, la información relativa a estos productos con el objetivo de mejorar su fiabilidad o capacidad operativa. Las imágenes son meramente ilustrativas. Marcas comerciales Precision, Precision Spectra, Linear, Bionic Navigator e Infinion son marcas comerciales de Boston Scientific. Las demás marcas y sus productos son marcas comerciales o marcas registradas de sus respectivos titulares y deben citarse como tales. Instrucciones de uso para electrodos percutáneos 90668144-03 Rev A 27 de 312

Índice Índice Descripción...30 Electrodos percutáneos...30 Electrodos de prueba...30 Extensión del electrodo...31 Electrodo Infinion...31 Extensiones bifurcadas para electrodos...31 es Contenidos del paquete...32 Kits de electrodos permanentes percutáneos...32 Kit de electrodos de prueba percutáneos...32 Kit de extensión del electrodo...32 Kit de extensiones bifurcadas 2 x 4...32 Kit de extensión bifurcada 2 x 8...33 Kit de electrodos Infinion 16...33 Kit de electrodos de prueba Infinion 16...33 Kit de configuración de prueba Infinion 16...33 Kit de configuración de Infinion 16...33 Especificaciones y datos técnicos...34 Electrodo Linear...34 Electrodo Infinion...34 Extensión del electrodo...35 Extensión bifurcada 2 x 4...35 Extensión bifurcada 2 x 8...35 Registro de los electrodos...36 Instrucciones de uso...37 Manipulación y almacenamiento de los electrodos, extensiones del electrodo y extensiones bifurcadas...37 Colocación del electrodo percutáneo en el espacio epidural...37 Conexión de electrodos a la extensión bifurcada...39 Pruebas de estimulación intraoperatorias...41 Fijación del electrodo de prueba...43 Fijación permanente de los electrodos y tunelización...44 Tunelización del electrodo o extensión del electrodo...46 Conexión de la extensión del electrodo...48 Extracción del electrodo/extensión/extensión bifurcada...49 Programación con el electrodo Infinion 16...51 Instrucciones de uso para electrodos percutáneos 90668144-03 Rev A 28 de 312

Instrucciones de uso para electrodos percutáneos es Consulte el manual de Información para médicos que se incluye en el GII del sistema Precision Spectra o bien Consulte el Manual del médico del sistema Precision que se incluye en el GII del sistema Precision para obtener la información siguiente: Contraindicaciones Advertencias Precauciones Efectos adversos Instrucciones para médicos Almacenamiento y manipulación Esterilización Información de contacto de Boston Scientific : Estudios clínicos que respaldan el uso clínico del sistema de neuroestimulación. Indicaciones de uso: Consulte las Indicaciones de uso que se incluyen en el GII del sistema Precision Spectra o bien Consulte el Manual del médico del sistema Precision que se incluye en el GII del sistema Precision. Para obtener una explicación de los símbolos de etiquetado, consulte el Anexo de símbolos de etiquetado. Si usa el sistema Precision, consulte el Manual del médico del sistema de estimulación de la médula espinal Precision y la Guía del software BionicNavigator para obtener instrucciones específicas no incluidas en este manual. Si utiliza el sistema Precision Spectra, consulte las siguientes Instrucciones de uso (IDU) para obtener instrucciones específicas del dispositivo no incluidas en este manual: Instrucciones de uso del generador de impulsos implantable del sistema Precision Spectra, Manual de prueba para el médico, Instrucciones de uso de los electrodos quirúrgicos, Instrucciones de uso del control remoto para el médico del sistema Precision Spectra, Manual de programación de la estimulación de la médula espinal del sistema Precision Spectra e Instrucciones de uso de la varilla de programación. Consulte la Garantía limitada para obtener más información. Instrucciones de uso para electrodos percutáneos 90668144-03 Rev A 29 de 312

Descripción Números de modelo del producto Kit de electrodo de 16 contactos y extensión bifurcada 2 x 8 Infinion 16 SC-2016-xx Kit de prueba del electrodo de 16 contactos y extensión bifurcada 2 x 8 Infinion 16 SC-2016-xx Electrodo de 8 contactos xxcm Linear SC-2138-xx Electrodo de 8 contactos xxcm Linear SC-2158-xx Electrodo de 8 contactos xxcm Linear SC-2158-xxE Electrodo de 8 polos xxcm Linear ST SC-2208-xx Electrodo de 8 polos xxcm Linear ST SC-2218-xx Electrodo de 8 contactos xxcm Linear ST SC-2218-xxE Electrodo de 8 contactos 3-4 xxcm Linear SC-2352-xx Electrodo de 8 contactos 3-4 xxcm Linear SC-2352-xxE Electrodo de 8 contactos 3-6 xxcm Linear SC-2366-xx Electrodo de 8 contactos 3-6 xxcm Linear SC-2366-xxE Extensión de 8 contactos xx xxcm SC-3138-xx Extensión bifurcada 2 x 4 D4 SC-3304-xx Extensión bifurcada 2 x 4 W4 SC-3354-xx Kit del electrodo de 16 contactos de 16 xxcm Infinion 16 SC-2316-xx Kit del electrodo de prueba de 16 contactos de 16 xxcm Infinion 16 SC-2316-xxE Kit de extensión bifurcada 2 x 8 de xxcm SC-3400-xx Nota: xx = longitud (cm), xxe = longitud (cm) del electrodo de prueba Descripción El electrodo actúa como componente de los sistemas de estimulación de la médula espinal (EME) Precision y Precision Spectra de Boston Scientific, mediante la estimulación eléctrica de las estructuras nerviosas en el plano dorsal de la médula espinal, lo que inhibe la sensación de dolor. es Electrodos percutáneos Los electrodos percutáneos de ocho contactos están disponibles en los formatos de 30 cm, 50 cm y 70 cm. Cada electrodo Linear presenta ocho polos de contacto junto al extremo distal. Cada contacto tiene 3 mm de longitud y se encuentra a 1 mm, 4 mm o 6 mm de distancia del contacto más próximo. Electrodos de prueba El kit de electrodos de prueba, que contiene el electrodo Linear y sus componentes asociados, está concebido para utilizarse en la fase de prueba temporal. Instrucciones de uso para electrodos percutáneos 90668144-03 Rev A 30 de 312

Instrucciones de uso para electrodos percutáneos es Extensión del electrodo Las extensiones para electrodos están diseñadas para conectar los electrodos planos y percutáneos al GII Precision o Precision Spectra para la estimulación de la médula espinal. Es posible agregar una extensión a un electrodo para externalizarlo durante el procedimiento de prueba o para extenderlo en el caso de un implante de un GII permanente. Las extensiones de electrodos están disponibles en longitudes de 25 cm, 35 cm y 55 cm. Cada extensión presenta ocho polos de contacto junto al extremo distal. Cada contacto tiene 3 mm de longitud y se encuentra a 1 mm de distancia del contacto más próximo. La extensión puede conectarse a un estimulador de prueba (a través de un conjunto de cables de estimulación intraoperatoria que se incluye en el kit de electrodos) o directamente al GII. Electrodo Infinion El electrodo percutáneo Infinion 16 está disponible en longitudes de 50 cm y 70 cm. Cada electrodo tiene 16 contactos situados cerca del extremo distal. El electrodo Infinion puede conectarse directamente a un cable de estimulación intraoperatoria 1 x 16 al usar el estimulador de prueba Precision Spectra. Si lo conecta a un GII o a un cable de estimulación intraoperatoria 1 x 8 o 2 x 8, deberá insertar un solo electrodo Infinion 16 en una extensión bifurcada 2 x 8, que a su vez se conectará a los 8 puertos de contactos del GII o al cable de estimulación intraoperatoria 1 x 8 o 2 x 8. Extensiones bifurcadas para electrodos Las extensiones bifurcadas para electrodos 2 x 4 están diseñadas para conectar varios electrodos percutáneos al GII Precision o Precision Spectra. Los electrodos Linear pueden insertarse en una extensión bifurcada con un máximo de cuatro electrodos Linear por cada GII Precision y un máximo de ocho electrodos por GII Precision Spectra. Se activarán cuatro de los ocho contactos de cada electrodo Linear. Están disponibles dos configuraciones de extensiones bifurcadas 2 x 4: polos distales 4 (D4) y polos alternos 4 (W4). Las dos versiones ofrecen diferentes configuraciones de los contactos. La extensión bifurcada de electrodos 2 x 8 es necesaria para conectar el electrodo de 16 contactos Infinion al GII. Por cada electrodo Infinion 1 x 16, deberá utilizarse una extensión bifurcada 2 x 8 con dos puertos GII. Instrucciones de uso para electrodos percutáneos 90668144-03 Rev A 31 de 312

Contenidos del paquete Contenidos del paquete Kits de electrodos permanentes percutáneos (1) Electrodo percutáneo con estilete curvo precargado (1) Anillo de estilete con un estilete recto y uno curvo (4) Piezas de anclaje (1) Aguja de inserción con estilete (1) Pasador del electrodo (1) Accesorio para giro de estilete (1) Conjunto de cables de estimulación intraoperatoria (2) Etiquetas de colocación de los electrodos: izquierda y derecha (no estériles) (1) Formulario de registro del dispositivo/tarjeta temporal de identificación del paciente (1) Manual es Kit de electrodos de prueba percutáneos (1) Electrodo percutáneo con estilete curvo precargado (1) Piezas de anclaje (1) Aguja de inserción con estilete (1) Accesorio para giro de estilete (1) Conjunto de cables de estimulación intraoperatoria (2) Etiquetas de colocación de los electrodos: izquierda y derecha (no estériles) (1) Formulario de registro del dispositivo/tarjeta temporal de identificación del paciente (1) Manual Kit de extensión del electrodo (1) Extensión del electrodo (1) Llave hexagonal (1) Conjunto de tunelizadores (1) Formulario de registro del dispositivo/tarjeta temporal de identificación del paciente (1) Manual Kit de extensiones bifurcadas 2 x 4 (1) Extensión bifurcada (1) Llave hexagonal (1) Manual (1) Formulario de registro del dispositivo/tarjeta temporal de identificación del paciente Instrucciones de uso para electrodos percutáneos 90668144-03 Rev A 32 de 312

Instrucciones de uso para electrodos percutáneos es Kit de extensión bifurcada 2 x 8 (1) Extensión bifurcada 2 x 8 (1) Destornillador dinamométrico (1) Manual (1) Formulario de registro del dispositivo/tarjeta temporal de identificación del paciente Kit de electrodos Infinion 16 (1) Electrodo de 16 contactos con estilete curvo precargado (1) Anillo de estilete con un estilete recto y uno curvo (1) Estilete recto (4) Piezas de anclaje (1) Aguja de inserción (1) Pasador del electrodo (1) Accesorio para giro de estilete (2) Etiquetas de posición del electrodo: izquierda y derecha (no estériles) (1) Formulario de registro del dispositivo/tarjeta temporal de identificación del paciente (1) manual Kit de electrodos de prueba Infinion 16 (1) Electrodo percutáneo de 16 contactos con estilete curvo precargado (1) Pieza de anclaje (1) Aguja de inserción (1) Accesorio para giro de estilete (2) Etiquetas de posición del electrodo: izquierda y derecha (no estériles) (1) Formulario de registro del dispositivo/tarjeta temporal de identificación del paciente (1) Manual Kit de configuración de prueba Infinion 16 (1) Kit de electrodos de prueba Infinion 16 (1) Kit de extensión bifurcada 2 x 8 Kit de configuración de Infinion 16 (1) Kit de electrodos Infinion 16 (1) Kit de extensión bifurcada 2 x 8 Instrucciones de uso para electrodos percutáneos 90668144-03 Rev A 33 de 312

Especificaciones y datos técnicos Electrodo Linear Especificaciones y datos técnicos Pieza Especificaciones Longitudes de los electrodos 30 cm, 50 cm, 70 cm Forma del electrodo En línea Diámetro del electrodo 1,3 mm Número de contactos de los electrodos 8 Longitud del electrodo 3 mm Espacio entre electrodos 1 mm, 4 mm o 6 mm Material de contacto Platino/iridio Material de aislamiento Poliuretano Material conductor MP35N-DFT-28 % Ag es Electrodo Infinion Pieza Especificaciones Longitudes de los electrodos 50 cm, 70 cm Forma del electrodo En línea Diámetro del electrodo 1,3 mm Número de contactos 16 Longitud de los contactos 3 mm Espacio entre contactos 1 mm Material de contacto Platino/iridio Material de aislamiento Poliuretano Material conductor 35N LT-DFT-28 % Ag Instrucciones de uso para electrodos percutáneos 90668144-03 Rev A 34 de 312

Instrucciones de uso para electrodos percutáneos Extensión del electrodo es Pieza Especificaciones Longitudes de las extensiones 25 cm, 35 cm, 55 cm Diámetro de la extensión 1,3 mm Número de contactos de los electrodos 8 Material de contacto Platino/iridio, acero inoxidable Material de aislamiento Silicona, poliuretano Material conductor MP35N-DFT-28% Ag Extensión bifurcada 2 x 4 Pieza Longitud de la extensión bifurcada Diámetro de la extensión bifurcada Número de contactos de los electrodos Material de contacto Material de aislamiento Material conductor Especificaciones 25 cm 1,3 mm (cada segmento) 8 (4 en cada receptáculo) Platino/iridio, acero inoxidable Silicona, poliuretano MP35N-DFT-28% Ag Extensión bifurcada 2 x 8 Pieza Longitud de la extensión bifurcada Diámetro de la extensión bifurcada Número de contactos de los electrodos Material de contacto Material de aislamiento Material conductor Especificaciones 30 cm 1,3 mm (cada segmento) 16 (8 en cada extremo) Platino/iridio, acero inoxidable Silicona, poliuretano MP35N-DFT-28% Ag Instrucciones de uso para electrodos percutáneos 90668144-03 Rev A 35 de 312

Registro de los electrodos Registro de los electrodos De conformidad con las prácticas internacionales y la legislación vigente en algunos países, con cada electrodo/extensión del electrodo/extensión bifurcada de Boston Scientific se incluye un formulario de registro. La finalidad de este formulario es llevar un seguimiento de todos los productos y proteger los derechos de garantía. Asimismo, posibilita el acceso rápido a los datos pertinentes del fabricante por parte de la institución que interviene en la evaluación o sustitución de un determinado electrodo, accesorio o dispositivo implantado. Rellene el formulario de registro que se incluye en el envase. Envíe una copia a Boston Scientific, guarde otra con el expediente del paciente y proporcione también una copia al paciente y al médico. Boston Scientific Neuromodulation 25155 Rye Canyon Loop Valencia, California 91355, USA A la atención de: departamento del Servicio de atención al cliente es Instrucciones de uso para electrodos percutáneos 90668144-03 Rev A 36 de 312