Transmissor PROFIBUS PA / FOUNDATION Fieldbus. No. 5350V112-BR De ser. 090659001



Documentos relacionados
Transmissor programável 2 fios. No. 5334V108-BR De número de série:

Transmissor programável 2 fios. No. 5333V111-BR De número de serial:

Transmissor de nível 2 fios. No. 5343V105-BR De número de sérial:

2-Wire Programmable Transmitter. No. 5334V109-UK From ser. no

Transmissor Programável 2 fios. No.5331V113-BR De número de serial:

Transmissor PROFIBUS PA / FOUNDATION Fieldbus. No. 5350V113-BR De ser

Transmissor programável 2 fios. No.5331V115-BR De número de serial: CCOE

Transmissor programável 2 fios. No. 5333V112-BR De número de serial:

Instrução MI Janeiro de 2014

2-WIRE PROGRAMMABLE TRANSMITTER TT518

2-Wire Level Transmitter. No. 5343V105-UK From ser. no

Manual do produto 5350 Transmissor PROFIBUS PA / FOUNDATION Fieldbus

2-Wire Programmable Transmitter. No.5331V113-UK From ser. no

Transmissor de nível 2 fios. No. 5343V106-BR De número de sérial:

2-Wire Programmable Transmitter. No.5331V114-UK From ser. no CCOE

2-Wire Programmable Transmitter. No. 5333V112-UK From ser. no.:

Manual do produto 5331 Transmissor programável 2 fios

MANUAL DE INSTRUÇÕES E INSTALAÇÃO TERMINADOR FIELDBUS AGO / 12 BT302 B T M P FOUNDATION

CERTIFICADO de Conformidade Certificado número Certificate number

Manual do utilizador Edição 02/2007

CERTIFICADO DE CONFORMIDADE CERTIFICATE OF CONFORMITY

MI Junho lnstrução Ml Junho 2007 RTT15. Diagramas de Conexão de Segurança Intrínseca

CERTIFICADO de Conformidade Certificado número Certificate number

2-Wire Level Transmitter. No. 5343V104-UK From ser. no

CERTIFICADO de Conformidade Certificado número Certificate number

Analisador com interface FOUNDATION Fieldbus, medição de condutividade em áreas seguras e classificadas

Fábrica de Nordborg - Dinamarca

DEKRA X. PRelectronics A/S Lerbakken Rønde Dinamarca

INDICADOR DO NÍVEL DO RADAR INSTRUÇÕES ESPECIAIS DE SEGURANÇA

Transmissor de temperatura Fieldbus Para FOUNDATION Fieldbus e PROFIBUS PA Modelo T53.10, versão para cabeçote

CERTIFICADO DE CONFORMIDADE CERTIFICATE OF CONFORMITY

STD-T. Transmissor de Temperatura com Display LCD local

Os termômetros de resistência podem ser isolados de altas tensões. Todavia, na prática, o espaço de instalação disponível é frequentemente pequeno

CERTIFICADO DE CONFORMIDADE. N : 11-IEx-0015X

Informações adicionais para áreas potenciamente explosivas (Ex i) Modelo TR21

Transmissor de temperatura Fieldbus Modelo T53.10, para FOUNDATION Fieldbus e PROFIBUS PA

CERTIFICADO de Conformidade Certificado número Certificate number

Dados técnicos. necessário. Consumo de corrente Placa de medição não abrangida 3 ma Placa de medição abrangida

CONDICIONADORES DE SINAIS

Linha de Produtos Especificações Português. Portavo 904(X) COND. Últimas informações sobre o produto:

Fontes de Alimentação Repetidoras. IsoAmp PWR A 20100

CERTIFICADO DE CONFORMIDADE CERTIFICATE OF CONFORMITY

TRANSMISSOR INTELIGENTE DE TEMPERATURA TT301 TT301 TECNOLOGIA SMAR INTRODUÇÃO. Uma Família Completa de Instrumentos de Campo

Técnicas de Interfaceamento de Sinais em Áreas Classificadas. Alexandre M. Carneiro

Unidade de controle de alimentação. No. 9410V101-BR Versão do produto:

Instruções MI Julho de Conversor de sinais de corrente para Pneumático E69F e Posicionador eletropneumático E69P

Conversor ma / Temperatura. No. 9113V105-BR Versão do produto:

Série Regulador eletrônico de pressão diferencial

DAXXO RELÉ PARA CCM INTELIGENTE

Instruções de segurança VEGAFLEX FX61/62/65/66/67.CI****H**** VEGAFLEX FX63.CI***H**** AEX X

Megôhmetro Digital de 12kV

CERTIFICADO de Conformidade Certificado número Certificate number

Uni-Probe LB 490. Medição de Nível Sem Contato C O N T R O L E D E P R O C E S S O S

Caixa para transmissor de temperatura Modelo TIF11

CERTIFICADO de Conformidade Certificado número Certificate number

Manual de instruções. Botões de comando Série 44

Válvulas pneumáticas série 8000

ST90 / ST90A PT10. Transmissor e Sensor de Temperatura

Fontes de Alimentação

MANUAL DE INSTALAÇÃO D F 4 7 M P


Manual do Usuário. Transmissor de Temperatura YTA610 e YTA710 (Hardware) Revisão do Manual No

UMG 104-Mais do que um simples Multímetro UMG 104

Descrição do Produto. Dados para compra

DET NORSKE VERITAS CERTIFICADO DE CONFORMIDADE

CERTIFICADO de Conformidade

VariTrans A Duplicadores de sinais em alojamento de 6 mm com duas saídas calibradas chaveáveis, também para altas cargas na saída.

Cabeça de Rede de Campo PROFIBUS-DP

CAIXA DE CALIBRAÇÃO DE RELÉS DE PROTEÇÃO CE-6003

Transmissor de Pressão Capacitivo

Unidade de controle de alimentação. No. 9410V102-BR Versão do produto:

Instruções de segurança VEGADIF DF65.D******- Z/H/P/F*****

Dados técnicos. Dados gerais. Intervalo de comutação s n 4 mm

INTERFACE USB PARA PROFIBUS PA

Tradução do documento original. Uma nova versão do documento original está disponível. Série 3730 Posicionador Electropneumático Tipo

Druck UPS-III-IS. GE Sensing. Manual do usuário - KP0341. Calibrador de loop intrinsecamente seguro. Loop Calibrator. Druck UPS-III-IS.

VF2. Medidor de nível tipo radar de onda guiada (TDR) de 2 fios. Informações suplementares

Manual de Instalação, Operação e Manutenção. Chave Eletrônica de Nível LIDEC 91-92

CERTIFICADO de Conformidade Certificado número Certificate number

CERTIFICADO de Conformidade Certificado número Certificate number

LINHA COMPACTA. KOBO-pH transmissor de ph APM-Z

CONVERSOR DE FOUNDATION FIELDBUS PARA SINAL 4-20 ma B91. smar

Eberhardt Comércio e Assist. Técnica. Ltda.

Instruções de segurança VEGACAL CL6*.DI***HD***

Transcrição:

5350 Transmissor PROFIBUS PA / FOUNDATION Fieldbus No. 5350V-BR De ser. 09065900

BR A PR electronics oferece uma grande variedade de equipamentos condicionadores de sinais digitais e analógicos para automação industrial. A Variedade de produtos inclui Isoladores, Display, Interfaces Ex, Transmissores de Temperatura e Equipamentos Universais. Você pode confiar nossos produtos nos ambientes mais extremos com ruído elétrico, vibrações e oscilações de temperatura, e todos os produtos cumprem com os mais exigentes padrões do mercado.»signals the Best«é a personificação da nosso filosofia e sua garantia para qualidade. Todos os clientes poderão declarar uma reclamação através do telefone 0XX9-349-7890 ou email suporte@tsie.com.br ou pelo site: http://www.technosupply.com.br/blog/?page_id=03 543

TRANSMISSOR PROFIBUS PA / FOUNDATION FIELDBUS 5350 Conteúdo Aplicação... Características técnicas... Montagem / instalação... Aplicações... 3 Códigos para 5350... 4 Especificações elétricas... 4 Conexões de entrada... 8 Conexões de saída... 9 Especificações mecânicas... 9 Montagem dos cabos do sensor... 9 Diagrama de bloco... 0 Instalação de barramento... Apêndice... ATEX Installation Drawing - 5350B... 3 ATEX Installation Drawing - 5350A... 5 FM / CSA Installation Drawing... 6 NEPSI Installation Drawing... IECEx Installation Drawing... 4 INMETRO Instruções de Segurança... 6 5350V-BR

TRANSMISSOR PROFIBUS PA / FOUNDATION FIELDBUS - 5350 PROFIBUS PA ver. 3.0 FOUNDATION Fieldbus ver. ITK 4.6 Chave automática entre protocolos Certificado FISCO Capacidade básica com F.F. Aplicação Medição de temperatura linearizada com sensor RTD ou TC. Diferença média, ou redundância medição de temperatura com sensor RTD ou TC. Medição de resistência linear, potenciômetro e mv bipolar. Características técnicas Transmissor de barramento com ambos PROFIBUS PA e FOUNDATION Fieldbus comunicação.uma única chave de função garante a troca automática entre os dois protocolos. Configuração para PROFIBUS PA pode ser feita via Siemens Simatic PDM, ABB Melody / Software Harmony e Metso DNA e parta FOUNDATION Fieldbus via software Emerson DeltaV, Yokogawa CS 000 / CS 3000, ABB Melody / Harmony and Honeywell Experion. A função de modo de simulação pode ser ativada por meio de um imã. Polaridade independente do barramento de conexão. Conversor 4 bit A/D garante alta resolução. Blocos de função PROFIBUS PA: analógicos. Blocos de função Foundation Fieldbus: analógicos e PID. Capacidade FOUNDATION Fieldbus: Básica ou LAS. Montagem / instalação Para sensor tipo cabeçote B. Em áreas não perigosas o 5350 pode ser montado no trilho DIN com o suporte da PR 84. 5350V-BR

- + + - APLICAÇÕES RTD à barramento de comunicação ou TC à barramento de comunicação Resistência à barramento de comunicação mv à barramento de comunicação Diferença, média, ou redundância; RTD, TC ou mv - + - + - + + - 5350V-BR 3

Códigos para 5350 Tipo Versão 5350 Padrão, Área...: A ATEX, IECEx, FM, CSA, INMETRO & NEPSI...: B *NB! Por favor lembre-se de pedir à PR o conector tipo 84 se a função de modo de simulação é usado. Especificações elétricas Range de especificações: -40 C até +85 C Especificações comuns: Tensão de alimentação, DC Padrão... 9,0...3 V ATEX, IECEx, FM, CSA, INMETRO & NEPSI... 9,0...30 V Em instalações FISCO... 9,0...7,5 V Consumo... < ma Max. aumento de corrente em caso de erro... < 7 ma Tensão de isolação, teste...,5 kvac para 60 s Tensão de isolação, operação... 50 VRMS / 75 VDC Tempo de aquecimento... 30 s Sinal / relação de ruído... Min. 60 db Tempo de resposta (programável)......60 s Tempo de atualização... < 400 ms Tempo de execução, entrada analógica... < 50 ms Dinâmica de sinal, entrada... 4 bit Temperatura de calibração... 0...8 C Precisão, a maior para valores básicos e gerais: Valores gerais Tipo de entrada Precisão absoluta Coeficiente de temperatura Todos ±0,05% de leitura ±0,00% de leitura / C 5350V-BR 4

Valores básicos Tipo de entrada Precisão básica Coeficiente de temperatura Pt00 e Pt000 ±0, C ±0,00 C / C Ni00 ±0,5 C ±0,00 C / C Cu0 ±,3 C ±0,0 C / C Lin. R ±0,05 Ω ±0,00 Ω / C Volt ±0 µv ±0, µv / C Tipo TC: E, J, K, L, N, T, U ±0,5 C ±0,00 C / C Tipo TC: B, R, S, W3, W5 ± C ±0,05 C / C Influência de imunidade EMC... < ±0,% da leitura Imunidade EMC extendida: NAMUR NE, critério A, explosão... < ±% da leitura Vibração (DIN classe B)... IEC 60068--6 : 007...5 Hz... ±,6 mm 5...00 Hz... ±4 g Umidade... < 95% RH (sem cond.) Dimensões... Ø 44 x 0, mm Grau de proteção (capa / terminal)... IP68 / IP00 Peso... 55 g Especificações elétricas, entradas: Entrada RTD e resistência linear: Tipo RTD Pt5...Pt000 Ni5...Ni000 Cu0...Cu000 Res. linear Potenciômetro Valor mínimo -00 C -60 C -50 C 0 Ω 0 Ω Valor máximo +850 C +50 C +00 C 0 kω 00 kω Padrão IEC6075/JIS C 604 DIN 43760 α = 0,0047 - - Resistência de cabo por fio... 50 Ω Corrente de sensor... Nom. 0, ma Efeito da resistência do cabo do sensor (3-/4-linhas)... < 0,00 Ω / Ω 5350V-BR 5

Detecção de erro do sensor... Sim Detecção de curto-circuito... < 5 Ω Entrada TC: Tipo B E J K L N R S T U W3 W5 Ext. CJC Valor mínimo +400 C -00 C -00 C -80 C -00 C -80 C -50 C -50 C -00 C -00 C 0 C 0 C -40 C Valor máximo +80 C +000 C +00 C +37 C +900 C +300 C +760 C +760 C +400 C +600 C +300 C +300 C +35 C Pradão IEC584 IEC584 IEC584 IEC584 DIN 4370 IEC584 IEC584 IEC584 IEC584 DIN 4370 ASTM E988-90 ASTM E988-90 IEC6075 Compensação de junta fria (CJC)... < ±0,5 C Detecção de erro de sensor... Sim Corrente de erro de sensor: quando detectado... Nom. 4 μa ou... 0 μa Detecção de curto circuito... < 3 mv Entrada de tensão: Range de medição... -800...+800 mv Resistência de entrada... 0 MΩ Saída: Conexão PROFIBUS PA: Protocolo PROFIBUS PA... Profile A&B, ver. 3.0 Protocolo padrão PROFIBUS PA... EN 5070 vol. Endereço PROFIBUS PA address... 6 Bloco de função PROFIBUS PA... analógicos Conexão FOUNDATION Fieldbus: Protocolo FOUNDATION Fieldbus... Protocolo FF Protocolo padrão FOUNDATION Fieldbus... Especificação de design FF Capacidade FOUNDATION Fieldbus... Basic ou LAS Versão FOUNDATION Fieldbus... ITK 4.6 Blocos de função FOUNDATION Fieldbus... analógicas e PID 5350V-BR 6

Aprovações: EMC 004/08/EC... EN 636- EAC TR-CU 00/0... EN 636- I.S. / Ex: ATEX 94/9/EC 5350A... KEMA 03ATEX0 X 5350B... KEMA 0ATEX38 IECEx... IECEx BVS.0035 X FM... FM-305609 c CSA us... CSA-48937 INMETRO... NCC.009 X NEPSI 5350A... GYJ4.00U 5350B... GYJ4.0X EAC Ex TR-CU 0/0... RU C-DK.GB08.V.0040 5350V-BR 7

- - CONEXÕES DE ENTRADA Entrada: RTD, -linhas RTD, 3-linhas RTD, 4-linhas 3 4 5 6 3 4 5 6 3 4 5 6 x RTD, -linhas 3 4 5 6 x RTD, - / 3-linhas 3 4 5 6 resistência, -linhas 3 4 5 6 resistência, 3-linhas 3 4 5 6 resistência, 4-linhas 3 4 5 6 x resistência, - / 3-linhas 3 4 5 6 TC, CJC interna 3 4 5 6 TC, -linhas CJC externa 3 4 5 6 TC, 3-linhas CJC externa 3 4 5 6 - + - + - + x TC, CJC interna 3 4 5 6 x TC, -linhas CJC 3 4 5 6 3 mv 4 5 6 3 x mv 4 5 6 - + - + - + - + - + + + Potenciômetro, 3-linhas 3 4 5 6 Potenciômetro, compensação do cabo 3 4 5 6 Dois 3-linhas potenciômetros 3 4 5 6 S S Conexões com dois sensores pode ser configurado para medições, diferença, média ou redundância 5350V-BR 8

CONEXÕES DE SAÍDA Saída: Terminação do barramento Conexão do barramento Acoplador de barramento Terminação do barramento Conexão do barramento PA Acoplador de barramento Especificações mecânicas Montagem dos cabos do sensor + - + - 33 mm ø 44 mm ø 6 mm 0. m m As linhas devem ser montados entre as placas metálicas. 5350V-BR 9

DIAGRAMA DE BLOCO Entradas selecionáveis pelo usuário 6 5 4 3 Conversor analógico digital Isolação galvânica C PU EEPROM Configuração completa Coeficientes de correcção Configurações de fábrica Blocos de função Foundation Fieldbus AI, AI PID LAS Protocolo FOUNDATION PRO FIBUS Blocos de função PROFIBUS Protocolo 5350 Comutação automática entre os protocolos RTD Thermopar mv bipolar Ohm Potenciômetro Entrada Entrada CJC interna Bloco do transdutor Entrada Entrada Diferença Média Redundância Temperatura do terminal Unidades de engenharia Diagnóstico Linearização da tabela Linearização polinomial Processo de calibração AI, AI Conexão do barramento 5350V-BR 0

INSTALAÇÃO DE BARRAMENTO Acoplador de barramento PR5350A Alimentação PR5350A e e PR5350A DP PA Terminação do barramento FOUNDATION máx. 6 PROFIBUS máx. 3 Área segura Acoplador de barramento, Ex Área perigosa PR5350B PR5350B Alimentação, Ex Para acopladores de segmento adicionais PR5350B Terminação do barramento FOUNDATION máx. 0 PROFIBUS máx. 0 5350V-BR

APÊNDICE ATEX Installation Drawing - 5350B ATEX Installation drawing - 5350A FM & CSA Installation Drawing No. 5350QE0 NEPSI Installation Drawing IECEX Installation Drawing INMETRO Instruções de Segurança 5350V-BR

ATEX Installation Drawing - 5350B LERBAKKEN 0, 840 RØNDE DENMARK. 5350QE0 WWW.PRELECTRONICS.COM ATEX Installation drawing 5350 For safe installation of 5350A the following must be observed. The module shall only be installed by qualified personnel who are familiar with the national and international laws, directives and standards that apply to this area. Year of manufacture can be taken from the first two digits in the serial number. ATEX Certificate Marking KEMA 03ATEX 0X II 3 GD Ex na [nl] IIC T6..T4 II 3 GD Ex nl IIC T6..T4 II 3 GD Ex na [ic] IIC T6..T4 II 3 GD Ex ic IIC T6..T4 T4: -40 Ta 85ºC T6: -40 Ta 60ºC Standards EN 60079-0 : 006, EN 60079- : 007, EN 60079-5 : 005, EN 60079-7 : 006 Terminal: 3,4,5,6 Terminal:, Ex na Terminal:, Ex nl or Ex ic Terminal:, FNICO Uo: 5.7 V Io: 8.4 ma Po: mw Lo: 00 mh Co: 40 μf U 3 VDC Ui = 3 VDC Li = Ci =.0 nf Ui = 7.5 VDC Li = Ci =.0 nf Special conditions for safe use. For use in a potentially explosive atmosphere of flammable gasses, vapours or mists, the transmitter shall be mounted in an enclosure providing a degree of protection of at least IP54 in accordance to EN6059. For use in the presence of combustible dusts the transmitter shall be mounted in an enclosure providing a degree of protection of at least IP6X in accordance with o EN6059. The surface temperature of the enclosure shall be determined after installation of the transmitter. For an ambient temperature 60ºC, heat resistant cables shall be used with a rating of at least 0 K above the ambient temperature. Revision date: 05-0-7 Version /Revision V4/R0 5350QA0 VR0 Page: 3/5 5350V-BR 3

LERBAKKEN 0, 840 RØNDE DENMARK. 5350QE0 WWW.PRELECTRONICS.COM ATEX Installation drawing 5350 For safe installation of 5350B the following must be observed. The module shall only be installed by qualified personnel who are familiar with the national and international laws, directives and standards that apply to this area. Year of manufacture can be taken from the first two digits in the serial number. ATEX Certificate KEMA 0ATEX 38 Marking II G Ex ia IIC T6..T4 or II () G Ex ib [ia] IIC T6..T4 II D Ex iad Standards EN 60079-0 : 006, EN 60079- : 007, EN 60079-6 : 007, EN 64-0 : 006, EN 64- : 006, EN 60079-7 : 008 Hazardous area Zone 0,,, 0,, Non Hazardous Area 6 Segment Coupler 5 4 3 6 5 4 3 5350B 5350B Power Supply Max 0 modules 6 5 4 3 5350B Termination Revision date: 05-0-7 Version /Revision V4/R0 5350QA0 VR0 Page: /5 5350V-BR 4

ATEX Installation Drawing - 5350A LERBAKKEN 0, 840 RØNDE DENMARK. 5350QE0 WWW.PRELECTRONICS.COM Supply, terminal, for Ex ia IIC Supply, terminal, for Ex ib IIC Unit Barrier where Po < 0.84 W Barrier where Po <.3 W Suitable for FISCO systems Suitable for FISCO systems Unit Barrier where Po < 5.3 W FISCO segment coupler Ui Ii Pi Li Ci T..T4 T5 T6 30 VDC 0 madc 0.84 W Tamb.< 70ºC Tamb.< 60ºC 30 VDC 300 madc.3 W Tamb.< 75ºC Tamb.< 65ºC Tamb.< 45ºC 7.5 VDC 50 madc.0 W Tamb.< 60ºC Tamb.< 45ºC 5 VDC 900 madc 5.3 W Tamb.< 60ºC Tamb.< 45ºC Ui Ii Pi Li Ci T..T4 T5 T6 30 VDC 50 madc 5.3 W Tamb.< 75ºC Tamb.< 60ºC 7.5 VDC any any Tamb.< 75ºC Tamb.< 60ºC Sensor input, terminal 3,4,5 and 6 Uo... : 5.7 VDC Io... : 8.4 ma Po... : mw Lo... : 00 mh Co... : 40 µf Installation notes. The sensor circuit is not infallibly galvanic isolated from the input circuit. However, the galvanic isolation between the circuits is capable of withstanding a test voltage of 500Vac during minute. In a potentially explosive gas atmosphere, the transmitter shall be mounted in an enclosure in order to provide a degree of protection of at least IP0 according to EN6059. If the transmitter is installed in an explosive atmosphere requiring the use of equipment of category G and if the enclosure is made of aluminium, it must be installed such, that even in the event of rare incidents, ignition sources due to impact and friction, sparks are excluded; if the enclosure is made of non-metallic materials, electrostatic charging shall be avoided. For installation in a potentially explosive dust atmosphere, the following instructions apply: The transmitter shall be mounted in a metal enclosure form B according to DIN4379 that is providing a degree of protection of at least IP6X according to EN6059, that is suitable for the application and correctly installed. Cable entries and blanking elements shall be used that are suitable for the application and correctly installed. For an ambient temperature 60ºC, heat resistant cables shall be used with a rating of at least 0 K above the ambient temperature. The surface temperature of the enclosure is equal to the ambient temperature plus 0 K, for a dust layer with a thickness up to 5 mm. Revision date: 05-0-7 Version /Revision V4/R0 5350QA0 VR0 Page: /5 5350V-BR 5

FM / CSA Installation Drawing LERBAKKEN 0, 840 RØNDE DENMARK. 5350QE0 WWW.PRELECTRONICS.COM FM/CSA Installation drawing Hazardous (Classified) Location Class I,Division, Groups, A,B,C,D OR Class I, Zone 0, IIC 5350B 5350B Approved Termination 6 3 6 3 5 4 5 4 Terminal 3, 4, 5, 6 SENSOR SENSOR Vt or Uo : 5,7 V It or Io : 8,4 ma Pt or Po : mw Ca or Co : 40 uf La or Lo : 00 mh 5350B 6 3 5 4 SENSOR Unclassified Location Associated Apparatus Barrier or FISCO Supply with entity Parameters: UM < 50V Voc or Uo < Vmax or Ui Isc or Io < Imax or Ii Po < Pi Ca or Co > Ci + Ccable La or Lo > Li + Lcable This device must not be connected to any associated apparatus which uses or generates more than 50 VRMS Terminal, Class I, Zone 0, Ex ia IIC, Entity / FISCO IS, Class I, Division, Group A, B, C, D Entity / FISCO Barrier type: Linear barrier Trapezoid barrier Suitable for FISCO systems Suitable for FISCO systems T..T4: Ta +85 C Ta +75 C Ta +85 C Ta +85 C T5: Ta +70 C Ta +65 C Ta +60 C Ta +60 C T6: Ta +60 C Ta +45 C Ta +45 C Ta +45 C Vmax or Ui 30 V 30 V 7.5 V 5 V Imax or Ii 0 ma 300 ma 50 ma 900 ma Pi 0.84 W.3 W.0 W 5.3W Ci.0 nf.0 nf.0 nf.0 nf Li H H H H See Installation notes. Revision date: 05-0-7 Version /Revision V4/R0 5350QFC0 VR0 Page: 4/5 5350V-BR 6

LERBAKKEN 0, 840 RØNDE DENMARK. 5350QE0 WWW.PRELECTRONICS.COM Hazardous (Classified) Location Unclassified Location Class I,Division, Groups, A,B,C,D OR Class I, Zone, IIC Associated Apparatus Barrier with entity Parameters: Approved Termination Terminal 3, 4, 5, 6 Vt or Uo : 5,7 V It or Io : 8,4 ma Pt or Po : mw Ca or Co : 40 uf La or Lo : 00 mh 5350B 6 3 5 4 SENSOR 5350B 6 3 5 4 SENSOR 5350B 6 3 5 4 SENSOR UM < 50V Voc or Uo < Vmax or Ui Isc or Io < Imax or Ii Po < Pi Ca or Co > Ci + Ccable La or Lo > Li + Lcable or FISCO Supply This device must not be connected to any associated apparatus which uses or generates more than 50 VRMS Entity Parameters Terminal, Class I, Zone, Ex ib IIC Entity / FISCO Barrier type: Rectangular FISCO barrier Segment coupler T..T4: Ta +85 C Ta +85 C T5: Ta +75 C Ta +75 C T6: Ta +60 C Ta +60 C Vmax / Ui 30 V 7.5 V Imax or Ii 50 ma any Pi 5.3 W any Ci.0 nf.0 nf Li H H Installation notes. See Nonincendive Field Wiring parameters Terminal, NI, Class I, Division, Group A, B, C, D NIFW/ FNICO T..T4: Ta +85 C Ta +85 C T5: Ta +75 C Ta +75 C T6: Ta +60 C Ta +60 C Vmax / Ui 30 V 7.5 V Pi 5.3 W any Ci.0 nf.0 nf Li H H For a current-controlled circuit the parameter Imax is not required and need not be aligned with the parameter Isc or It of the barrier or associated nonincendive field wiring apparatus. Revision date: 05-0-7 Version /Revision V4/R0 5350QFC0 VR0 Page: 5/5 5350V-BR 7

LERBAKKEN 0, 840 RØNDE DENMARK. 5350QE0 WWW.PRELECTRONICS.COM Hazardous (Classified) Location Class I,Division, Groups, A,B,C,D OR Class I, Zone, IIC Unclassified Location 3V Class Power Supply Approved Termination 6 5350A 5 4 SENSOR 3 5350A SENSOR 5350A SENSOR This device must not be connected to any associated apparatus which uses or generates more than 50 VRMS Terminal 3, 4, 5, 6 Vt or Uo : 5.7 V It or Io : 8.4 ma Pt or Po : mw Ca or Co : 40 F La or Lo : 00 mh Terminal. Ci:.0 nf Li: H T..T4 T5 T6-40 C Ta +85 C -40 C Ta +75 C -40 C Ta +60 C See installation notes: Revision date: 05-0-7 Version /Revision V4/R0 5350QFC0 VR0 Page: 6/5 5350V-BR 8

LERBAKKEN 0, 840 RØNDE DENMARK. 5350QE0 WWW.PRELECTRONICS.COM Installation notes: FM / CSA: For installation in the US the 5350 shall be installed according to the National Electrical Code (ANSI-NFPA 70). For installation in Canada the transmitter shall be installed in a suitable enclosure to meet installation codes stipulated in the Canadian Electrical Code (CEC). The entity concept: Equipment that is FM / CSA-approved for intrinsic safety may be connected to barriers based on the ENTITY CONCEPT. This concept permits interconnection of approved transmitters, meters and other devices in combinations which have not been specifically examined by FM / CSA, provided that the agency's criteria are met. The combination is intrinsically safe, if the entity concept is acceptable to the authority having jurisdiction over the installation. The entity concept criteria are as follows: The intrinsically safe devices, other than barriers, must not be a source of power. The maximum voltage Ui (VMAX) and current Ii (IMAX), and maximum power Pi (Pmax), which the device can receive and remain intrinsically safe, must be equal to or greater than the voltage (Uo or VOC or Vt) and current (Io or ISC or It) and the power Po which can be delivered by the barrier. The sum of the maximum unprotected capacitance (Ci) for each intrinsically device and the interconnecting wiring must be less than the capacitance (Ca) which can be safely connected to the barrier. The sum of the maximum unprotected inductance (Li) for each intrinsically device and the interconnecting wiring must be less than the inductance (La) which can be safely connected to the barrier. The entity parameters Uo,VOC or Vt and Io,ISC or It, and Ca and La for barriers are provided by the barrier manufacturer. FISCO/FNICO rules: The FISCO Concept allows the interconnection of intrinsically safe apparatus to associated apparatus not specifically examined in such combination. The criterion for such interconnection is that the voltage (Vmax), the current (Imax) and the power (Pi) which intrinsically safe apparatus can receive and remain intrinsically safe, considering faults, must be equal or greater than the voltage (Uo, Voc, Vt), the current (Io, Isc, It,) and the power (Po) which can be provided by the associated apparatus (supply unit). In addition, the maximum unprotected residual capacitance (Ci) and inductance (Li) of each apparatus (other than the terminators) connected to the Fieldbus must be less than or equal to: FISCO: 5 nf and 0 H. FNICO: 5 nf and 0 H Revision date: 05-0-7 Version /Revision V4/R0 5350QFC0 VR0 Page: 7/5 5350V-BR 9

LERBAKKEN 0, 840 RØNDE DENMARK. 5350QE0 WWW.PRELECTRONICS.COM The Nonincendive Field Wiring concept allows the interconnection of nonincendive field wiring apparatus using any of the wiring methods permitted for unclassified locations. Vmax >= Voc or Vt, Ca >= Ci +Ccable, La >= Li + Lcable" The Nonincendive Field Wiring concept allows the interconnection of FM-approved nonincendive devices with FNICO parameters not specifically examined in combination as a system when: Uo or Voc or Vt <= Vmax, Po <= Pi In each I.S. Fieldbus segment only one active source, normally the associated apparatus, is allowed to provide the necessary power for the Fieldbus system. The allowed voltage (Uo, Voc, Vt) of the associated apparatus used to supply the bus must be limited to the range of 4V d.c. to 4V d.c. All other equipment connected to the bus cable has to be passive, meaning that the apparatus is not allowed to provide energy to the system, except to a leakage current of 50 A for each connected device. Separately powered equipment needs a galvanic isolation to insure that the intrinsically safe Fieldbus circuit remains passive. The cable used to interconnect the devices needs to comply with the following parameters: Loop resistance R': 5...50 /Km Inductance per unit length L': 0.4 mh/km Capacitance per unit length C': 80...00 nf/km C' = C' line/line + 0.5 C' line/screen, if both lines are floating or C'= C' line/line + C' line/screen, if the screen is connected to one line Length of spur Cable: max. 30 m Length of trunk cable: max. Km Length of splice: max. m Terminators At each end of the trunk cable an approved line terminator with the following parameters is suitable: R = 90...00 C = 0... F. System evaluation The number of passive devices like transmitters, actuators, connected to a single bus segment is not limited due to I.S. or N.I. reasons. Furthermore, if the above rules are respected, the inductance and capacitance of the cable need not to be considered and will not impair the intrinsic safety or nonincendive safety of the installation as applicable. The sensor circuit is not infallibly galvanically isolated from the Fieldbus input circuit. However, the galvanic isolation between the circuits is capable of withstanding a test voltage of 500 Vac during minute. Revision date: 05-0-7 Version /Revision V4/R0 5350QFC0 VR0 Page: 8/5 5350V-BR 0

LERBAKKEN 0, 840 RØNDE DENMARK. 5350QE0 WWW.PRELECTRONICS.COM Nonincendive Field Wiring Concept: The Nonincendive Field Wiring concept allows for the interconnection of nonincendive field wiring apparatus using any of the wiring methods permitted for unclassified locations. Vmax >= Voc or Vt, Ca >= Ci +Ccable, La >= Li + Lcable" Installation Notes For FISCO and Entity Concepts:. The Intrinsic Safety Entity concept allows the interconnection of FM / UL / CSAapproved intrinsically safe devices (Div. or Zone 0 or Zone), with entity parameters not specifically examined in combination as a system when: Uo or Voc or Vt Vmax, Io or Isc or It Imax, Po Pi. Ca or Co Ci + Ccable, La or Lo Li + Lcable, Po Pi.. The Intrinsic Safety FISCO concept allows the interconnection of FM / UL / CSAapproved intrinsically safe devices with FISCO parameters not specifically examined in combination as a system when: Uo or Voc or Vt Vmax, Io or Isc or It Imax, Po Pi. 3. Control equipment connected to the Associated Apparatus must not use or generate more than 50 Vrms or Vdc. 4. Intrinsically Safe Installation should be in accordance with ANSI/ISA RP.6.0 (except chapter 5 for FISCO Installations) Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations and the National Electrical Code (ANSI/NFPA 70) Sections 504 and 505. 5. The configuration of associated Apparatus must be FM Approvals or UL / CSA Approved under the associated concept. 6. Associated Apparatus manufacturer s installation drawing must be followed when installing this equipment. 7. The 5350B is approved for Class I, Zone 0, applications. If connecting AEx[ib] associated Apparatus or AEx ib I.S. Apparatus to the 5350B the I.S. circuit is only suitable for Class I, Zone, or Class I, Zone, and is not suitable for Class I, Zone 0 or Class I, Division, Hazardous (Classified) Locations". 8. No revision to drawing without prior FM / UL / CSA Approval. 9. Simple Apparatus is defined as a device that neither generates nor stores more than.5 V, 0. A or 5 mw. 0. The termination must be NRTL-approved, and the resistor must be infallible.. Warning: For applications in Div. or Zone (Classified Locations) Explosion hazard: Except for nonincendive field circuits, do not disconnect the apparatus unless the area is known to be non hazardous.. Warning: Substitution of Components May Impair Safety. Revision date: 05-0-7 Version /Revision V4/R0 5350QFC0 VR0 Page: 9/5 5350V-BR

NEPSI Installation Drawing 5350QE0 LERBAKKEN 0, 840 RØNDE DENMARK. WWW.PRELECTRONICS.COM NEPSI Installation drawing Transmitter with Bus technology of Series 5350A manufactured by PR electronics A/S via the test made by NEPSI (National Supervision and Inspection Center for Explosion Protection and Safety of Instrumentation have been proved that they are fulfilling the General Requirements according to Article I, GB3836.-00 Electrical equipement using in the Explosive gas Environment and the specified requirements for n series in Article IX, GB3836.8-003. The symbol of explosive protection applied should be Ex na(l) II C T4~T6 while the Certificate No. is GYJ4.00U. Firstly, Note for the use of the products. The Symbol U applied after the Cert. No., indicates that this transmitter cannot be applied in explosive environment of danget until the Protection Grade of the box where the transmitter will later on be placed is not lower than IP54 (GB408), and has been approved by the National Authorized Inspection Body.. The rated Voltage for the transmitter should be 3Vd.c. Proper measures should be applied to protect the working voltage from instantaneously jumping up to 40% of the rated Voltage caused by disturbance. 3. The relationship between the temperature Code and ambient temperature is indicated as follows: Temperature Code Ambient Temperature T4-40~+85 T5-40~+75 T6-40~+60 4. the parameters of the transmitter output which will be connected with the inputs of the Sensor (X3, X4, X5, X6) are as follows: Uo=5.7V Io=8.4V Po=mW Co=40 μ F lo=00 mh 5. Only when the transmitter is combined with other power-restraint devices which have also been tested and approved by the National Authorized Inspection Body and met the requirements of GB3836.-000 and GB3836.8-000 can the explosion protection system be applied in the explosive environment. Uo<Ui Io<Ii Po Pi Co Cc+Ci Lo Lc+Li Note: Cc, Lc indicated the parameters of distributed electric capacity of connecting cable. Ui, Ii, Pi indicted the parameters of the output of other power-restraint devices; Ci, Li indicated the maximum of the external parameter of the power-restraint devices. 6. Users are not allowed to replace the inner electrical parts with permission. 7. The installation, implementation and maintenance of the transmitter should strictly conform to the Regulation of Design Code for electricity Equipment used in explosive and flammable environment in GB50058-99 and installation of Electrical Equipment in Dangerous Environment the Article 5, Electrical Equipment of explosive gas Environment of GB3836.5-000. Revision date: 05-0-7 Version /Revision V4/R0 5350QFC0 VR0 Page: 0/5 5350V-BR

LERBAKKEN 0, 840 RØNDE DENMARK. 5350QE0 WWW.PRELECTRONICS.COM Transmitter with Bus technology of Series 5350B manufactured by PR electronics A/S via the test made by NEPSI (National Supervision and Inspection Center for Explosion Protection and Safety of Instrumentation) have been proved that they are fulfilling the General Requirements according to, GB 3836.-00, GB3836.4-00, GB3836.0-00. The symbol of explosive protection are EX ia IIC T4~T6 or Ex ib(ia) IIC T4~T6 while the Certificate No. is GYJ4.0X. Note for the use of transmitter:. The Symbol X applied after the Cert. No., indicates that this transmitter cannot be applied in explosive environment of danger until the Protection Grade of the box where the transmitter will later on be placed is not lower thant IP0 (GB408), and has been approved by the National Authorized Inspection Body. The metallic case must accord to item 8, GB3836.-00; the nonmetallic case must accord to item 7.3, GB3836.-00.. The relationship of the explosive protection ingress, the temperature Code, ambient temperature and max. output parameter is indicated as follows: Ex ia IIC Ex ib(ia) II C T4: -40 C~+85 C -40 C~+75 C -40 C~+85 C -40 C~+85 C T5-40 C~+70 C -40 C~+65 C -40 C~+60 C -40 C~+75 C T6: -40 C~+60 C -40 C~+45 C -40 C~+45 C -40 C~+60 C Ui 30V 30V 7.5V 30V Li 0mA 300mA 50mA 50mA Pi 0.84W.3W.0W 5.3W Ci= nf, Li=µH Revision date: 05-0-7 Version /Revision V4/R0 5350QFC0 VR0 Page: /5 5350V-BR 3

IECEx Installation Drawing LERBAKKEN 0, 840 RØNDE DENMARK. 5350QE0 WWW.PRELECTRONICS.COM IECEx Installation drawing For safe installation of 5350 the following must be observed. The module shall only be installed by qualified personnel who are familiar with the national and international laws, directives and standards that apply to this area. Year of manufacture can be taken from the first two digits in the serial number.. IECEx Certificate BVS.0035X Marking Ex ia IIC T6..T4 Ga Ex ib [ia Ga] IIC T6..T4 Gb Ex ia IIIC T35 C Da Ex ia I Ma Ex na [ic] IIC T6..T4 Gc Ex ic IIC T6..T4 Gc Standards IEC60079-:0, IEC60079-0: 0, IEC60079-5: 00 Hazardous area Zone 0,,, 0,,, M Non Hazardous Area 6 Segment Coupler 5 4 3 Power Supply 6 5 4 Sensor input terminals 3,4,5,6 Uo 5.7 VDC Io 8.4 ma Po mw Lo 00 mh Co 40 µf 3 Max 0 modules 6 5 4 3 Termination Revision date: 05-0-7 Version /Revision V4/R0 5350QI0 VR0 Page: /5 5350V-BR 4

LERBAKKEN 0, 840 RØNDE DENMARK. 5350QE0 WWW.PRELECTRONICS.COM Unit Supply, terminal, Ex ia IIC T6..T4 Ga or Ex ia IIIC Da or Barrier where Po < 0.84 W Ui 30 VDC Ii 0 madc Pi 0.84 W Li Ci T..T4 T5 Tamb.< 70ºC T6 Tamb.< 60ºC Barrier where Po <.3 W 30 VDC 300 madc.3 W Tamb.< 75ºC Tamb.< 65ºC Tamb.< 45ºC Suitable for FISCO systems 7.5 VDC 50 madc.0 W Tamb.< 60ºC Tamb.< 45ºC Ex ia I Ma Suitable for FISCO systems 5 VDC 900 madc 5.3 W Tamb.< 60ºC Tamb.< 45ºC Unit Supply, terminal, Ex ib [ia Ga] IIC T6..T4 Gb Barrier where Po < 5.3 W Ui 30 VDC Ii 50 madc Pi 5.3 W Li Ci T..T4 T5 Tamb.< 75ºC T6 Tamb.< 60ºC FISCO segment coupler 7.5 VDC any any Tamb.< 75ºC Tamb.< 60ºC Supply, terminal, Ex na [ic] IIC T6..T4 Gc or Ex ic IIC T6..T4 Gc Ui Li Ci T..T4 T5 T6 Max 3 VDC Tamb.< 75ºC Tamb.< 60ºC Installation notes. The sensor circuit is not infallibly galvanic isolated from the input circuit. However, the galvanic isolation between the circuits is capable of withstanding a test voltage of 500Vac during minute. For an ambient temperature 60ºC, heat resistant cables shall be used with a rating of at least 0 K above the ambient temperature For installation in a potentially explosive gas atmosphere requiring EPL Ga or EPL Gb, the following instructions apply: The transmitter shall be mounted in an enclosure that is providing a degree of protection of at least IP54 according to IEC 6059 that is suitable for the application and correctly installed. For installation in a potentially explosive dust atmosphere requiring EPL Da or EPL Db, the following instructions apply: The transmitter shall be mounted in an Form B enclosure according to DIN 4379, that is providing a degree of protection of at least IP6X according to IEC 60079-0 and IEC 60079-3 Equipment dust ignition protection by enclosure td that is suitable for the application and correctly installed. Cable entries and blanking elements shall be used that are suitable for the application and correctly installed. Maximum surface temperature with a 5 mm layer of dust is T 35 C. For installation in mines the following instructions apply: The transmitter shall be mounted in a metal enclosure that is providing a degree of protection of at least IP6X according to IEC 6059, and is suitable for the application and correctly installed. Cable entries and blanking elements shall be used that are suitable for the application and correctly installed For installation in a potentially explosive gas atmosphere requiring EPL Gc the following instructions apply: The transmitter shall be mounted in an enclosure according to IEC 60079-5, that is suitable for the application and correctly installed. Revision date: 05-0-7 Version /Revision V4/R0 5350QI0 VR0 Page: 3/5 5350V-BR 5

LERBAKKEN 0, 840 RØNDE DENMARK. 5350QE0 WWW.PRELECTRONICS.COM INMETRO Instruções de Segurança. Dados Ex: Ex ia IIC T6 T4 Ga Ex ib [ia Ga] IIC T6...T4 Gb Ex ia IIIC T 35 C Da Ex ia I Ma Ex na [ic] T6... T4 Gc Ex ic IIC T6...T4 Gc Certificado:: NCC.009 X Instalação Ex: Para a instalação segura do transmissor 5350B em áreas classificadas, deve-se observar o seguinte: O módulo necessita ser instalado somente por pessoal qualificado e que tenham familiaridade com normas internacionais, diretivas e normalização aplicadas à estas áreas. O ano de fabricação do instrumento pode ser obtido, observando-se os primeiros dois dígitos do seu número de série. O circuito do sensor não está com isolação galvânica total em relação ao circuito de entrada. Todavia a isolação galvânica entre os circuitos é capaz de suportar teste de voltagem de 500Vac durante minuto. O transmissor precisa ser montado em um invólucro com um grau de proteção pelo menos IP-0. Em atmosferas explosivas compostas por misturas de ar / poeira: O transmissor somente poderá ser instalado em uma atmosfera potencialmente explosiva composta por poeira combustível se estiver montado no interior de um invólucro metálico forma B de acordo com a norma DIN 4379 com um grau de proteção pelo menos IP-6X de acordo com a norma IEC 6059, que seja adequado para esta aplicação e corretamente instalado. As entradas dos cabos e outras barreiras a serem utilizadas devem ser adequadas e corretamente instaladas. Onde a temperatura ambiente for 60ºC, devem ser utilizados cabos resistentes ao calor que resistam pelo menos 0K acima da temperatura ambiente. Se o invólucro onde o transmissor está montado for feito de alumínio e instalado em Zona 0, ou Zona 0, ou, este não deve conter mais do que 6% do seu peso total de magnésio e titânio. Acessórios adicionais ao invólucro devem ser projetados e/ou instalados de tal modo que até mesmo eventos de rara incidência, fontes de ignição causadas por impactos e faíscas por fricção sejam excluídas. Revision date: 05-0-7 Version /Revision V4/R0 Doc. No. 5350QB0 VR0 Page: 4/5 5350V-BR 6

LERBAKKEN 0, 840 RØNDE DENMARK. 5350QE0 WWW.PRELECTRONICS.COM Sinal de saída / alimentação, terminal e Ex ia IIC T6... T4 Ga FISCO Temp. ambiente max. depende de Po da barreira conectada. Unidade Barreira onde Po < 0.85 W Barreira onde Po <.3 W Adequado parasistemas FISCO Adequado parasistemas FISCO Ui Ii Pi Li Ci T..T4 T5 T6 Group I 30 VDC 0 madc 0.84 W Tamb.< 70ºC Tamb.< 60ºC 30 VDC 300 madc.3 W Tamb.< 75ºC Tamb.< 65ºC Tamb.< 45ºC 7.5 VDC 50 madc.0 W Tamb.< 60ºC Tamb.< 45ºC 5 VDC 900 madc 5.3 W Tamb.< 60ºC Tamb.< 45ºC Sinal de saída / alimentação, terminal e Ex ib [ia Ga] IIC T6... T4 Gb FISCO Temp. ambiente max. depende de Po da barreira conectada. Sinal de saída / alimentação, terminal e Ex ic IIC T6... T4 Gc FISCO Temp. ambiente max. depende de Po da barreira conectada. Unidade Ui Ii Pi Li Ci T..T4 T5 T6 Group I Barrier where Po < 5.3 W 30 VDC 50 madc 5.3 W Tamb.< 75ºC Tamb.< 60ºC FISCO segment coupler 7.5 VDC Qualquer Qualquer Tamb.< 75ºC Tamb.< 60ºC Unidade Ui Ii Pi Li Ci T..T4 T5 T6 Group I 3 VDC Qualquer Qualquer Tamb.< 75ºC Tamb.< 60ºC Entrada do sensor, terminais 3, 4, 5 e 6: Uo... : 5,7 VDC Io... : 8,4 ma Po... : mw Lo...: 00 mh Co... : 40 µf Revision date: 05-0-7 Version /Revision V4/R0 Doc. No. 5350QB0 VR0 Page: 5/5 5350V-BR 7

Displays Displays programáveis com uma grande variedade de entradas e saídas para monitoramento de temperatura, volume e peso, etc. Características de linearização, escala, e diferentes funções de medição para programar via software PReset. Interfaces EX Interfaces para sinais digitais e analógicos bem como sinais HART entre sensores / conversores I/P / sinais de frequência e sistema de controle em área EX 0, e e para alguns módulos em área 0, e. Isolação Isoladores galvânicos para sinais digitais e analógicos bem como sinais HART. Uma grande variedade de produtos ambos passivos e isoladores universais com linearização, inversão, e escala de sinal de saída. Temperatura Uma grande variedade de transmissores para montagem em trilho DIN com barramento de comunicação analógica e digital, variando conforme aplicação, específico para transmissores universais. Universal Módulos programáveis via PC ou display frontal com entradas, saídas e alimentação universal. Esta variedade oferece algumas características avançadas como processo de calibração, linearização e auto-diagnóstico.

www.prelectronics.fr sales-fr@prelectronics.com www.prelectronics.de sales-de@prelectronics.com www.prelectronics.es sales-es@prelectronics.com www.prelectronics.it sales-it@prelectronics.com www.prelectronics.se sales-se@prelectronics.com www.prelectronics.com sales-uk@prelectronics.com www.prelectronics.com sales-us@prelectronics.com www.prelectronics.cn sales-cn@prelectronics.com www.prelectronics.be sales-be@prelectronics.com Sede Dinamarca www.prelectronics.com PR electronics A/S sales@prelectronics.dk Lerbakken 0 tel. +45 86 37 6 77 DK-840 Rønde fax +45 86 37 30 85