Motors Automation Energy Transmission & Distribution Coatings. PROFIBUS DP Communication Plug-in Module. Módulo Plug-in de Comunicación PROFIBUS DP

Documentos relacionados
Motors Automation Energy Transmission & Distribution Coatings. Digital I/Os Plug-in Module. Módulo Plug-in de Expansión de I/Os Digitales

Motors Automation Energy Transmission & Distribution Coatings

Motors Automation Energy Transmission & Distribution Coatings

Motors Automation Energy Transmission & Distribution Coatings. Analog and Digital I/O Plug-in Module

Motors Automation Energy Transmission & Distribution Coatings. I/O Expansion Module NPN/ PNP Digital Inputs

Motors Automation Energy Transmission & Distribution Coatings

Motors Automation Energy Transmission & Distribution Coatings

Motors Automation Energy Transmission & Distribution Coatings. Bluetooth Communication Module. Módulo de Comunicación Bluetooth

Motors Automation Energy Transmission & Distribution Coatings. USB Plug-in Module Módulo Plug-in USB

Motors Automation Energy Transmission & Distribution Coatings. USB Plug-in Module Módulo Plug-in USB

Motors Automation Energy Transmission & Distribution Coatings. Módulo de Expansión de I/O. Módulo de Expansão de I/O

Motors Automation Energy Transmission & Distribution Coatings. Módulo de Expansión de I/O. Módulo de Expansão de I/O

Motors Automation Energy Transmission & Distribution Coatings

Motors Automation Energy Transmission & Distribution Coatings

Motors Automation Energy Transmission & Distribution Coatings

Motors Automation Energy Transmission & Distribution Coatings. Ethernet Communication Plug-in Module

Motors Automation Energy Transmission & Distribution Coatings. CAN Communication Module. Módulo de Comunicación CAN. Módulo de Comunicação CAN

Motors Automation Energy Transmission & Distribution Coatings. CAN Communication Module. Módulo de Comunicación CAN. Módulo de Comunicação CAN

Motors Automation Energy Transmission & Distribution Coatings. MMF-03-SP Memory Module

Motors Automation Energy Transmission & Distribution Coatings. Módulo de Memoria Flash. Módulo de Memória Flash

Motors Automation Energy Transmission & Distribution Coatings. ENC Encoder Input Plug-in Module. Módulo Plug-in con Entrada de Encoder ENC

Motors Automation Energy Transmission & Distribution Coatings. Módulo de Memoria Flash. Módulo de Memória Flash

Motors Automation Energy Transmission & Distribution Coatings

Motors Automation Energy Transmission & Distribution Coatings. Bluetooth Communication Module. Módulo de Comunicación Bluetooth

Motors Automation Energy Transmission & Distribution Coatings KPCSD - KPCSE CFW500

Digital Inputs and Outputs Expansion Kit Kit de Expansión de Entradas y Salidas Digitales Kit de Expansão de Entradas e Saídas Digitais

IOC-01, IOC-02 and IOC-03 Module Módulo IOC-01, IOC-02 y IOC-03 Módulo IOC-01, IOC-02 e IOC-03

Anybus-CC Module. Módulo Anybus-CC. Módulo Anybus-CC. Installation, Configuration Guía de Instalación, Guia de Instalação,

Anybus-CC Modules. Módulos Anybus-CC. Módulos Anybus-CC. Installation, Configuration Guía de Instalación, Guia de Instalação,

Motors Automation Energy Transmission & Distribution Coatings

Frequency Inverter. Convertidor de Frecuencia. Inversor de Frequência. CFW-11 Sizes/Mec. E, F, G CFW-11M

Kit Tecsystem for MVW-01. Kit Tecsystem para MVW-01. Kit Tecsystem Installation, Configuration and Operation Guide

Current Measurement Unit - UMC Unidad de Medición de Corriente - UMC Unidade de Medição de Corrente - UMC

Motors Automation Energy Transmission & Distribution Coatings. Módulo de Expansión de I/O. Módulo de Expansão de I/O

RS-485 Kit. Kit RS-485. Kit RS-485. SSW-07 / SSW-08 English / Español / Português Document: / 04. Installation Guide. Guia de Instalación

Memory Module MMF-02. Modulo de Memoria MMF-02. Módulo de Memória MMF-02 CFW70X

RS-232 / RS-485 / CAN / PROFIBUS DP Modules Módulos RS-232 / RS-485 / CAN / PROFIBUS DP Módulos de Interface RS-232 / RS-485 / CAN / PROFIBUS DP

Flash Memory Module. Módulo de Memoria Flash. Módulo de Memória Flash CFW500

IOA-01 and IOB-01 Module Módulo IOA-01 y IOB-01 Módulo IOA-01 e IOB-01

PLC11-01 Board Tarjeta PLC11-01 Cartão PLC11-01

Expansion Module of Relay Outputs. Módulo de Expansión de Salidas a Relé. Módulo de Expansão de Saídas a Relé

CVW500 - KCP-500. Power Conectors Kit KCP-500. Kit de Conectores de Potencia KCP-500. Kit de Conectores de Potência KCP-500

DeviceNet Communication Kit Kit de Comunicación DeviceNet Kit de Comunicação DeviceNet

Motors Automation Energy Transmission & Distribution Coatings. Módulo de Memoria Flash. Módulo de Memória Flash

1. KIT DESCRIPTION 1. DESCRIPCION DEL KIT 1. DESCRIÇÃO DO KIT

PLC11-01 Module Módulo PLC11-01 Módulo PLC11-01

CEM SCA-05 KIT KIT CEM SCA-05. CEM SCA-05 Kit Installation Guide. Kit CEM SCA-05 Guía de Instalación. Kit CEM SCA-05 Guia de Instalação

Encoder Input Expansion Module - EEN2 Módulo de Expansión de Entradas de Encoder - EEN2 Módulo de Expansão de Entradas de Encoder - EEN2

KPC Protection Kit. Kit de Protección KPC. Kit de Proteção KPC SSW-06. Installation Guide Guía de Instalación Guia de Instalação

Expansion Module for Communication Módulo de Expansión de Comunicación Módulo de Expansão de Comunicação

Motors Automation Energy Transmission & Distribution Coatings. Infrared Remote Control and I/O Expansion Module

Motor PTC Kit. Kit PTC del Motor. Kit PTC do Motor SSW-07 / SSW-08

External Current Acquisition Kit Kit de Adquisición de Corriente Externa Kit Aquisição de Corrente Externa SSW-06

SCA06. Installation, Configuration and Operation Guide Guía de Instalación, Configuración y Operación Guia de Instalação, Configuração e Operação

Enclosure Size 2 Ventilation Kit. Kit Ventilación para Tamaño 2. Kit Ventilação para Mecânica 2. Installation Guide. Guia de Instalación

Remote Keypad and RS-485 Modbus RTU Kit Kit HMI Remota y RS-485 Modbus RTU Kit HMI Remota e RS-485 Modbus RTU

Rack 2 / Rack 3 CFW-11M / RMW11

Módulo de Expansão de Entradas e Saídas Digitais - EIO1

Motors Automation Energy Transmission & Distribution Coatings. Módulo de Memoria Flash. Módulo de Memória Flash

Dynamic Braking. Módulo DBW-01 e DBW-02. Módulo de Freno Dinámico DBW-01 y DBW-02 Módulo de Frenagem Reostática DBW-01 e DBW-02

Expansion Digital Unit - EDU Unidad de Expansión Digital - EDU Unidade de Expansão Digital - EDU

KME Kit Size 9, 10 and 10E Kit KME Tamaño 9, 10 y 10E. Mecânica 9, 10 e 10E. CFW-09 English / Español / Português Document: 0899.

Unidade Remota CANopen RUW-06. Guia de Instalação, Configuração e Operação. Idioma: Português. Documento: / 00

RS-485 Communication Kit Kit de Comunicación RS-485 Kit de Comunicação RS-485 SSW-06. Installation Guide Guía de Instalación Guia de Instalação

SRW 01-HMI. Remote Keypad (HMI) HMI Remoto HMI Remota. Installation Guide Guía de Instalación Guia de Instalação. English / Español / Português

Frequency Inverter Convertidor de Frecuencia Inversor de Frequência APW11

Unidade Remota CANopen RUW-03. Guia de Instalação, Configuração e Operação. Documento: / 00

Smart Relay Relé Inteligente SRW 01-UMCT

Frequency Inverter Convertidor de Frecuencia Inversor de Freqüência CFW-11 PLC11-02

Motors Automation Energy Transmission & Distribution Coatings. Módulo de Memoria Flash. Módulo de Memória Flash

Unidade Remota CANopen RUW-05. Guia de Instalação, Configuração e Operação. Documento: / 00

CEP1 Board. Tarjeta CEP1. Cartão CEP1. CEP1 board Installation Guide. Tarjeta CEP1. Guía de Instalación. Cartão CEP1. Guia de Instalação

WI180C-PB. Sem data Sheet online

USB Communication Kit Kit de Comunicación USB Kit de Comunicação USB SSW-06

Installation, Configuration and Operation Guide Guía de Instalación, Configuración y Operación Guia de Instalação, Configuração e Operação

KME Kit - Size 7 Kit KME - Tamaño 7 Kit KME - Mecânica 7

SCA-05 Communication Board Kit (COM5) Kit con Tarjeta de Comunicación del SCA-05 (COM5) Kit com Placa de Comunicação do SCA-05 (COM5)

INSTALLATION GUIDE MANUAL DE INSTALAÇÃO MANUAL DE INSTALACIÓN

Módulo de Expansão de Entrada de Encoder EEN1 SCA06

Instructions AK-PC 551

SONDA CASCATA. Avisos preliminares CONTEÚDO FERRAMENTAS RECOMENDADAS NEXPOLAR

KME Kit - Size 7 Kit KME - Tamaño 7 Kit KME - Mecânica 7

Frequency Inverter. Convertidor de Frecuencia. Inversor de Frequência. CFW-11 Sizes/Mec. E, F, G CFW-11M

Smart Relay Relé Inteligente SRW 01 ELS

Instructions AK-PC 651

Módulo de Expansão de Entradas de Encoder EEN2 SCA06

SONDA DE ÁGUA QUENTE SANITÁRIA

INSTALLATION GUIDE MANUAL DE INSTALAÇÃO MANUAL DE INSTALACIÓN

Instructions AK-PC 351

Installation, Configuration and Operation Guide Guía de Instalación, Configuración y Operación Guia de Instalação, Configuração e Operação

NETWORK DeviceNet e Profibus DP Expansion Module 4 Digital Inputs - KDC-4EP (-P)

EtherNet/IP Fieldbus Kit

Installation, Configuration and Operation Guide Guía de Instalación, Configuración y Operación Guia de Instalação, Configuração e Operação

Interface Module WEG MIW-02 Módulo de Interface WEG MIW-02

INSTALLATION GUIDE MANUAL DE INSTALAÇÃO MANUAL DE INSTALACIÓN

INSTALLATION GUIDE MANUAL DE INSTALAÇÃO MANUAL DE INSTALACIÓN

Encoder Input Expansion Module - EEN1 Módulo de Expansión de Entrada de Encoder - EEN1 Módulo de Expansão de Entrada de Encoder - EEN1

User Guide. Wiegand Reader AR-721U/ AR-721K/ AR-661U V060419

CONECTOR CUNHA WEDGE CONNECTOR - CONECTOR TIPO CUÑA. Conector Cunha para Ramal de Ligação (Simétrico) - CCRL

Transcrição:

Motors Automation Energy Transmission & Distribution Coatings PROFIBUS DP Communication Plug-in Module Módulo Plug-in de Comunicación PROFIBUS DP Módulo Plug-in de Comunicação PROFIBUS DP CFW500 Installation, Configuration and Operation Guide Guía de Instalación, Configuración y Operación Guia de Instalação, Configuração e Operação

Summary / Índice ÍNDICE 1 SAFETY INFORMATION...5 1.1 SAFETY WARNINGS...5 1.2 PRELIMINARY RECOMMENDATIONS...5 English 2 GENERAL INFORMATION...5 3 CONTENTS OF THE PACKAGE...5 4 ACCESSORY INSTALLATION...6 5 SETTINGS...6 APPENDIX A FIGURES...23 ÍNDICE 1 INFORMACIONES DE SEGURIDAD...11 1.1 AVISOS DE SEGURIDAD... 11 1.2 RECOMENDACIONES PRELIMINARES... 11 2 INFORMACIONES GENERALES...11 3 CONTENIDO DEL EMBALAJE...11 Español 4 INSTALACIÓN DEL ACCESORIO...12 5 CONFIGURACIONES...12 ANEXO A FIGURAS...23 ÍNDICE 1 INFORMAÇÕES DE SEGURANÇA...17 1.1 AVISOS DE SEGURANÇA... 17 1.2 RECOMENDAÇÕES PRELIMINARES... 17 2 INFORMAÇÕES GERAIS...17 3 CONTEÚDO DA EMBALAGEM...17 4 INSTALAÇÃO DO ACESSÓRIO...18 5 CONFIGURAÇÕES...18 ANEXO A FIGURAS...23 Português

PROFIBUS DP Communication Plug-in Module 1 SAFETY INFORMATION 1.1 SAFETY WARNINGS English NOTE! Only use the PROFIBUS DP communication plug-in module (CFW500-CPDP or CFW500-CPDP2) on WEG inverters of the CFW500 line. Read the user s manual of the CFW500 and the user s manual of the PROFIBUS DP before installing or operating this accessory. This guide contains important information for the correct understanding and proper operation of this module. 1.2 PRELIMINARY RECOMMENDATIONS ATTENTION! Always disconnect the general power supply before connecting or disconnecting the accessories of the frequency inverter CFW500. Wait for at least 10 minutes to guarantee complete de-energization of the inverter. 2 GENERAL INFORMATION This guide contains instructions for the installation, configuration and operation of the PROFIBUS DP communication plug-in module (CFW500-CPDP or CFW500-CPDP2). 3 CONTENTS OF THE PACKAGE When receiving the product, check if this package contains: Accessory in anti-static packaging. Installation, configuration and operation guide. CFW500 5

PROFIBUS DP Communication Plug-in Module English 4 ACCESSORY INSTALLATION The accessory is easily installed or replaced. For correct installation of the accessory execute the following steps: Step 1: With the inverter de-energized, remove the front cover of the Inverter (figure A.1 (a)). Step 2: Remove, if present, the accessory (connected plug-in module) according to figure A.1 (a). Step 3: Fit and press the accessory to be installed as indicated in figure A.1 (b) and then assemble the front cover of the inverter. Step 4: Power up the inverter and check if parameter P0027 shows value 8 (P0027 = 8). If this information is not true, check if the module used is actually the CFW500- CPDP or CFW500-CPDP2 and repeat steps 1-4. 5 SETTINGS The control connections (analogical input / output, digital inputs / outputs and RS485 interface) must be performed as shown in table 1 for the CFW500-CPDP Module or in table 2 for the CFW500-CPDP2 Module. 6 CFW500

PROFIBUS DP Communication Plug-in Module Top Connection Bottom Connection Table 1: Signals of control connector - CFW500-CPDP module Connector 1 DI1 Digital input 1 3 DI2 Digital input 2 Description 5 +24 V +24 Vdc power supply 7 DO1-RL-NO Digital output 1 (NO contact of relay 1) 9 DO1-RL-C Digital output 1 (common point of relay 1) 11 DO1-RL-NC Digital output 1 (NC contact of relay 1) 2 AO1 Analogical output 1 4 AI1 Analogical input 1 6 DO2-TR Digital output 2 (Transistor) 8 RS485 A (-) RS485 (Terminal A- ) 10 RS485 B (+) RS485 (Terminal B+ ) 12 Reference 0 V English Table 2: Signals of control connector - CFW500-CPDP2 module Top Connection Bottom Connection Connector Description 1 DI1 Digital input 1 3 DI2 Digital input 2 5 +24 V +24 Vdc power supply 7 DO1-RL-NO Digital output 1 (NO contact of relay 1) 9 DO1-RL-C Digital output 1 (common point of relay 1) 11 DO1-RL-NC Digital output 1 (Contato NC do Relé 1) 13 A- RxD/TxD negative (green) 15 B+ RxD/TxD positive (red) 2 AO1 Analogical output 1 4 AI1 Analogical input 1 6 DO2-TR Digital output 2 (Transistor) 8 RS485 A (-) RS485 (Terminal A- ) 10 RS485 B (+) RS485 (Terminal B+ ) 12 Reference 0 V 14 Reference 0 V 16 SHIELD Profibus DP cable shield CFW500 7

PROFIBUS DP Communication Plug-in Module English DI1 DI2 RS485 - A RS485 - B +24 V DO1-RL-NO rpm AO1 AI1 DO2-TR R DO1-RL-C DO1-RL-NC +24 V (a) Signals of the control connector for CFW500-CPDP module 8 CFW500

PROFIBUS DP Communication Plug-in Module DI1 DI2 English RS485 - A RS485 - B SHIELD +24 V rpm AO1 AI1 DO2-TR R DO1-RL-NO DO1-RL-C DO1-RL-NC A- B+ +24 V (b) Signals of the control connector for CFW500-CPDP2 module Figure 1: (a) and (b) Signals of the control connector Table 3: Signals of the PROFIBUS DP communication connector - available in CFW500-CPDP module DB-9 1 N.C 2 N.C 3 B (+) 4 RTS 5 6 + 5 V 7 N.C 8 A (-) 9 N.C RTS B+ N.C N.C N.C A- N.C +5 V CFW500 9

PROFIBUS DP Communication Plug-in Module English The location of the DIP-switches to select the kind of the analog input and output signal and the termination of the RS485 and PROFIBUS DP network can be better viewed in figure A.2. To use the analog inputs and/or outputs with signal in current, switch S1 and related parameters must be set as indicated in table 4. For further details about the control connections see chapter 3 Installation and Connection of the CFW500 user's manual. Table 4: Configurations of the switches to select the kind of signal at the analog input and output on the CFW500-CPDP / CFW500-CPDP2 Input/ Output Signal Setting of Switch S1 Range of Signal Parameter Settings Voltage S1.1 = OFF 0...10 V P0233 = 0 or 2 AI1 0...20 ma P0233 = 0 or 2 Current S1.1 = ON 4...20 ma P0233 = 1 or 3 Voltage S1.2 = ON 0...10 V P0253 = 0 or 3 AO1 0...20 ma P0253 = 1 or 4 Current S1.2 = OFF 4...20 ma P0253 = 2 or 5 Table 5: Configurations of the switches for RS485 and PROFIBUS DP communication Communication Switch Switch Setting S1.3 = OFF and RS485 S1 (*) S1.4 = OFF PROFIBUS DP S2 (*) S1.3 = ON and S1.4 = ON S2.1 = OFF and S2.2 = OFF S2.1 = ON and S2.2 = ON Option RS485 termination OFF RS485 termination ON PROFIBUS DP termination resistor inactive PROFIBUS DP termination resistor active (*) No other combinations of the switches are allowed. This module has a connector (figure A.2) used by the CFW500-MMF Flash Memory Module, which allows data transfer between inverters. For further details on this accessory, refer to the installation and operation guide of the CFW500-MMF. 10 CFW500

Módulo Plug-in de Comunicación PROFIBUS DP 1 INFORMACIONES DE SEGURIDAD 1.1 AVISOS DE SEGURIDAD NOTA! Solamente utilizar el módulo plug-in de comunicación PROFIBUS DP (CFW500-CPDP o CFW500-CPDP2) en los convertidores WEG línea CFW500. Se recomienda la lectura del manual del usuario del CFW500 y del manual del usuario del PROFIBUS DP antes de instalar u operar este accesorio. El contenido de esta guía fornece informaciones importantes para el correcto entendimiento y buen funcionamento de este módulo. 1.2 RECOMENDACIONES PRELIMINARES ATENCIÓN! Siempre desconecte la alimentación general antes de conectar o desconectar los accesorios del convertidor de frecuencia CFW500. Aguarde por lo menos 10 minutos para garantizar la desenergización completa del convertidor. Español 2 INFORMACIONES GENERALES Esta guía orienta en la instalación, configuración y operación del módulo plug-in de comunicación PROFIBUS DP (CFW500-CPDP o CFW500-CPDP2). 3 CONTENIDO DEL EMBALAJE Al recibir el producto, verifique si el embalaje contiene: Accesorio en embalaje antiestático. Guía de instalación, configuración y operación. CFW500 11

Módulo Plug-in de Comunicación PROFIBUS DP 4 INSTALACIÓN DEL ACCESORIO El accesorio es fácilmente instalado o sustituido. Para la correcta instalación del accesorio, ejecute los pasos a seguir: Paso 1: Con el convertidor desenergizado, retire la tapa frontal del mismo (figura A.1 (a)). Paso 2: Retire, si existe, el accesorio (módulo plug-in conectado) conforme la figura A.1 (a). Paso 3: Encaje y presione el accesorio a ser instalado conforme indicado en la figura A.1 (b) y después conecte la tapa frontal del convertidor. Paso 4: Energice el convertidor y verifique si el parámetro P0027 indica el valor 8 (P0027 = 8). En caso de que esa información no sea verdadera, verifique si el módulo utilizado realmente es el CFW500-CPDP o CFW500-CPDP2 y repita los pasos 1-4. Español 5 CONFIGURACIONES Las conexiones de control (entrada/salida analógica, entradas/salidas digitales e interfaz RS485) deben ser hechas en el conector conforme tabla 1 para el módulo CFW500-CPDP o tabla 2 para el módulo CFW500-CPDP2. 12 CFW500

Módulo Plug-in de Comunicación PROFIBUS DP Tabla 1: Señales del conector de control - módulo CFW500-CPDP Borne Superior Borne Inferior Conector Descripción 1 DI1 Entrada digital 1 3 DI2 Entrada digital 2 5 +24 V Fuente +24 Vcc 7 DO1-RL-NO Salida digital 1 (contacto NO del relé 1) 9 DO1-RL-C Salida digital 1 (punto común del relé 1) 11 DO1-RL-NC Salida digital 1 (contacto NC del relé 1) 2 AO1 Salida analógica 1 4 AI1 Entrada analógica 1 6 DO2-TR Salida digital 2 (Transistor) 8 RS485 A (-) RS485 (Terminal A- ) 10 RS485 B (+) RS485 (Terminal B+ ) 12 Referencia 0 V Borne Superior Borne Inferior Tabla 2: Señales del conector de control módulo CFW500-CPDP2 Conector Descripción 1 DI1 Entrada digital 1 3 DI2 Entrada digital 2 5 +24 V Fuente +24 Vcc 7 DO1-RL-NO Salida digital 1 (contacto NO del relé 1) 9 DO1-RL-C Salida digital 1 (punto común del relé 1) 11 DO1-RL-NC Salida digital 1 (contacto NC del relé 1) 13 A- RxD/TxD negativo (verde) 15 B+ RxD/TxD positivo (rojo) 2 AO1 Salida analógica 1 4 AI1 Entrada analógica 1 6 DO2-TR Salida digital 2 (Transistor) 8 RS485 A (-) RS485 (Terminal A- ) 10 RS485 B (+) RS485 (Terminal B+ ) 12 Referencia 0 V 14 Referencia 0 V 16 SHIELD Blindaje del cable Profibus DP Español CFW500 13

Módulo Plug-in de Comunicación PROFIBUS DP DI1 DI2 RS485 - A RS485 - B +24 V DO1-RL-NO DO1-RL-C DO1-RL-NC Español rpm AO1 AI1 DO2-TR R +24 V (a) Señales del conector de control para módulo CFW500-CPDP 14 CFW500

Módulo Plug-in de Comunicación PROFIBUS DP DI1 DI2 RS485 - A RS485 - B SHIELD +24 V rpm AO1 AI1 DO2-TR R DO1-RL-NO DO1-RL-C DO1-RL-NC A- B+ +24 V (b) Señales del conector de control para módulo CFW500-CPDP2 Figura 1: (a) y (b) Señales del conector de control Español Tabla 3: Señales del conector de comunicación PROFIBUS DP - disponible en el módulo CFW500-CPDP DB-9 1 N.C 2 N.C 3 B (+) 4 RTS 5 6 + 5 V 7 N.C 8 A (-) 9 N.C RTS B+ N.C N.C N.C A- N.C +5 V CFW500 15

Módulo Plug-in de Comunicación PROFIBUS DP La localización de las DIP-switches para selección del tipo de señal de la entrada y salida analógica y de la terminación de la red RS485 y PROFIBUS DP pueden ser mejor visualizadas en la figura A.2. Para utilizar las entradas y/u salidas analógicas con señal en corriente, se debe ajustar la llave S1 y los parámetros relacionados conforme tabla 4. Para más detalles sobre las conexiones de control consulte el capítulo 3 Instalación y Conexion del manual del usuario del CFW500. Tabla 4: Configuraciones de las llaves para selección del tipo de señal en la entrada y salida analógica en el CFW500-CPDP / CFW500-CPDP2 Español Entrada/ Salida AI1 AO1 Señal Ajuste de la Rango de Llave S1 la Señal Ajuste de Parámetros Tensión S1.1 = OFF 0...10 V P0233 = 0 o 2 0...20 ma P0233 = 0 o 2 Corriente S1.1 = ON 4...20 ma P0233 = 1 o 3 Tensión S1.2 = ON 0...10 V P0253 = 0 o 3 0...20 ma P0253 = 1 o 4 Corriente S1.2 = OFF 4...20 ma P0253 = 2 o 5 Tabla 5: Configuraciones de las llaves para comunicación RS485 y PROFIBUS DP Comunicación Llave Ajuste de las Llaves S1.3 = OFF y RS485 S1 (*) S1.4 = OFF S1.3 = ON y S1.4 = ON S2.1 = OFF y S2.2 = OFF PROFIBUS DP S2 (*) S2.1 = ON y S2.2 = ON Opción Terminación RS485 apagada Terminación RS485 encendida PROFIBUS DP resistor de terminación inactivo PROFIBUS DP resistor de terminación activo (*) Cualquier otra combinación de las llaves no está permitida. Este módulo posee un conector (figura A.2) para utilización del módulo de memoria flash (CFW500-MMF) para transferencia de datos entre convertidores. Para más detalles sobre este accesorio consulte la guía de instalación, configuración y operación del CFW500-MMF. 16 CFW500

Módulo Plug-in de Comunicação PROFIBUS DP 1 INFORMAÇÕES DE SEGURANÇA 1.1 AVISOS DE SEGURANÇA NOTA! Somente utilizar o módulo plug-in de comunicação PROFIBUS DP (CFW500- CPDP ou CFW500-CPDP2) nos inversores WEG linha CFW500. Recomenda-se a leitura do manual do usuário do CFW500 e do manual do usuário do PROFIBUS DP antes de instalar ou operar esse acessório. O conteúdo deste guia fornece informações importantes para o correto entendimento e bom funcionamento deste módulo. 1.2 RECOMENDAÇÕES PRELIMINARES ATENÇÃO! Sempre desconecte a alimentação geral antes de conectar ou desconectar os acessórios do inversor de frequência CFW500. Aguarde pelo menos 10 minutos para garantir a desenergização completa do inversor. 2 INFORMAÇÕES GERAIS Este guia orienta na instalação, configuração e operação do módulo plug-in de comunicação PROFIBUS DP (CFW500-CPDP ou CFW500-CPDP2). 3 CONTEÚDO DA EMBALAGEM Ao receber o produto, verificar se a embalagem contém: Acessório em embalagem anti-estática. Guia de instalação, configuração e operação. Português CFW500 17

Módulo Plug-in de Comunicação PROFIBUS DP 4 INSTALAÇÃO DO ACESSÓRIO O acessório é facilmente instalado ou substituído. Para sua correta instalação execute os passos a seguir: Passo 1: Com o inversor desenergizado, retire a tampa frontal do Inversor conforme figura A.1 (a). Passo 2: Retire, se houver, o acessório (módulo plug-in conectado) conforme a figura A.1 (a). Passo 3: Encaixe e pressione o acessório a ser instalado conforme indicado na figura A.1 (b) e após conecte a tampa frontal do inversor. Passo 4: Energize o inversor e verifique se o parâmetro P0027 indica o valor 8 (P0027 = 8). Caso essa informação não for verdadeira, verifique se o módulo utilizado realmente é o CFW500-CPDP ou CFW500- CPDP2 e repita os passos 1-4. 5 CONFIGURAÇÕES As conexões de controle (entrada/saída analógica, entradas/saídas digitais e interface RS485) devem ser feitas no conector conforme tabela 1 para o módulo CFW500-CPDP ou tabela 2 para o módulo CFW500- CPDP2. Português 18 CFW500

Módulo Plug-in de Comunicação PROFIBUS DP Tabela 1: Sinais do conector de controle - módulo CFW500-CPDP Borne Superior Borne Inferior Conector Descrição 1 DI1 Entrada digital 1 3 DI2 Entrada digital 2 5 +24 V Fonte +24 Vcc 7 DO1-RL-NO Saída digital 1 (Contato NO do relé 1) 9 DO1-RL-C Saída digital 1 (Ponto comum do relé1) 11 DO1-RL-NC Saída digital 1 (Contato NC do relé 1) 2 AO1 Saída analógica 1 4 AI1 Entrada analógica 1 6 DO2-TR Saída digital 2 (Transistor) 8 RS485 A (-) RS485 (Terminal A- ) 10 RS485 B (+) RS485 (Terminal B+ ) 12 Referência 0 V Tabela 2: Sinais do conector de controle - módulo CFW500-CPDP2 Borne Superior Borne Inferior Conector Descrição 1 DI1 Entrada digital 1 3 DI2 Entrada digital 2 5 +24 V Fonte +24 Vcc 7 DO1-RL-NO Saída digital 1 (Contato NO do relé 1) 9 DO1-RL-C Saída digital 1 (Ponto comum do relé 1) 11 DO1-RL-NC Saída digital 1 (Contato NC do relé 1) 13 A- RxD/TxD negativo (verde) 15 B+ RxD/TxD positivo (vermelho) 2 AO1 Saída analógica 1 4 AI1 Entrada analógica 1 6 DO2-TR Saída digital 2 (Transistor) 8 RS485 A (-) RS485 (Terminal A- ) 10 RS485 B (+) RS485 (Terminal B+ ) 12 Referência 0 V 14 Referência 0 V 16 SHIELD Blindagem do cabo Profibus DP Português CFW500 19

Módulo Plug-in de Comunicação PROFIBUS DP DI1 DI2 RS485 - A RS485 - B +24 V DO1-RL-NO DO1-RL-C rpm AO1 AI1 DO2-TR R DO1-RL-NC +24 V (a) Sinais do conector de controle para módulo CFW500-CPDP Português 20 CFW500

Módulo Plug-in de Comunicação PROFIBUS DP DI1 DI2 RS485 - A RS485 - B SHIELD +24 V rpm AO1 AI1 DO2-TR R DO1-RL-NO DO1-RL-C DO1-RL-NC A- B+ +24 V (b) Sinais do conector de controle para módulo CFW500-CPDP2 Figura 1: (a) e (b) Sinais do conector de controle Tabela 3: Sinais do conector de comunicação PROFIBUS DP - disponível no módulo CFW500-CPDP DB-9 1 N.C 2 N.C 3 B (+) 4 RTS 5 6 + 5 V 7 N.C 8 A (-) 9 N.C RTS B+ N.C N.C N.C A- N.C +5 V Português CFW500 21

Módulo Plug-in de Comunicação PROFIBUS DP A localização das DIP-switches para seleção do tipo de sinal da entrada e saída analógica e da terminação da rede RS485 e PROFIBUS DP podem ser melhor visualizadas na figura A2. Para utilizar as entradas e/ou saídas analógicas com sinal em corrente deve-se ajustar a chave S1 e os parâmetros relacionados conforme tabela 4. Para mais detalhes sobre as conexões de controle consulte o capítulo 3 do manual do usuário do CFW500. Tabela 4: Configurações das chaves para seleção do tipo de sinal na entrada e saída analógica no CFW500-CPDP / CFW500-CPDP2 Entrada/ Saída AI1 AO1 Sinal Ajuste da Chave S1 Faixa do Sinal Ajuste de Parâmetros Tensão S1.1 = OFF 0...10 V P0233 = 0 ou 2 0...20 ma P0233 = 0 ou 2 Corrente S1.1 = ON 4...20 ma P0233 = 1 ou 3 Tensão S1.2 = ON 0...10 V P0253 = 0 ou 3 0...20 ma P0253 = 1 ou 4 Corrente S1.2 = OFF 4...20 ma P0253 = 2 ou 5 Tabela 5: Configuração das chaves para comunicação RS485 e PROFIBUS DP Comunicação Chave Ajuste das Chaves S1.3 = OFF e RS485 S1 (*) S1.4 = OFF S1.3 = ON e S1.4 = ON S2.1 = OFF e PROFIBUS DP S2 (*) S2.2 = OFF S2.1 = ON e S2.2 = ON Opção Terminação RS485 desligada Terminação RS485 ligada PROFIBUS DP resistor de terminação inativo PROFIBUS DP resistor de terminação ativo (*) Qualquer outra combinação das chaves não é permitida. Este módulo possui um conector (figura A.2) para utilização do módulo de memória flash (CFW500-MMF) para transferência de dados entre inversores. Para mais detalhes sobre esse acessório consulte o guia de instalação, configuração e operação do CFW500-MMF. Português 22 CFW500

APPENDIX A FIGURES ANEXO A FIGURAS Appendix A - Anexo A (a) Removal of front cover and accessory (a) Remoción de la tapa frontal y del accesorio (a) Remoção da tampa frontal e do acessório (b) Accessory connection (b) Conexión del accesorio (b) Conexão de acessório Figure A.1 (a) to (b): Installation of accessory Figura A.1 (a) a (b): Instalación del accesorio Figura A.1 (a) a (b): Instalação do acessório CFW500 23

Appendix A - Anexo A 1 2 3 4 1 2 S1 AI1 AO1 B+ A- ON DIP ON PROFIBUS DP 62.2 [2.45] 68.5 [2.7] 22.6 [0.9] Figure A.2: CPDP dimensions in mm [in], DIP-switches location and MCard connector Figura A.2: Dimensiones del CPDP en mm [in], localización de las DIP-switches y conectador de MCard Figura A.2: Dimensões do CPDP em mm [in], localização das DIP-switches e conector do MCard 24 CFW500

Appendix A - Anexo A 1 2 3 4 1 2 S1 AI1 AO1 B+ A- ON DIP ON PROFIBUS DP 62.2 [2.45] 68.5 [2.7] 22.6 [0.9] Figure A.3: CPDP2 dimensions in mm [in], DIP-switches location and MCard connector Figura A.3: Dimensiones del CPDP2 en mm [in], localización de las DIP-switches y conectador de MCard Figura A.3: Dimensões do CPDP2 em mm [in], localização das DIP-switches e conector do MCard CFW500 25

NOTES / NOTAS / ANOTAÇÕES

WEG Drives & Controls - Automação LTDA. Jaraguá do Sul - SC - Brazil Phone 55 (47) 3276-4000 - Fax 55 (47) 3276-4020 São Paulo - SP - Brazil Phone 55 (11) 5053-2300 - Fax 55 (11) 5052-4212 automacao@weg.net www.weg.net 11770665 Document: 10002094952 / 02