CORREÇÃO DO FATOR DE POTÊNCIA POWER FACTOR CORRECTION UNITS
ÍNDICE INDEX SISTEMAS AUTOMÁTICOS C. F. P. // 1 / 2 / 3 SISTEMAS TIPO 1 // 4 / 5 SISTEMAS TIPO 2 // 6 / 7 SISTEMAS TIPO 3 // 8 / 9 SISTEMAS TIPO 4 // 10 / 11 P. F. C. AUTOMATIC SYSTEMS // 1 / 2 / 3 TYPE 1 UNITS // 4 / 5 TYPE 2 UNITS // 6 / 7 TYPE 3 UNITS // 8 / 9 TYPE 4 UNITS // 10 / 11
CORREÇÃO DO FATOR DE POTÊNCIA POWER FACTOR CORRECTION UNITS MODELO TIPO 1 Dimensões (h) 600 x (l) 450 x (p) 260mm TYPE 1 MODEL Dimensions (h) 600 x (w) 450 x (d) 260mm MODELO TIPO 2 Dimensões (h) 850 x (l) 650 x (p) 260mm TYPE 2 MODEL Dimensions (h) 850 x (w) 650 x (d) 260mm MODELO TIPO 3 Dimensões (h) 1150x (l) 700 x (p) 360mm TYPE 3 MODEL Dimensions (h) 1150 x (w) 700 x (d) 360mm MODELO TIPO 4 Dimensões (h) 1910 x (l) 1100 x (p) 360mm TYPE 4 MODEL Dimensions (h) 1910 x (w) 1100 x (d) 360mm 1
2
CORREÇÃO DO FATOR DE POTÊNCIA // POWER FACTOR CORRECTION UNITS P. F. C. AUTOMATIC SYSTEMS TECHNICAL DATA Rated Voltage 440 Vac // Maximum overvoltage 1,1 Un // Maximum overcurrent 1,3 In Rated Power 15 420 kvar Rated Frequency 50 60 Hz Rated Power Referred to rated voltage and frequency. Auxiliary Circuits Voltage 400 Vac Regulator Varmetric measurents by means of a CT, with 5A secondary (CT not supplied). Isolating main Switch RP1 models, by three-pole circuit breaker // Other models by three-pole isolator switch with door interlocking block. Wiring The internal cables are self-extinguishing N07VK CEI 20-22 type. The auxiliary circuits are identified according to the electrical drawings. Cabinet Metallic for wall and/or floor installation. Modular in 15mm sheet-metal protected against corrosion by phosphating treatment. Epossidic dust painted (RAL 7035 color) Front door with locking system. Other colors by request. User Manual support behind the door. Protection Degree IP21 open door // IP31 closed door// IK 08 Ventilation Natural (or forced by request, and depending of the environmental conditions). Installation Indoor Montage Wall or Floor. Operating Temperature Range -20 / +50 ºC Cable entrances By the cabinet top when wall mounted in the RP1/ RP2/ and RP3 models. By the footer when floor mounted in the RP2/ RP3/ and RP4 models. Contactors Each bank of capacitors is controlled by specific threepole contactors, for capacitive loads. To limit the inrush current peaks, each contactor is equipped with insertion resistors. Rated voltage of the auxiliary circuits 400Vac, 50Hz. Protections Each bank of capacitors is protected by a 3P magnetothermal circuit breaker (RP1 and RP2 models), or by a set of three-pole fuses NH00 type with high breaking capacity. The auxiliary circuits are also protected by 10x38 fuses. Capacitors LIFASE brand, POLIMET type, cylindrical, three-phase capacitors, self-healing metalized polypropylene film according to the CEI standards, equipped with overpressure device and discharge resistor. Capacitance tolerance -5% to +10% Dielectric losses < 0,4 W/kVar REFERENCE STANDARDS Capacitors CEI EN 60831-1/2; IEC 831-1/2 LV Directive 73/23 EEC (93/68) Equipment CEI EN 60439-81; IEC 439-1 // CIS EN 61921-1 OTHER OPTIONS (BY REQUEST) Protection degree For IP40 to IP54 Protections Protection and control instruments against overvoltage and overcurrent due to harmonic distortions. Note: Other models, different features, level of tension and frequencies available by request. ReativaPlus reserves the right to modify the above-mentioned features and dimensions without previous notice. 3
4 MODELOS TIPO 1 // TYPE 1 MODELS
CORREÇÃO DO FATOR DE POTÊNCIA // POWER FACTOR CORRECTION UNITS MODELOS TIPO 1 // TYPE 1 MODELS PREÇOS SOB CONSULTA. PRICES ON REQUEST. Model Switching steps Rated Current In (A) Rated Voltage (V) Power (kvar)/440 V 50Hz Power banks (kvar) 440 V Power (kvar)/ 400 V 50Hz Cabinet Dim h x w x d mm Power Feed cable (mm2) Main Switch by MCB (A) Regulator Type 5
6 MODELOS TIPO 2 // TYPE 2 MODELS
CORREÇÃO DO FATOR DE POTÊNCIA // POWER FACTOR CORRECTION UNITS MODELOS TIPO 2 // TYPE 2 MODELS PREÇOS SOB CONSULTA. PRICES ON REQUEST. Model Switching steps Rated Current In (A) Rated Voltage (V) Power (kvar)/440 V 50Hz Power banks (kvar) 440 V Power (kvar)/ 400 V 50Hz Cabinet Dim h x w x d mm Power Feed cable (mm2) Main Switch (A) Regulator Type 7
8 MODELOS TIPO 3 // TYPE 3 MODELS
CORREÇÃO DO FATOR DE POTÊNCIA // POWER FACTOR CORRECTION UNITS MODELOS TIPO 3 // TYPE 3 MODELS PREÇOS SOB CONSULTA. PRICES ON REQUEST. Model Switching steps Rated Current In (A) Rated Voltage (V) Power (kvar)/440 V 50Hz Power banks (kvar) 440 V Power (kvar)/ 400 V 50Hz Cabinet Dim h x w x d mm Power Feed cable (mm2) Main Switch (A) Regulator Type * Dimensions without footer footer H = 150mm NOTE: the unit equipped with footer has an extra cost of more 80 9
10 MODELOS TIPO 4 // TYPE 4 MODELS
CORREÇÃO DO FATOR DE POTÊNCIA // POWER FACTOR CORRECTION UNITS MODELOS TIPO 4 // TYPE 4 MODELS DCRL5 DCRL5 DCRL5 DCRL5 DCRL5 DCRL5 DCRL5 DCRK12 DCRK12 DCRJ12 PREÇOS SOB CONSULTA. PRICES ON REQUEST. Model Rated Current In (A) Rated Voltage (V) Power (kvar)/440 V 50Hz Power (kvar)/ 400 V 50Hz Power banks (kvar) 440 V Switching steps Cabinet Dim h x w x d mm Main Switch (A) Regulator Type Cable (mm2) NOTE: At request: higher powers, other models or different features. 11
NOTAS // NOTES A Reativa Plus reserva o direito de alterar os preços constantes da presente tabela. November, 2014 Aos preços indicados acresce o Imposto sobre o Valor Acrescentado (I.V.A.) à taxa legal em vigor. OS produtos e materiais apresentados neste documento são suscetíveis de evolução, tanto nos planos da técnica e da estética, como no plano da utilização. A sua descrição não pode, em caso algum, ser considerada como tendo um aspeto contratual. Assim, só nos responsabilizamos pelas informações dadas após confirmação pelos nossos serviços, Reativa Plus reserves the right to change prices presented in this table. Prices exclude VAT. Statutory rate in force is to be added to all presented prices. Products and materials presented in this document are prone to evolution, both on technical and aesthetics, and operation plans. Its description can not be considered, at any case, as of having a contractual aspect. Therefore Reativa Plus is only liable for the information provided after confirmation by our services. 12
Já verificou a fatura de energia? Paga Energia Reativa? Have you checked your energy bill? Do you pay for Reactive Power? kvar ENERGIA REATIVA Reactive Power (kvar) ENERGIA TOTAL Total Power (kva) ENERGIA ATIVA Active Power (kw) Energia Ativa / Active Power Energia Reativa / Reactive Power TRANSFORMADOR Transformer BATERIA DE CONDENSADOR Capacitor bank CONSULTE-NOS. TEMOS A SOLUÇÃO! CONTACT US. WE HAVE THE SOLUTION! EQUIPAMENTOS DA INSTALAÇÃO Plant Equipments
DISTRIBUIDOR // DISTRIBUTOR