Operação de Instalações Marítimas



Documentos relacionados
Operação de Instalações Marítimas

Manual de instruções para Caixa Coletora Johnson Pump

ICS-GT INTEGRATED CONTROL SYSTEM FOR GAS TURBINE

1 WC System. Instrução Técnica Instrucción Técnica Technical Instruction

Nome empresa: Criado por: Telefone:

DEPARTAMENTO DE ENGENHARIA CIVIL E ARQUITETURA

CERTIFICADO DE GERENCIAMENTO DA SEGURANÇA

Torre Purificadora de Ar MCP-

REFR. VENT. DISPLAY ON OPEN WELL UNITS

SIMPLY 5T 10T 14T SUPER CONGELADOR BLAST CHILLERS / SHOCK FREEZERS. Tramontina

Miniature Solenoid Valve Type 200

Instructions AK-PC 351

Instructions AK-PC 551

Manual de instruções para Sifões VETUS e Johnson Pump

Instructions AK-PC 651

Economia de Energia com recursos de Conversores de Frequência VLT AQUADrive

Uma empresa do grupo:

NPT Active 670 LT DUAL TEMPERATURE REFRIGERATORS ZANUSSI RANGE COMPOSITION FUNCTIONAL AND CONSTRUCTION FEATURES

WATER MATTRESS MASSAGE SYSTEM 20439

IN RE: GUARDIAN ADVOCATE OF/ REF: CURATELA ESPECIAL DE

MANUAL DE INSTRUÇÃO DO COMPRESSOR /COMPRESSOR INSTRUCTION MANUAL MARCA/BRAND GMCC MODELO/MODEL PH310G2C-3KUU

TEMPER. GLASS TOP HOT UNITS - BRIDGE

Balanço de massa Regime transiente

PEI (FPSO Cidade de São Mateus) Plano de Emergência Individual para Incidentes de Poluição por Óleo

Versão: 1.0. Segue abaixo, os passos para o processo de publicação de artigos que envolvem as etapas de Usuário/Autor. Figura 1 Creating new user.

MANUAL DE INSTRUÇÃO DO COMPRESSOR /COMPRESSOR INSTRUCTION MANUAL MARCA/BRAND GMCC MODELO/MODEL PA291X3CS-3MTU

Solutions. Adição de Ingredientes. TC=0.5m TC=2m TC=1m TC=3m TC=10m. O Tempo de Ciclo do Processo é determinado pelo TC da operação mais lenta.

BLOWERS AND COMPRESSORS FOR BIOGAS, LANDFILL AND NATURAL GAS, in conformity with 94/9/EC Directive (ATEX)

DEPARTAMENTO DE ENGENHARIA CIVIL E ARQUITETURA

Depósitos de Óleo Oil Tanks

Welcome to Lesson A of Story Time for Portuguese

NORMAS PARA AUTORES. As normas a seguir descritas não dispensam a leitura do Regulamento da Revista Portuguesa de Marketing, disponível em

75, 8.º DTO LISBOA

HYDRAULIC PRESSES OMECO INDÚSTRIA & COMÉRCIO DE MÁQUINAS LTDA

COMITÊ DO ESPECTRO PARA RADIODIFUSÃO - CER SPECTRUM DAY A REVISÃO DA REGULAMENTAÇÃO DO USO DA FAIXA DE 3,5 GHZ UMA NECESSIDADE COMPROVADA.

User Guide Manual de Utilizador

Energia e Sustentabilidade A Eficiência Energética na Indústria

Da Emoção à Lesão: um Guia de Medicina Psicossomática (Portuguese Edition)

NORMAS DE FUNCIONAMENTO DOS CURSOS DE LÍNGUAS (TURMAS REGULARES E INTENSIVAS) 2015/2016

VGM. VGM information. ALIANÇA VGM WEB PORTAL USER GUIDE June 2016

Aquecimento de Combustível, uma forma simples de reduzir emissões veiculares

REFRIGERADOR 1400 LT REFRIGERATED CABINETS 700 LT

Pinça pneumática angular de auto-centragem com 2 mordentes série AA-25-NO. 2-jaw self-centering angular pneumatic gripper series AA-25-NO

REFRIGERADOR 700 LT REFRIGERATED CABINETS 700 LT

GEAR PUMPS RECOMMENDATIONS BEFORE START-UP

Sistema de Reciclagem da Água dos Restos de Concreto

Modelagem e Simulação de Incêndios. Fire dynamics. Carlos André Vaz Junior

DATE July 04 th and 05 th, VENUE Ginásio Gilberto Cardoso Maracanãzinho Rua Professor Eurico Rabelo, S/Nr. Rio de Janeiro/RJ Brasil

Farmacologia na Pratica de Enfermagem (Em Portuguese do Brasil)

FLOW Design by STUDIOP

DUTOPLAST DO BRASIL INDÚSTRIA DE PLÁSTICOS LTDA.

UNIDADE DE PESQUISA CLÍNICA Centro de Medicina Reprodutiva Dr Carlos Isaia Filho Ltda. SAMPLE SIZE DETERMINATION FOR CLINICAL RESEARCH

SONDA DE ÁGUA QUENTE SANITÁRIA

Regulador Integrado TA Rev.0. Regulador Integrado TA-956 Integrated Regulator TA-956

Biscuit - potes (Coleção Artesanato) (Portuguese Edition)

Clara dos Anjos (Portuguese Edition)

Tabela de erros máquinas Gree a R410a

Desumidificador de ar

i. Modelo Heskestad ii. Modelo Delichatsios


CERTIFICADO INTERNACIONAL DE BORDA LIVRE

Kit de Controlo PAC-IF031B-E

A ENTREVISTA COMPREENSIVA: UM GUIA PARA PESQUISA DE CAMPO (PORTUGUESE EDITION) BY JEAN-CLAUDE KAUFMANN

TUTTOPIZZA DEEP

Serviços: API REST. URL - Recurso

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education

PROCESSO DE VENDA DE PROJETO DE REMEDIAÇÃO OBRIGAÇÕES/LIMITAÇÕES. Ana Paula Queiroz Waterloo Brasil Ltda.

Filtros de Areia Aster Confiança na filtragem da sua piscina. Aster sand filters Reliable filtration for your pool

Motor PTC Kit. Kit PTC del Motor. Kit PTC do Motor SSW-07 / SSW-08

Efficient Locally Trackable Deduplication in Replicated Systems. technology from seed

ACTIVESELF BAIN-MARIE UNITS - DRY HEATING ZANUSSI RANGE COMPOSITION FUNCTIONAL AND CONSTRUCTION FEATURES


LIGHT PANEL CONTENTS Light Panel Power supply Fixtures (brackets, screws)

Como testar componentes eletrônicos - volume 1 (Portuguese Edition)

daily activity into three 10-minute segments if you re having difficulty finding time to exercise.

ELITE PA TN. Tramontina BANCADA REFRIGERADA ELITE CONFEITARIA - VENTILADA TN ELITE REFRIGERATED COUNTERS FOR PASTRY - VENTILATED TN

Espionagem e Vigilância Eletrônica (Portuguese Edition)

Fundamentos Básicos e Avançados de SEO (Portuguese Edition)

Transcrição:

ENIDH, Outubro 2013

Sumário 1 Fresh Water Hydrophore System 2 Refrigeration System 3 Bilge System

1 Fresh Water Hydrophore System 2 Refrigeration System 3 Bilge System

Fresh Water Hydrophore System

Fresh Water Hydrophore System Fresh Water Hydrophore System consists of: a pressurized hydrophore tank with necessary pumps and valves; a drinking water tank; and a fresh water heater. The capacity of the system is approx. 10 t/h of cold water, hot water and drinking water; The hydrophore tank volum is 3 m 3 and pressure is kept between 3 and 4 bar.

1 Fresh Water Hydrophore System 2 Refrigeration System 3 Bilge System

Refrigeration System

Refrigeration System The refrigeration plant consists of the main components: Electrically driven 50kW screw compressor; Compressor lubrication oil recovery system; Sea water cooled condenser; Refrigerant liquid receiver; The plant comprises following compartments: Meat/Fish compartment (-18 C) including: One 4 kw air fan for cooling down; One 1.5 kw air fan for normal operation; One evaporator with dry expansion; Evaporator electrical defrost device; Provision store for perishable goods (+5 C) including: One air fan; One evaporator with dry expansion; One evaporator pressure controller.

Refrigeration System Description The compressor is lubricated and cooled by oil and refrigerant gases; The lubrication oil is separated from the compressed refrigerant gas in the oil separator; If the oil level is less than 20% of full, new oil must be added; A substantial part of the compressor heat is transferred to the cooling oil in the compressor screw, and the oil must be cooled; The sea water flow to the condenser is supplied by two pumps. Normally just one is in operation, while the other is standby. The condensed refrigerant flows by gravity to the receiver; The valve called vapour valve is for pressure equalising between condenser and the liquid receiver vessel; The temperature of the Meat/Fish store is regulated by the compressor load while the Provision store temperature is set by the position of the evaporator pressure regulator valve.

Refrigeration System Operation Preparation: Line up valves in the lubrication oil system and start the pump; Check and if necessary, refill the lubrication oil by means of the make-up pump; Open vapour and liquid valves between condenser and receiver; Open sea water cooling valves to lubrication oil cooler and condenser and start sea water pump; Condenser cooling water control valve must be set to a suitable opening to maintain appropriate condensation pressure.

Refrigeration System Operation Starting: Open the liquid valves from receiver to evaporators; Start air fans in compartments; Reset the trip functions, if any present, and start the compressor; Set temperature control into MAN and adjust capacity control slide valve to 10% (otherwise compressor will trip on overload); Gradually increase compressor capacity manually checking the compressor electric power consumption during cooling down; Set temperature controller into AUTO when temperature in Meat/Fish store is below 10 C; Normal temperature in Meat/Fish store is 18 C; When Meat/Fish store temperature approaches 18 C change to 1.5 kw fan; Adjust Provision store evap. capacity regulator to maintain Provision store temperature at 5 C.

1 Fresh Water Hydrophore System 2 Refrigeration System 3 Bilge System

Bilge Regulations To reduce pollution of the world s coasts and waters by the shipping industry, a great number of laws, regulations and penalties have been established and are being enforced; These include regulations set by: International Convention for the Prevention of Pollution from Ships, 1973, as modified by the Protocol of 1978 (MARPOL 73/78 Annex I); Federal Water Pollution Control Act of 1970 (FWPCA); Oil Pollution Act of 1990 (OPA 90). Of greatest interest aboard the training ship are the regulations concerning the pumping of machinery space bilge.

Bilge General Regulation As established by MARPOL 73/78 rule 9:... any discharge into the sea of oil or oily mixtures from ships to which this Annex applies shall be prohibited except where all the following conditions are satisfied:... from a ship of 400 gross tonnage and above: the ship is not within a special area; the ship is proceeding en route; the oil content of the effluent does not exceed 15 parts per million (ppm); the ship has in operation equipment as required by Regulation 16 (requirements of the oil content monitor, oil separating or filtering device).

Oil Record Book The following operations must be recorded in the oil record book: Ballasting or cleaning of oil fuel tanks; Discharge of dirty ballast or cleaning water from oil fuel tanks; Collection and disposal of oil residues (sludge); Automatic and Non-automatic discharge overboard or disposal otherwise of bilge water which has accumulated in machinery spaces; Condition of oil discharge monitoring and control system (failures and repairs); Accidental or other exceptional discharge of oil; Bunkering of fuel or bulk lubricating oil;...

Bilge System Description The following engine room bilge wells are included: Aft Port Stbd Fwd A sludge tank and an incinerator are also included:

Bilge Wells/Incinerator

Incinerator Operation Operation: Note amount of oil in sludge tank; Open valve from sludge tank to burner pump; Open valve to incinerator; Start incinerator by pushing flame ON; Incinerator will automatically stop at low level in sludge tank; Note and record amount of sludge incinerated; Stop pump and close valves.

Bilge Separator System

Bilge Separator

Preparation: Bilge Separator Preparation Start electric heating and set separator operation in MANUAL; Set the separator into AUTO mode when sufficient temperature (50 C); Check the setting of the ppm detector. Separator operation in AUTO mode: The overboard intermediate valve is closed and the re-circulation valve opened if the ppm limit in the overboard water is above a pre-set limit; When the oil/water interface sensor detects low level (much oil), the sludge valve is opened; The bilge separator pump may be started/stopped automatically according to the bilge well level (dependent on suction from the engine room bilge well). If the bilge pump is ON for more than 20% (adjustable) of the OFF time an alarm is activated.

Daily Bilge Services Check level and oil content in bilge well; Open suction valve from bilge well; Open valves through separator; Check that over board valve is closed; Open discharge valve to Clean Bilge Tank ; Check that bilge separator is in AUTO; Start bilge pump in manual; If bilge has high oil content: Open 3-way valve before bilge separator and discharge directly to sludge tank; Let the oily water mixture separate in sludge tank before emptying water to clean bilge tank.

Emptying Clean Bilge Tank Check and record tank level, time and ship s position; Check that bilge separator is ready; Open suction valve from clean bilge tank; Open discharge over board; Check that bilge separator is in AUTO; Start bilge pump; Observe PPM-meter to avoid pumping oil overboard; Check and note tank level, time and ship s position when finished.

Stopping Bilge Separator Ensure operation in MANUAL mode; Close bilge suction valve and open sea suction to flush separator; Manually open sludge valve to remove recovered oil; Stop pump and close sea suction and overboard valves.

Sumário 1 Fresh Water Hydrophore System 2 Refrigeration System 3 Bilge System