KuMax (1000 V / 1500 V)
|
|
|
- Anderson Cleyton
- 7 Há anos
- Visualizações:
Transcrição
1 KuMax (1000 V / 1500 V) SUPER HIGH EFFICIENCY POLYGEN4 MODULE CS3U P With Canadian Solar s industry leading black silicon cell technology and the innovative LIC (Low Internal Current) module technology, we are now able to offer our global customers high power poly modules up to 360 W. The KuMax poly modules with a dimension of 2000 ˣ 992 mm, close to our 72 cell MaxPower modules, have the following unique features: Higher power classes for equivalent module sizes High module efficiency up to % LOW hot spot temperature risk LOW temperature coefficient (Pmax): % / C LOW NMOT (Nominal Module Operating Temperature): 43 ± 2 C More power output thanks to Low power loss in cell low NMOT: 43 ± 2 C connection Safer: lower hot spot Heavy snow load up to 5400 Pa, temperature wind load up to 2400 Pa Low BoS cost with 1500 VDC system voltage linear power output warranty product warranty on materials and workmanship PRODUCT CERTIFICATES* IEC / IEC 61730: 2005 & 2016: VDE / CE / UL 1703: CSA * Please contact your local Canadian Solar sales representative for the specific product certificates applicable in your market.
2 ENGINEERING DRAWING (mm) CS3U-355P / I-V CURVES Rear View Frame Cross Section A-A 30 A 10 9 A Φ5 Grounding Hole 8-14x9 Mounting Hole 4-10x7 Mounting Hole(tracker) A A Mounting Hole 2-R V V R W/m W/m 2 5 C 25 C 600 W/m 2 45 C W/m W/m 2 65 C ELECTRICAL DATA STC* CS3U 345P 350P 355P 360P Nominal Max. Power (Pmax) 345 W 350 W 355 W 360 W Opt. Operating Voltage (Vmp) 39.0 V 39.2 V 39.4 V 39.6 V Opt. Operating Current (Imp) 8.86 A 8.94 A 9.02 A 9.10 A Open Circuit Voltage (Voc) 46.4 V 46.6 V 46.8 V 47.0 V Short Circuit Current (Isc) 9.43 A 9.51 A 9.59 A 9.67 A Module Efficiency 17.39% 17.64% 17.89% 18.15% Operating Temperature -40 C ~ +85 C Max. System Voltage 1000 V (IEC / UL) or 1500 V (IEC / UL) Module Fire Performance TYPE 1 (UL 1703) or CLASS C (IEC 61730) Max. Series Fuse Rating 30 A Application Classification Class A Power Tolerance 0 ~ + 5 W * Under Standard Test Conditions (STC) of irradiance of 1000 W/m2, spectrum AM 1.5 and cell temperature of 25 C. MECHANICAL DATA Specification Data Cell Type Poly-crystalline, ˣ mm Cell Arrangement 144 [2 ˣ (12 ˣ 6) ] Dimensions 2000 ˣ 992 ˣ 40 mm (78.7 ˣ 39.1 ˣ 1.57 in) Weight 22.6 kg (49.8 lbs) Front Cover 3.2 mm tempered glass Frame Anodized aluminium alloy, crossbar enhanced J-Box IP68, 3 diodes Cable 4.0 mm² & 12 AWG Cable Length 1670 mm (65.7 in) Connector T4 (IEC / UL) Per Pallet 27 pieces Per Container (40 HQ) 594 pieces ELECTRICAL DATA NMOT* CS3U 345P 350P 355P 360P Nominal Max. Power (Pmax) 255 W 259 W 263 W 266 W Opt. Operating Voltage (Vmp) 35.6 V 35.8 V 36.0 V 36.1 V Opt. Operating Current (Imp) 7.17 A 7.24 A 7.29 A 7.37 A Open Circuit Voltage (Voc) 43.3 V 43.5 V 43.7 V 43.9 V Short Circuit Current (Isc) 7.61 A 7.68 A 7.74 A 7.80 A *Under Nominal Module Operating Temperature (NMOT), irradiance of 800 W/m2, spectrum AM 1.5, ambient temperature 20 C, wind speed 1 m/s. TEMPERATURE CHARACTERISTICS Specification Data Temperature Coefficient (Pmax) % / C Temperature Coefficient (Voc) % / C Temperature Coefficient (Isc) 0.05 % / C Nominal Module Operating Temperature 43±2 C PARTNER SECTION The aforesaid datasheet only provides the general information on Canadian Solar products and, due to the on-going innovation and improvement, please always contact your local Canadian Solar sales representative for the updated information on specifications, key features and certification requirements of Canadian Solar products in your region. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our PV modules. CANADIAN SOLAR (USA) INC. August 2017 All rights reserved PV Module Product Datasheet V5.552_E1_NA 3000 Oak Road, Suite 400, Walnut Creek, CA 94597, USA [email protected]
Catálogo de Produtos. Energia solar
Catálogo de Produtos Energia solar 01/2016 CM TUV NORD CERT GmbH Módulos fotovoltaicos Os módulos fotovoltaicos ReneSola VirtusII são reconhecidos globalmente por sua alta efi ciência, durabilidade e qualidade
Weather-Resistant Louvres
SA3/1/EN/2 Weather-Resistant Louvres for constant volume systems Type WG - AWG - WGE - AWK - WG-F TROX South Africa (Pty) Ltd. 10 Wigford Road Masons Mill Pietermaritzburg Tel. +27 (0)33 398 1006 Fax.
Mobile Communications Product Guide
Part Number Mobile Communications Product Guide Power Management ICs Description Package(s) Available (Lead-free) OZ522 Charger + DC/DC PMU 20 SSOP 23 OZ8071 USB Protection IC and Battery Charger 20 QFN
HIGH SPEED TABLE TOP CENTRIFUGE. Equipment. High Speed HERMLE
HIGH SPEED TABLE TOP CENTRIFUGE Equipment High Speed HERMLE L ABOR T E CHNIK High Speed Table Top Centrifuge Z 36 HK The Z 36 HK is the culmination of many years of centrifuge design experience combined
ENERGIA SOLAR FOTOVOLTAICA
CATÁLOGO ENERGIA SOLAR FOTOVOLTAICA Módulo Monocristalino de 60 Células BSM230M-60 Características Qualidade e dos módulos Todos os módulos solares são montados em Portugal pela Plurigás Solar Energias
Modular Harmonic Mitigation
Energy Ef iciency Power Quality Modular Harmonic Mitigation Solution 1 3 5 7 9 11 + 1 3 5 7 9 11 1 3 5 7 9 11 ~ A B C Uo U U/2 0 -U/2 U wt Uo U U/2 0 -U/2 U wt Uo U U/2 0 -U/2 U wt > > Items Rated input
Test Report (Relatório de testes em laboratório)
Test Report (Relatório de testes em laboratório) Photovoltaic module performance measurement at standard test conditions (STC) (Medição do desempenho de módulos Fotovoltaicos em condições padrão (STC))
MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3
Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the
Test Report (Relatório de testes em laboratório)
Solar/ Fuelcell Technology Test Report (Relatório de testes em laboratório) Photovoltaic module performance measurement at standard test conditions (STC) (Medição do desempenho de módulos Fotovoltaicos
ATS01N232QN PARTIDA SUAVE SOFT START MICROPROCESSADO ICL 32A V
ficha técnica do produto Características ATS01N232QN PARTIDA SUAVE SOFT START MICROPROCESSADO ICL 32A 380-415V Complementar Estilo de montagem Função disponível Limites de tensão de alimentação principal
ABL8RPM24200 fonte chaveada regulada - monofásica ou bifásica V - 24 V - 20 A
ficha técnica do produto Características ABL8RPM24200 fonte chaveada regulada - monofásica ou bifásica - 100..240 V - 24 V - 20 A Complementar Limites da tensão de entrada Frequência da rede Corrente de
Norma técnica de instalações elétricas de arranjos fotovoltaicos: Garantindo a qualidade dos sistemas
Norma técnica de instalações elétricas de arranjos fotovoltaicos: Garantindo a qualidade dos sistemas Marcelo Pinho Almeida Laboratório de Sistemas Fotovoltaicos Instituto de Energia e Ambiente Universidade
Test Report Relatório de testes em laboratório
Page 1 of 19 Performance Measurement at STC of Photovoltaic(PV) Modules Medição do desempenho de módulos Fotovoltaicos em condições padrão (STC) Report No. Relatório Nº. : Date of issue : 06/05/2018 Data
Miniature Solenoid Valve Type 200
2/2-Way, Direct-acting, G1/8 - M5 Advantages/Benefits Normally closed Body materials: brass, stainless steel Short response time Compact design Design/Function Applications is a direct-acting plungertype
Relatório de Ensaios No. < > Rev. <01> Data < > Ensaios de acordo com os requisites acima
Ensaiado no Laboratório TUV SUD CBTL YOT Relatório de Ensaios No. Rev. Data Cliente: Fabricante: Zhejiang ERA solar Technology Co., Ltd. NO.888 huangjiao road (sihai road),
PROJETO DE NORMA NBR PARA INSTALAÇÕES ELÉTRICAS DE SISTEMAS FOTOVOLTAICOS
PROJETO DE NORMA NBR PARA INSTALAÇÕES ELÉTRICAS DE SISTEMAS FOTOVOLTAICOS Marcelo Pinho Almeida Laboratório de Sistemas Fotovoltaicos Instituto de Energia e Ambiente Universidade de São Paulo SISTEMAS
RM4JA32M RELE DE MEDICAO E CONTROLE DE CORRENTE 2NANF A 220A2
ficha técnica do produto Características RM4JA32M RELE DE MEDICAO E CONTROLE DE CORRENTE 2NANF 0.3 15A 220A2 Complementar Tensão de comutação máxima principal Linha de produto Zelio Control Tipo de produto
ENERGIA SOLAR FOTOVOLTAICA MÓDULOS POLICRISTALINOS - SI-ESF-M-P156-60
Solar Innova usa os últimos materiais para a fabricação de seus módulos solar. Nossos módulos são ideais para qualquer aplicativo que usa o efeito fotoelétrico como uma fonte de energia limpa por causa
FM1. Chaves fim de curso / Limit switches. Especificações / Specifications. Acessório / Accessory. linha / type FM 1300 FM 1307 FM 1305 FM 1306
Contatos para 15 A Vários tipos de atuadores Contato de ação rápida Alta precisão Baixo custo FM1 15 A contacts Wide range of actuators Snapaction contact High precision Low cost Tensão de comutação máx/
Mecanismos de qualidade no setor FV
Mecanismos de qualidade no setor FV São Paulo, Agosto 2018 JinkoSolar Co., Ltd. Agenda 1 Visão Geral da Companhia 2 Certificações Módulos FV Presença Global 8 Fábricas 31 Subsidiárias/escritórios 80 +
Normas técnicas e garantia de qualidade dos sistemas fotovoltaicos
Normas técnicas e garantia de qualidade dos sistemas fotovoltaicos Marcelo Pinho Almeida Laboratório de Sistemas Fotovoltaicos Instituto de Energia e Ambiente Universidade de São Paulo PROJETO PRODUÇÃO
www.wattsun-solar.com WATTSUN
SISTEMAS SOLARES www.wattsun-solar.com WATTSUN SISTEMAS S O L A R E S FIX&POWER SISTEMAS S O L A R E S Autoconsumo FIX&POWER Contador SISTEMAS S O L A R E S 3 kw + 2 kw 3 kw Autoconsumo parcial SISTEMAS
Leica Sprinter 50 / 150 / 150M / 250M Push the Button
Leica Sprinter 50 / 150 / 150M / 250M Push the Button Leica Sprinter 50 / 150 Construction Levels Product Offering Sprinter 50 (Standard / US) Art. No. 762628 / 764686 Sprinter 50, 2.0 mm, electronic level
tabela comparativa módulos solares fotovoltaicos
tabela comparativa módulos solares fotovoltaicos A Tabela Comparativa é um documento de consulta fundamental para todos os técnicos e profissionais interessados no tema, apresentando os principais players
ENERGIA SOLAR FOTOVOLTAICA MÓDULOS MONOCRISTALINOS SEM MOLDURA - SI-ESF-M-M125-36
Solar Innova usa os últimos materiais para a fabricação de seus módulos solar. Nossos módulos são ideais para qualquer aplicativo que usa o efeito fotoelétrico como uma fonte de energia limpa por causa
PRODUCT FAMILY DATASHEET SubstiTUBE PURE
SubstiTUBE PURE Economic LED tubes for electromagnetic control gears AREAS OF APPLICATION Corridors, stairways, parking garages Cooling and storage rooms Warehouses Domestic applications General illumination
Módulos Fotovoltaicos
Módulos Fotovoltaicos Os módulos são o principal componente das instalações fotovoltaicas. Estes para além de terem que produzir energia por mais de 25 anos, têm que resistir às mais rigorosas variações
Dropbox Quick Start. What is Dropbox? The Dropbox Folder
Dropbox Quick Start What is Dropbox? Dropbox is a free service that lets you bring all your photos, docs, and videos anywhere. Any file you save to your Dropbox will also automatically save to all your
ABL8WPS24200 fonte alimentação regulada comutada - 380/500V trifásica - 24VCC - 20A - 480W
Características fonte alimentação regulada comutada - 380/500V trifásica - 24VCC - 20A - 480W Principal Linha de PRODUTO Tipo de produto ou componente Tipo de fonte de alimentação Tensão de entrada Tensão
Meditacao da Luz: O Caminho da Simplicidade
Meditacao da Luz: O Caminho da Simplicidade Leonardo Boff Click here if your download doesn"t start automatically Meditacao da Luz: O Caminho da Simplicidade Leonardo Boff Meditacao da Luz: O Caminho da
ENERGIA SOLAR FOTOVOLTAICA MÓDULOS POLICRISTALINOS - SI-ESF-M-BIPV-SM-P156-48
Solar Innova usa os últimos materiais para a fabricação de seus módulos solar. Nossos módulos são ideais para qualquer aplicativo que usa o efeito fotoelétrico como uma fonte de energia limpa por causa
LIGHT PANEL CONTENTS Light Panel Power supply Fixtures (brackets, screws)
Page 1 of 8 LIGHT PANEL 20367 CONTENTS Light Panel Power supply Fixtures (brackets, screws) ABOUT THIS PRODUCT The Light Panel may be used on a table top as a free-standing object, or mounted either horizontally
ENERGIA SOLAR FOTOVOLTAICA MÓDULOS MONOCRISTALINOS - SI-ESF-M-M125-48
Solar Innova usa os últimos materiais para a fabricação de seus módulos solar. Nossos módulos são ideais para qualquer aplicativo que usa o efeito fotoelétrico como uma fonte de energia limpa por causa
User Guide. Wiegand Reader AR-721U/ AR-721K/ AR-661U V060419
User Guide Wiegand Reader AR-72U/ AR-72K/ AR-66U V06049 0 . Main Features Easily integrated with soyal or other access control systems. Programmable various outputs formats Wiegand, magstripe or serial.
GREEN ENERGY. AMRTEC Tecnologia, Importação e Exportação Ltda. PAINEL FOTOVOLTAICO
GREEN ENERGY AMRTEC Tecnologia, Importação e Exportação Ltda. www.amrtec.com.br PAINEL FOTOVOLTAICO LINHAS WS-SLP10.12 e WS-SLP15.12 a empresa A AMRTEC é uma provedora de alta tecnologia e serviços diferenciados
Energia Solar Fotovoltaica
Energia Solar Fotovoltaica Panoramas da indústria fotovoltaica no Brasil Oportunidades e Desafios Wladimir Janousek Canadian Solar Radiografia da Indústria Solar Fotovoltaica no Brasil Indústria local
BERNT LORENTZ GmbH & Co. KG Siebenstücken 24 D Henstedt-Ulzburg
Parâmetro Local: Portugal, (39 Norte; 9 Oeste) Água, temperatura: 25 C Rendimento diário necessário: 25 m³; Dimensionamento para época personalizada Tipo de tubagem: plástico Nível de água estático: Produtos
ABL1REM24062 FONTE DE ALIMENTACAO CHAVEADA 24V6.2A
ficha técnica do produto Características ABL1REM24062 FONTE DE ALIMENTACAO CHAVEADA 24V6.2A 150W Complementar Limites da tensão de entrada Frequência da rede Corrente de irrupção Cos phi 0.65 principal
RUNTAL BRASIL (11) ABL1REM12050 FONTE CHAVEADA 12V5A 60W
ficha técnica do produto Características RUNTAL BRASIL (11) 2626-4645 ABL1REM12050 FONTE CHAVEADA 12V5A 60W principal Linha de produto Phaseo Dedicado Tipo de produto ou componente Fonte de alimentação
User's Guide. Manual de Utilizador
User's Guide Manual de Utilizador USER'S GUIDE HDD/SSD Support: SATA 2.5 (up to 12.5mm height) Material: Aluminium and Plastic External interface: USB 3.0 (compatible with USB 2.0/1.1) Internal interface:
Thank you for using Shepherd 240 Biometric Fingerprint Lock. Please read this Installation Manual carefully before attempting
Preface Thank you for using Shepherd 240 Biometric Fingerprint Lock Please read this Installation Manual carefully before attempting to install your new lock. This manual covers installation procedures
IDE 2.5" hd:basic. hdd enclosure caixa externa para disco rígido
IDE 2.5" hd:basic hdd enclosure caixa externa para disco rígido IDE 2.5" hd:basic USER S GUIDE SPECIFICATONS HDD Support: IDE 2.5 Material: Aluminium Input connections: IDE HDD Output connections: USB
ATLAS DE ACUPUNTURA VETERINáRIA. CãES E GATOS (EM PORTUGUESE DO BRASIL) BY CHOO HYUNG KIM
Read Online and Download Ebook ATLAS DE ACUPUNTURA VETERINáRIA. CãES E GATOS (EM PORTUGUESE DO BRASIL) BY CHOO HYUNG KIM DOWNLOAD EBOOK : ATLAS DE ACUPUNTURA VETERINáRIA. CãES E GATOS Click link bellow
145.04 145.04 145.04 145.04 145.10 145.10 435.11 580.15 435.11 435.11 435.11 435.11 H H,L,M H H H H,L,M 50 50 50 50 7.32/2.83 8.15/3.03 8.19/3.11 0.7+0.13 x n 0.4+0.13 x n 0.4+0.13x n 0.7+0.13 x n 1.1+0.20
Instructions 22" Rotary Unloader Valve Instructions
1004 East Illinois Street Assumption, IL 62510 1-217-226-4421 Instructions 22" Rotary Unloader Valve Instructions Use supplied 3/8" x 1" bolts and 3/8" nuts for boot to bin collar connection. Use rope
Física Experimental VI
Física Experimental VI 4300314 1º Semestre de 2017 Instituto de Física Universidade de São Paulo Professor: Antonio Domingues dos Santos E-mail: [email protected] Fone: 3091.6886 24 de maio Arduino -
TYSON OUTDOOR LIGHTING ILUMINAÇÃO DE EXTERIOR HIGH POWER FLOOD LIGHT PROJETOR DE ALTA POTÊNCIA. Lighting emotions!
HIGH POWER FLOODLIGHT HIGH POWER FLOOD LIGHT OUTDOOR LIGHTING ILUMINAÇÃO DE EXTERIOR HIGH POWER FLOODLIGHT INNOVATIVE PRODUCT PRODUTO INOVADOR Brilumen introduces you the innovative Tyson, a powerful,
Livros Manual Dos Jovens Estressados Augusto Cury READ ONLINE
Livros Manual Dos Jovens Estressados Augusto Cury READ ONLINE If you are searching for a ebook Livros manual dos jovens estressados augusto cury in pdf form, in that case you come on to loyal site. We
MEDIÇÃO DA CORRENTE ELÉCTRICA COM SENSOR DE EFEITO HALL
TRABALHO 1 MEDIÇÃO DA CORRENTE ELÉCTRICA COM SENSOR DE EFEITO HALL DESCRIÇÃO DO TRABALHO Pretende se medir a corrente eléctrica (DC) que atravessa um condutor de forma indirecta. A figura que se segue
Siemens AG 2009 SIRIUS SENTRON SIVACON. Catálogo LV 90 2009. Baixa Tensão Corte, protecção e comando. Answers for industry.
SIRIUS SENTRON SIVACON Catálogo LV 90 2009 Baixa Tensão Corte, protecção e comando Answers for industry. Interruptores de corte em carga, sistemas de barramentos SENTRON 8US Introdução Apresentação geral
Primavera Risk Analysis v8.7
PRIMAVERA RISK ANALYSIS Primavera Risk Analysis v8.7 Installation Manual Primavera Risk Analysis Development v1.10 - Aug 2012 This document will provide the necessary information for you to install Primavera
Detecção de gás da Danfoss Módulo de expansão
Ficha técnica Detecção de gás da Módulo de expansão O módulo de Expansão do controlador de detecção de gás é utilizado para expansão da cobertura do cabo em termos de número de ciclos de fieldbus e o comprimento
DALI TECHNOLOGY. Sistemas e Planeamento Industrial DOMÓTICA. Eng.º Domingos Salvador dos Santos.
Sistemas e Planeamento Industrial DOMÓTICA DALI TECHNOLOGY Eng.º Domingos Salvador dos Santos email:[email protected] October 2017 Table of Contents DALI System DALI Field Devices DALI Controllers Topologies
hdd enclosure caixa externa para disco rígido
hdd enclosure caixa externa para disco rígido USER S GUIDE SPECIFICATONS HDD Support: SATA 2.5 Material: Aluminium and plastics Input connections: SATA HDD Output connections: USB 3.0 (up to 5.0Gbps)
Geradores 3,3 kwp e 4,95 kwp
Geradores 3,3 kwp e 4,95 kwp Geradores padrão monofásicos On Grid Práticos, tecnológicos e com monitoramento via Wi-Fi, nossos geradores possuem estrutura para qualquer tipo de telhado. Gerador 3,3 kwp
Motores Automação Energia Transmissão & Distribuição Tintas. Automação Contatores para Manobra de Capacitores
Motores Automação Energia Transmissão & Distribuição Tintas Automação Contatores para Manobra de Capacitores Manobras de Capacitores para Correção do Fator de Potência A linha de contatores especiais CWMC
Presentation 2017/18
Presentation 07/8 PHARMACEUTICAL BRAZILIAN MARKET COMPANIES DISTRIBUTION Brazilian States Number of Companies São Paulo - SP 87 Rio de Janeiro - RJ 6 Minas Gerais - MG 48 Goias - GO 4 Paraná - PR 9 Others
Manual de montagem do KIT 5E1
www.altanatubes.com Manual de montagem do KIT 5E1 Partes do seu kit Parabéns por adquirir o KIT 5E1 da Altana Tubes. Com ele você terá não apenas prazer de montar o seu próprio amplificadro, como a certeza
GEAR PUMPS RECOMMENDATIONS BEFORE START-UP
GEAR PUMPS RECOMMENDATIONS BEFORE START-UP CTI Gear pumps recommendations before start-up 0811-0 Attention: The application of ABER gear pumps must follow all the instructions hereby mentioned in order
Manual de instruções para Caixa Coletora Johnson Pump
Manual de instruções para Caixa Coletora Johnson Pump Em caso dúvidas na instalação após a leitura do manual, favor entrar em contato com nosso departamento técnico através do telefone: (11) 3477-5655
AX-M Series. - MPPT* Controlador Solar - 800, 1600, 2400, 3200, 4000W de potência nominal - 24 / 48VDC. AX-P Series
Inversores Solares AX-Series - 5kVA Inversor Multifuncional Novo - Inversor PV - PV / Carregador de bateria com 3 fases de carga - Fonte de alimentação: bateria - Inversor de onda senoidal com função de
ANEXO. MANUAL DE INSTALAÇÃO DO MÓDULO SOLAR PADRÃO. Apenas para uso profissional
ANEXO. MANUAL DE INSTALAÇÃO DO MÓDULO SOLAR PADRÃO Apenas para uso profissional ANEXO A: MÉTODOS DE MONTAGEM ALTERNATIVA MÉTODO DE MONTAGEM A: BRAÇADEIRA MÉTODO DE MONTAGEM B: SISTEMAS DE INSERÇÃO 3 3
Advanced machines and tools for the production of ladders and stepladders
Advanced machines and tools for the production of ladders and stepladders We provide solutions for: Bending / Driling / Punching / Riveting / Assembly Telescopic ladder Aluminium Stepladder Plastic Stepladder
FRM F1 M F11 F12. These units are meeting with Norms ISO and SAE. There is available a release type cartridge with a shorter installation length.
FRM A unidade FRM é uma bomba-motor com eixo em ângulo e deslocamento fixo, elaborado com um desenho de pistões de cabeça esférica. Confere-se um rendimento muito alto, seguindo os standards de montagem
RP13165 Impressa F50 platin (CH) 638 Edition: 23/04/09
The recycling passport is valid for the following articles: 13165 Impressa F50 platin (CH) 13166 Impressa F50 platin (EU) 13185 Impressa F7 platin (UL/JC) 13199 Impressa F55 platin (EU) 13201 Impressa
