Instructions AK-PC 551



Documentos relacionados
Instructions AK-PC 651

Instructions AK-PC 351

TM168B23S CONTROLADOR PROGRAMAVEL M168 SEM DISPLAY 23 E/S /S

Torre Purificadora de Ar MCP-

Digital Inputs and Outputs Expansion Kit Kit de Expansión de Entradas y Salidas Digitales Kit de Expansão de Entradas e Saídas Digitais

Manual do usuário. User s Manual JS052. Super band - guitarra sem fio PS2 / PS3 / Wii Super band - wireless guitar PS2 / PS3 / Wii

Física Experimental VI

User's Guide. Manual de Utilizador

EXEMPLO 1 DE CONTROLE DO ph ATUALMENTE EM USO NAS USINAS DE AÇÚCAR E ÁLCOOL

IDE 2.5" hd:basic. hdd enclosure caixa externa para disco rígido

Current Measurement Unit - UMC Unidad de Medición de Corriente - UMC Unidade de Medição de Corrente - UMC

Manual de instruções para Caixa Coletora Johnson Pump

Detecção de gás da Danfoss Módulo de expansão

Miniature Solenoid Valve Type 200

DALI TECHNOLOGY. Sistemas e Planeamento Industrial DOMÓTICA. Eng.º Domingos Salvador dos Santos.

Detecção de gás da Danfoss Unidade de controle

Boletim Técnico Abril / 2013

SONDA DE ÁGUA QUENTE SANITÁRIA

1 WC System. Instrução Técnica Instrucción Técnica Technical Instruction

SONDA CASCATA. Avisos preliminares CONTEÚDO FERRAMENTAS RECOMENDADAS NEXPOLAR

TM100C24RN Controller M100-14I/10O relay - 220VAC

Motor PTC Kit. Kit PTC del Motor. Kit PTC do Motor SSW-07 / SSW-08

Nome empresa: Criado por: Telefone:

LIGHT PANEL CONTENTS Light Panel Power supply Fixtures (brackets, screws)

RM4JA32M RELE DE MEDICAO E CONTROLE DE CORRENTE 2NANF A 220A2

MANUAL DE INSTRUÇÃO DO COMPRESSOR /COMPRESSOR INSTRUCTION MANUAL MARCA/BRAND GMCC MODELO/MODEL PH310G2C-3KUU

MANUAL DE INSTRUÇÃO DO COMPRESSOR /COMPRESSOR INSTRUCTION MANUAL MARCA/BRAND GMCC MODELO/MODEL PA291X3CS-3MTU

Manual do usuário. User s Manual. Music Bass subwoofer 4 em 1 SP101 Music Bass subwoofer 4 in 1 SP101. Music bass subwoofer 4 em 1

Operação de Instalações Marítimas

Motors Automation Energy Transmission & Distribution Coatings KPCSD - KPCSE CFW500

ÍNDICE PORTUGUÊS INDEX ENGLISH

ÍNDICE PORTUGUÊS INDEX ENGLISH

User Manual. Linksys PAP2 Broadband Phone Service. Linhagratuita grupo csdata

ABL8RPM24200 fonte chaveada regulada - monofásica ou bifásica V - 24 V - 20 A

Trabalho de AMSR. Especificação e Verificação de uma Câmara Fotográfica Digital. Problema a Resolver FEUP/MRSC/AMSR MPR. » Problema a concurso

Motors Automation Energy Transmission & Distribution Coatings. I/O Expansion Module NPN/ PNP Digital Inputs

Aula 22 - Revisão para a prova 2

AKV - Introdução FOOD RETAIL BRAZIL 1 / 38

RS-485 Kit. Kit RS-485. Kit RS-485. SSW-07 / SSW-08 English / Español / Português Document: / 04. Installation Guide. Guia de Instalación

Instructions AK-PC 551

APPLICATIONS USING TIME CONTROL EZC with remote clock switching off the installation during night times.

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

PRODUCT FAMILY DATASHEET SubstiTUBE PURE

Kit Tecsystem for MVW-01. Kit Tecsystem para MVW-01. Kit Tecsystem Installation, Configuration and Operation Guide

User Guide. Wiegand Reader AR-721U/ AR-721K/ AR-661U V060419

GEAR PUMPS RECOMMENDATIONS BEFORE START-UP

GV4 Hardware & Board Components

DATA SHEET Compact Genset Controller, CGC 400

Table of Contents. Lucas Nülle GmbH Página 1/15

Manual do usuário. Xperia TX TV Dock DK22 Xperia T TV Dock DK23 DK22/DK23

TWDLCAE40DRF CONTROLADOR PROGRAMAVEL 40 ES C ETHERNET

Table of Contents. Lucas Nülle GmbH Página 1/6

Manual do usuário. MHL to HDMI Adapter IM750

Arduino: primeiros passos para aprender e configurar.

TWDLCAA10DRF CONTROLADOR PROGRAMAVEL 6E DIGITAIS 4S RELE

TM200CE24R MODICON_EASY_M200 4_FAST_INPUT_I2...I5 4_HIGH_SPEED_INPUT_I0_I1_I6_I7 6_REGULAR_INPUT_I8...I13. 7 ma of entrada

Outdoor External Strobe Siren. ADD-ON DEVICE Quickstart Guide. What's inside: 1x Outdoor External Strobe Siren

Aula 12 - Correção de erros

NORMAS DE FUNCIONAMENTO DOS CURSOS DE LÍNGUAS (TURMAS REGULARES E INTENSIVAS) 2015/2016

BR localization: Hotfix 003. Technical documentation Documentação Técnica Version Dec 12, de Dezembro de 2018

Electronic Complements Second call exam 23 January 2013, 9-12 (Duration: 3 hours) MIEET 5º ano

SUMÁRIO PORTUGUÊS INDEX ENGLISH

ÍNDICE PORTUGUÊS INDEX ENGLISH

1. Product Name. 2. Product Code. 3. Colour. 4. Brief Description. 5. Contents. 6. Snoezelen Stimulations. Switch Adapted Fibre Optic Lamp

TM200C16R MODICON_EASY_M200 1_REGULAR_INPUT_I8 4_FAST_INPUT_I2...I5 4_HIGH_SPEED_INPUT_I0_I1_I6_I7. 7 ma of entrada

24-Port 10/100Mbps Web Smart PoE Switch with 4 Gigabit Ports and 2 Mini-GBIC Slots TPE-224WS ŸGuia de Instalação Rápida (1) ŸTroubleshooting (3)

FLOW Design by STUDIOP

Dados Técnicos. DADOS DE ENTRADA Fronius Galvo Potência CC máxima para cos φ=1. Máx. corrente de entrada. Min.

TWDLCAA24DRF CONTROLADOR PROGRAMAVEL 14 ENTRADAS 10 SAIDAS RELE

Motors Automation Energy Transmission & Distribution Coatings. Módulo de Expansión de I/O. Módulo de Expansão de I/O

Fernando ROCHA ABB Brasil Marketing Control 2015 Relé Inteligente UMC100.3 Produtividade e Eficiência para o seu Processo

User Guide Manual de Utilizador

INSTRUÇÕES DE INSTALAÇÃO

WEG CFW-08 DRIVES - ONLINE PRICE LIST 2014

Relé Inteligente UMC Automation World

BMXART0414 MODULO X80-4 ENTRADAS ANALOGICAS - RTD/TERMOPAR - 16BIT

hdd enclosure caixa externa para disco rígido

Transcrição:

Instructions AK-PC 551 Identification 1,5 m: 080G0075 3,0 m: 080G0076 080G0281 = 230 V a.c. 20 VA 080G0283 = 24 V a.c. / d.c. 17 VA 080G0321 = 230 V a.c. 20 VA 080G0326 = 24 V a.c. / d.c. 17 VA MMIGRS2: 080G0294 Kit 080G0282 = 080G0321 + 080G0294 + 080G0075 (230 V) 080G0288 = 080G0326 + 080G0294 + 080G0075 (24 V) 1,5 m IP 20-20 - 60 C (0-140 F) RH max. 90% non condensing Principle RI8PZ3ML 09-2014

ENGLISH Connection, lower level Connection, upper level DO DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 Σ 1-8 I Max. U All 24 V or all 230 V a.c. 32 A Supply Voltage The supply voltage is either 24 V or 110-230 V. See the label on the reverse side of the controller. Plugs normally not used However, if connecting to an external display, a jumper must be inserted between the connections "H" and "R". Modbus It is important that the installation of the data communication cable be done correctly. Cf. separate literature No. RC8AC. Remember termination at the bus termination. DO - Digital outputs, 8 pcs. DO1 - DO8 DO5 and DO6 are solid state relays. The relays are de-rated to the specified values. If an alarm relay is defined, it will be driven under normal operation and it will drop in the event of alarms and insufficient power to the controller. AO - Analogue output, 2 pcs. AO3 - AO4 Must be used when using a frequency converter or EC motors. Connect 24 V on N and L and obtain 0-10 volts from terminals N-3 and N-4. PAY ATTENTION TO THE POLARITY of N. AI - Analogue inputs, 4 pcs. AI1 - AI4 Pressure transmitters Ratiometric: 10-90% of supply, AKS 32R Signal: 1-5 V, AKS 32 Current: 0-20 ma / 4-20 ma, AKS 33 Temperature sensor Pt 1,000 ohm, AKS 11 or AKS 21. NTC 86K ohm @ 25 C, from digital scroll. Factory settings AI1=PoA, AI2=PoB, AI3=Pc, AI4=Outdoor temperature SC3. DI - Digital switch inputs, 8 pcs. DI1 - DI8 The connection may be a shut-down or interruption function. Select what is to be activated during configuration. AKS 32R Plugs normally not used - AKS 32 AKS 33 AI - Analogue inputs, 4 pcs. AI5 - AI8 Pressure transmitters Ratiometric: 10-90% of supply, AKS 32R Signal: 1-5 V, AKS 32 Temperature sensor Pt 1,000 ohm, AKS 11 or AKS 21. NTC 86K ohm @ 25 C, from digital scroll 2 Instructions RI8PZ3ML Danfoss 09/2014 AK-PC 551

External display Dimensions! The capacity from the digital scroll compressor Only DO5 or DO6 The capacity is divided into period times as "PWM period time". 100% capacity is delivered when cooling takes place for the whole period. An off time is required by the capacity control valve within the period and an on time is also permitted. There is "no cooling" when the valve is on. The controller itself calculates the capacity needed and will then vary it according to the cut-in time of the capacity control valve. A limit is introduced if low capacity is needed so that the cooling does not go below 10%. This is because the compressor can cool itself. This value can be increased if necessary. Refrigeration / No refrigeration Min. capacity Period time Copeland Stream compressor The signal can also be used to control one stream compressor with one unloading valve (4 cylinders version). The compressor capacity is distributed by up to 50% for one relay and the remaining 50-100% for the unloader. The unloader is connected to DO5 or DO6. Bitzer CRII The pulse signal can also be used to control one of the CRII with 2 unloaders (4 cylinders version). Compressor capacity can be controlled from 10 to 100% depending on the pulsation of the unloaders. The unloader is connected to DO5 or DO6. Unloader 1 Unloader 2 follows unloader 1 but is offset a ½ period. Unloader 2 AK-PC 551 Instructions RI8PZ3ML Danfoss 09/2014 3

Português Conexão, nível inferior Conexão, nível superior DO DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 Σ 1-8 I Max. U Tudo 24 V ou tudo 230 V CA 32 A Tensão de alimentação A tensão de alimentação é de 24 V ou de 110-230 V. Consulte a etiqueta no reverso do controlador. Normalmente não são utilizados plugues Entretanto, no caso de conectar com um display externo, um jumper deverá ser inserido entre as duas conexões "H" e "R". Modbus É importante que a instalação do cabo de comunicação de dados seja efetuada corretamente. Consulte a literatura separada nº RC8AC. Lembre-se: terminação na terminação do barramento. DO - Saídas digitais, 8 pçs. DO1 - DO8 DO5 e DO6 são relés de estado sólido. Os relés são derated aos valores especificados. Caso um relé de alarme seja definido, ele será acionado durante a operação normal e desarmará em caso de alarmes e de tensão insuficiente para o controlador. AO - Saída analógica, 2 pçs. AO3 - AO4 Deverão ser utilizadas ao usar um conversor de frequência ou motores EC. Conecte 24 V em N e L e obtenha 0-10 volts dos terminais N-3 e N-4. PRESTE ATENÇÃO À POLARIDADE de N. AI - Entradas analógicas, 4 pçs. AI1 - AI4 Pressostatos Raciométrico: 10-90% do fornecimento, AKS 32R Sinal: 1-5 V, AKS 32 Corrente: 0-20 ma / 4-20 ma, AKS 33 Sensor de temperatura Pt 1.000 ohm, AKS 11 or AKS 21. NTC 86K ohm a 25 C, da rolagem digital. Definições de fábrica AI1=PoA, AI2=PoB, AI3=Pc, AI4=Temperatura externa SC3. DI - Entradas de interruptores digitais, 8 pçs. DI1 - DI8 A conexão pode ser um desligamento ou função de interrupção. Selecione o que deverá ser ativado durante a configuração. AKS 32R Normalmente não são utilizados plugues - AKS 32 AKS 33 AI - Entradas analógicas, 4 pçs. AI5 - AI8 Pressostatos Raciométrico: 10-90% do fornecimento, AKS 32R Sinal: 1-5 V, AKS 32 Sensor de temperatura Pt 1.000 ohm, AKS 11 or AKS 21. NTC 86K ohm a 25 C, da rolagem digital 4 Instructions RI8PZ3ML Danfoss 09/2014 AK-PC 551

Display externo Dimensões! A capacidade do compressor de rolagem digital Somente para DO5 ou DO6 A capacidade é dividida em períodos de tempo. É fornecida 100% da capacidade quando o resfriamento acontece durante todo o período. Um tempo desligado é necessário para a válvula de controle de capacidade, dentro do período e um tempo ligado também é permitido. Não há resfriamento quando a válvula estiver ligada. O controlador por si próprio calcula a capacidade necessária e então irá variá-la de acordo com o tempo de ligar da válvula de controle de capacidade. Um limite é introduzido se uma baixa capacidade for necessária de modo que o resfriamento não caia para baixo de 10%. Isto é porque o compressor pode resfriar-se a si próprio. Esse valor poderá ser aumentado, se necessário. Refrigeração / Não há refrigeração Min. Capacidad Período de tempo Copeland Compressor de fluxo O sinal de também pode ser usado para controlar um compressor de fluxo com 1 válvula de alívio de pressão (versão com 4 cilindros). A capacidade do compressor é distribuída por até 50% para um relé e os restantes 50-100% para o descarregador. O descarregador está conectado em DO5 ou DO6. Bitzer CRII O sinal de pulso também pode ser utilizado para controlar um dos CRII com 2 descarregadores (versão com 4 cilindros). A capacidade do compressor pode ser controlada de 10 a 100%, dependendo da pulsação dos descarregadores. O descarregador está ligado a DO5 ou DO6. Descarregador 1 O descarregador 2 segue o descarregador 1, mas tem ½ período de deslocamento. Descarregador 2 AK-PC 551 Instructions RI8PZ3ML Danfoss 09/2014 5

The Product contains electrical components And may not be disposed together with domestic waste. Equipment must be separate collected with Electrical and Electronic waste. According to Local and currently valid legislation. ADAP-KOOL 6 Instructions RI8PZ3ML Danfoss 09/2014 AK-PC 551